drm/bridge: Clear the DP_AUX_I2C_MOT bit passed in aux read command.
Subsystems (3)
PATCH v2 1/1 drm/bridge: Clear the DP_AUX_I2C_MOT bit passed in aux read command.
If the previous transfer didn't end with a command without DP_AUX_I2C_MOT, the next read trasnfer will miss the first byte. But if the command in previous transfer is requested with length 0, it's a no-op to anx7625 since it can't process this command. anx7625 requires the last command to be read command with length > 0.
It's observed that if we clear the DP_AUX_I2C_MOT in read transfer, we can still get correct data. Clear the read commands with DP_AUX_I2C_MOT bit to fix this issue.
---v1->v2: Offline discussed with Xin Ji, it's better to clear the bit on read commands only.
--- drivers/gpu/drm/bridge/analogix/anx7625.c | 2 ++ 1 file changed, 2 insertions(+)
drivers/gpu/drm/bridge/analogix/anx7625.c +2 -0
@@ -253,6 +253,8 @@ static int anx7625_aux_trans(struct anx7625_data *ctx, u8 op, u32 address, addrm = (address >>8 ) &0xFF ; addrh = (address >>16 ) &0xFF ; +if (!is_write) + op &= ~DP_AUX_I2C_MOT ; cmd =DPCD_CMD (len, op);/* Set command and length */
Signature · 1 line
2.35.1.265.g69c8d7142f-goog
Quoted 9 lines · Hsin-Yi Wang
If the previous transfer didn't end with a command without
DP_AUX_I2C_MOT, the next read trasnfer will miss the first byte. But if the command in previous transfer is requested with length 0, it's a no-op to anx7625 since it can't process this command. anx7625 requires the last command to be read command with length > 0.It's observed that if we clear the
DP_AUX_I2C_MOTin read transfer, we can still get correct data. Clear the read commands withDP_AUX_I2C_MOTbit to fix this issue.
Hi Hsin-Yi, thanks for the patch!
Thanks,
Xin
Quoted 25 lines
Fixes adca62ec370c ("drm/bridge: anx7625: Support reading edid through aux channel")Signed-off-by Hsin-Yi Wang <[email protected]>---
v1->v2: Offline discussed with Xin Ji, it's better to clear the bit on read commands only.--- drivers/gpu/drm/bridge/analogix/anx7625.c | 2 ++ 1 file changed, 2 insertions(+)drivers/gpu/drm/bridge/analogix/anx7625.c +2
-0@@ -253,6 +253,8 @@ static int anx7625_aux_trans(struct anx7625_data *ctx, u8 op, u32 address, addrm = (address >>8 ) &0xFF ; addrh = (address >>16 ) &0xFF ; +if (!is_write) + op &= ~DP_AUX_I2C_MOT ; cmd =DPCD_CMD (len, op);/* Set command and length */ Signature · 1 line
2.35.1.265.g69c8d7142f-goog
Quoted 12 lines · Xin Ji
Quoted 9 lines · Hsin-Yi Wang
If the previous transfer didn't end with a command without
DP_AUX_I2C_MOT, the next read trasnfer will miss the first byte. But if the command in previous transfer is requested with length 0, it's a no-op to anx7625 since it can't process this command. anx7625 requires the last command to be read command with length > 0.It's observed that if we clear the
DP_AUX_I2C_MOTin read transfer, we can still get correct data. Clear the read commands withDP_AUX_I2C_MOTbit to fix this issue.
Quoted 6 lines
Hi Hsin-Yi, thanks for the patch!
Reviewed-by Xin Ji <[email protected]>Thanks,
Xin
Hi Robert,
Kindly ping on this fix. Thanks.
Quoted 25 lines
Quoted 25 lines
Fixes adca62ec370c ("drm/bridge: anx7625: Support reading edid through aux channel")Signed-off-by Hsin-Yi Wang <[email protected]>---
v1->v2: Offline discussed with Xin Ji, it's better to clear the bit on read commands only.--- drivers/gpu/drm/bridge/analogix/anx7625.c | 2 ++ 1 file changed, 2 insertions(+)drivers/gpu/drm/bridge/analogix/anx7625.c +2
-1@@ -253,6 +253,8 @@ static int anx7625_aux_trans(struct anx7625_data *ctx, u8 op, u32 address, addrm = (address >>8 ) &0xFF ; addrh = (address >>16 ) &0xFF ; +if (!is_write) + op &= ~DP_AUX_I2C_MOT ; cmd =DPCD_CMD (len, op);/* Set command and length */ --2.35.1.265.g69c8d7142f-goog
Robert Foss
AppliedApplied to drm-misc-next.