hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk 360

PATCH New Aleksa Savic 1 participant 1 message Feb 27, 2022

Subsystems (3)
lore
Share & tools
lore

Aleksa Savic

author maintainer
#0 lore raw

PATCH v4 1/1 hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk 360

Extend aquacomputer_d5next driver to expose hardware temperature sensors of the Aquacomputer Farbwerk 360 RGB controller, which communicates through a proprietary USB HID protocol.

Four temperature sensors are available. Additionally, serial number and firmware version are exposed through debugfs.

This driver has been tested on x86_64.

---
Changes in v4:
- Fix formatting issues

Changes in v3:
- Reformatted channel info and array holding device names
- Shortened prefix of methods and structs to aqc

Changes in v2:
- Extended the existing aquacomputer_d5next driver instead of creating a new one and extended docs
- Moved asm include to the end
- Report ENODATA if sensor is disconnected instead of 0 degrees

---
 Documentation/hwmon/aquacomputer_d5next.rst |  49 ++-
 drivers/hwmon/aquacomputer_d5next.c         | 379 +++++++++++++-------
 2 files changed, 278 insertions(+), 150 deletions(-)
Documentation/hwmon/aquacomputer_d5next.rst +23 -26
index 1f4bb4ba2e4b..3373e27b707d 100644
@@ -6,22 +6,21 @@ Kernel driver aquacomputer-d5next
 Supported devices:
 
 * Aquacomputer D5 Next watercooling pump
+* Aquacomputer Farbwerk 360 RGB controller
 
 Author: Aleksa Savic
 
 Description
 -----------
 
-This driver exposes hardware sensors of the Aquacomputer D5 Next watercooling
-pump, which communicates through a proprietary USB HID protocol.
+This driver exposes hardware sensors of listed Aquacomputer devices, which
+communicate through proprietary USB HID protocols.
 
-Available sensors are pump and fan speed, power, voltage and current, as
-well as coolant temperature. Also available through debugfs are the serial
-number, firmware version and power-on count.
-
-Attaching a fan is optional and allows it to be controlled using temperature
-curves directly from the pump. If it's not connected, the fan-related sensors
-will report zeroes.
+For the D5 Next pump, available sensors are pump and fan speed, power, voltage
+and current, as well as coolant temperature. Also available through debugfs are
+the serial number, firmware version and power-on count. Attaching a fan to it is
+optional and allows it to be controlled using temperature curves directly from the
+pump. If it's not connected, the fan-related sensors will report zeroes.
 
 The pump can be configured either through software or via its physical
 interface. Configuring the pump through this driver is not implemented, as it
@@ -29,33 +28,31 @@ seems to require sending it a complete configuration. That includes addressable
 RGB LEDs, for which there is no standard sysfs interface. Thus, that task is
 better suited for userspace tools.
 
+The Farbwerk 360 exposes four temperature sensors. Depending on the device,
+not all sysfs and debugfs entries will be available.
+
 Usage notes
 -----------
 
-The pump communicates via HID reports. The driver is loaded automatically by
+The devices communicate via HID reports. The driver is loaded automatically by
 the kernel and supports hotswapping.
 
 Sysfs entries
 -------------
 
-============ =============================================
-temp1_input  Coolant temperature (in millidegrees Celsius)
-fan1_input   Pump speed (in RPM)
-fan2_input   Fan speed (in RPM)
-power1_input Pump power (in micro Watts)
-power2_input Fan power (in micro Watts)
-in0_input    Pump voltage (in milli Volts)
-in1_input    Fan voltage (in milli Volts)
-in2_input    +5V rail voltage (in milli Volts)
-curr1_input  Pump current (in milli Amperes)
-curr2_input  Fan current (in milli Amperes)
-============ =============================================
+================ =============================================
+temp[1-4]_input  Temperature sensors (in millidegrees Celsius)
+fan[1-2]_input   Pump/fan speed (in RPM)
+power[1-2]_input Pump/fan power (in micro Watts)
+in[0-2]_input    Pump/fan voltage (in milli Volts)
+curr[1-2]_input  Pump/fan current (in milli Amperes)
+================ =============================================
 
 Debugfs entries
 ---------------
 
-================ ===============================================
-serial_number    Serial number of the pump
+================ =================================================
+serial_number    Serial number of the device
 firmware_version Version of installed firmware
-power_cycles     Count of how many times the pump was powered on
-================ ===============================================
+power_cycles     Count of how many times the device was powered on
+================ =================================================
drivers/hwmon/aquacomputer_d5next.c +255 -124

564 lines not on this page · raw message

Signature · 1 line
2.35.1