RFC Jagath Jog J 2 participants 2 messages Mar 17, 2022 – Mar 18, 2022 IIO

lore
Share & tools
lore
#0 lore raw

Hello,

To continue the contribution I chose the bma400 accelerometer device driver, there are multiple todos, so thought of adding support for the same. Currently, I am able to get the trigger buffer with data ready interrupt, step counter and event for step change with bma400 accelero breakout board.

Below are the changes I have implemented for the bma400 driver in separate patches

1. Conversion to device-managed function and remove the bma400_remove() function.
2. Added trigger buffer support with data ready interrupt.
3. Added a separate channel for the step counter.
4. Added event support for step change.

Can I send the above patches for review?
Sorry for all the mistakes that I have made in the previous ds1803 patch series and I will make sure to avoid all those mistakes.

In the bma400 driver, I am stuck on one point and your advice will be very helpful.

https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-bus-iio
From IIO documentation for accelerometer device the calculation for final value from the sysfs attributes of the accelerometer device for the Z-axis will be
(in_accel_z_raw + in_accel_z_offset) * in_accel_scale = 9.8 m/s2 approximately.

In the mainline kernel bma400 device driver, there are multiple-scale values for different acceleration ranges +-2g, +-4g, etc.

root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale_available
0.038357 0.076714 0.153428 0.306856

With +-4g range root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale
0.076714 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_z_raw
519 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo "0.076714 * 506" | bc
39.277568

With +- 2g range root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo 0.038357 > in_accel_scale root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale
0.038357 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_z_raw
1012 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo "0.038357 * 1012" | bc
38.817284

The _raw value from the sensor is as per the datasheet but the final value for the Z axis after applying scale for all ranges is around 38.8 which is not expected. I tried by placing the sensor in a different position where the X-axis value should be approximately 9.8 m/s2 but In this case also the value is around 38.8 m/s2

Is the above method to calculate the acceleration in the Z-axis correct or am I missing something?

For confirmation I also tested the mpu6050 IMU.

root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_scale_available
0.000598 0.001196 0.002392 0.004785
root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_scale
0.000598
root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_z_raw
16706
root@raspberrypi:/sys/bus/iio/devices/iio:device1# echo "0.000598 * 16706" | bc
9.9801
With MPU6050 I am getting 9.9801 m/s2 which is near to earth's acceleration due
to gravity 9.8 m/s2

For BMA400 I recalculated the scale values from sensitivity for different acceleration ranges
https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bma400-ds000.pdf

For +-2g - 1 LSB = 0.0095768 m/s2
For +-4g - 1 LSB = 0.0191536 m/s2
For +-4g - 1 LSB = 0.0383072 m/s2
Is the above method to calculate the scale values correct or am I missing something?

Thank you
Jagath

#1 lore raw
Quoted 6 lines · Jagath Jog J

Hello,

To continue the contribution I chose the bma400 accelerometer device driver, there are multiple todos, so thought of adding support for the same. Currently, I am able to get the trigger buffer with data ready interrupt, step counter and event for step change with bma400 accelero breakout board.

This is awesome! Thanks so much for checking out the driver. I enjoyed writing it. It seems like quite a capable device with lots of features I've yet to implement, and I had far less time free for development on the device than I had hoped. Any help would be _greatly_ appreciated.

Quoted 9 lines

Below are the changes I have implemented for the bma400 driver in separate patches

1. Conversion to device-managed function and remove the bma400_remove() function.
2. Added trigger buffer support with data ready interrupt.
3. Added a separate channel for the step counter.
4. Added event support for step change.
Can I send the above patches for review?

I used the driver for this device as a way to learn, so I by no means claim to be an expert, but I'll do my best to review and test patches sent. At a bare minimum I can be a shoulder to cry on and fellow to commiserate with :-)

Quoted 43 lines

Sorry for all the mistakes that I have made in the previous ds1803 patch series and I will make sure to avoid all those mistakes.

In the bma400 driver, I am stuck on one point and your advice will be very helpful.

https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-bus-iio
From IIO documentation for accelerometer device the calculation for final value from the sysfs attributes of the accelerometer device for the Z-axis will be
(in_accel_z_raw + in_accel_z_offset) * in_accel_scale = 9.8 m/s2 approximately.

In the mainline kernel bma400 device driver, there are multiple-scale values for different acceleration ranges +-2g, +-4g, etc.

root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale_available
0.038357 0.076714 0.153428 0.306856

With +-4g range root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale
0.076714 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_z_raw
519 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo "0.076714 * 506" | bc
39.277568

With +- 2g range root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo 0.038357 > in_accel_scale root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_scale
0.038357 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# cat in_accel_z_raw
1012 root@raspberrypi:/sys/devices/platform/soc/3f804000.i2c/i2c-1/1-0014/iio:device0# echo "0.038357 * 1012" | bc
38.817284

Quoted 7 lines

The _raw value from the sensor is as per the datasheet but the final value for the Z axis after applying scale for all ranges is around 38.8 which is not expected. I tried by placing the sensor in a different position where the X-axis value should be approximately 9.8 m/s2 but In this case also the value is around 38.8 m/s2

Is the above method to calculate the acceleration in the Z-axis correct or am I missing something?

Based on your tests, a review of the code, and a re-read of the datasheet, I definitely calculated the BMA400_SCALE_MIN and BMA400_SCALE_MAX incorrectly.

Quoted 13 lines

For confirmation I also tested the mpu6050 IMU.

root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_scale_available
0.000598 0.001196 0.002392 0.004785
root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_scale
0.000598
root@raspberrypi:/sys/bus/iio/devices/iio:device1# cat in_accel_z_raw
16706
root@raspberrypi:/sys/bus/iio/devices/iio:device1# echo "0.000598 * 16706" | bc
9.9801
With MPU6050 I am getting 9.9801 m/s2 which is near to earth's acceleration due
to gravity 9.8 m/s2
Quoted 7 lines

For BMA400 I recalculated the scale values from sensitivity for different acceleration ranges
https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bma400-ds000.pdf

For +-2g - 1 LSB = 0.0095768 m/s2
For +-4g - 1 LSB = 0.0191536 m/s2
For +-4g - 1 LSB = 0.0383072 m/s2

Assuming you mean 8g for the last one here.

Quoted 2 lines

Is the above method to calculate the scale values correct or am I missing something?

Yeah, the scale is definitely off currently.

I think we need to change the following, if I'm reading the datasheet correctly.

- BMA400_SCALE_MIN to 9582
- BMA400_SCALE_MAX to 76659

Great catch and thanks for working on the device!

Quoted 2 lines

Thank you
Jagath

Cheers,

- Dan