Skip to contentSkip to conversation

acpi/battery: Make "not-charging" the default on no charging or full info

PATCH Applied Werner Sembach 2 participants 2 messages Apr 27, 2022 – May 6, 2022 ACPI

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 acpi/battery: Make "not-charging" the default on no charging or full info

When the battery is neither charging or discharging and is not full, "not-charging" is a useful status description for the case in general. Currently this state is set as "unknown" by default, expect when this is explicitly replaced with "not-charging" on a per device or per vendor basis.

A lot of devices have this state without a BIOS specification available explicitly describing it. e.g. some current Clevo barebones have a BIOS setting to stop charging at a user defined battery level.

---
 drivers/acpi/battery.c | 24 +-----------------------
 1 file changed, 1 insertion(+), 23 deletions(-)
drivers/acpi/battery.c +1 -23
index dc208f5f5a1f..306513fec1e1 100644
@@ -52,7 +52,6 @@ static bool battery_driver_registered;
 static int battery_bix_broken_package;
 static int battery_notification_delay_ms;
 static int battery_ac_is_broken;
-static int battery_quirk_notcharging;
 static unsigned int cache_time = 1000;
 module_param(cache_time, uint, 0644);
 MODULE_PARM_DESC(cache_time, "cache time in milliseconds");
@@ -216,10 +215,8 @@ static int acpi_battery_get_property(struct power_supply *psy,
 			val->intval = POWER_SUPPLY_STATUS_CHARGING;
 		else if (acpi_battery_is_charged(battery))
 			val->intval = POWER_SUPPLY_STATUS_FULL;
-		else if (battery_quirk_notcharging)
-			val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
 		else
-			val->intval = POWER_SUPPLY_STATUS_UNKNOWN;
+			val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
 		break;
 	case POWER_SUPPLY_PROP_PRESENT:
 		val->intval = acpi_battery_present(battery);
@@ -1105,12 +1102,6 @@ battery_ac_is_broken_quirk(const struct dmi_system_id *d)
 	return 0;
 }
 
-static int __init battery_quirk_not_charging(const struct dmi_system_id *d)
-{
-	battery_quirk_notcharging = 1;
-	return 0;
-}
-
 static const struct dmi_system_id bat_dmi_table[] __initconst = {
 	{
 		/* NEC LZ750/LS */
@@ -1139,19 +1130,6 @@ static const struct dmi_system_id bat_dmi_table[] __initconst = {
 			DMI_MATCH(DMI_BIOS_DATE, "08/22/2014"),
 		},
 	},
-	{
-		/*
-		 * On Lenovo ThinkPads the BIOS specification defines
-		 * a state when the bits for charging and discharging
-		 * are both set to 0. That state is "Not Charging".
-		 */
-		.callback = battery_quirk_not_charging,
-		.ident = "Lenovo ThinkPad",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "LENOVO"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "ThinkPad"),
-		},
-	},
 	{
 		/* Microsoft Surface Go 3 */
 		.callback = battery_notification_delay_quirk,
Signature · 1 line
2.25.1
maintainer Applied
#1 lore raw
Quoted 64 lines · Werner Sembach

When the battery is neither charging or discharging and is not full, "not-charging" is a useful status description for the case in general. Currently this state is set as "unknown" by default, expect when this is explicitly replaced with "not-charging" on a per device or per vendor basis.

A lot of devices have this state without a BIOS specification available explicitly describing it. e.g. some current Clevo barebones have a BIOS setting to stop charging at a user defined battery level.

---
 drivers/acpi/battery.c | 24 +-----------------------
 1 file changed, 1 insertion(+), 23 deletions(-)
drivers/acpi/battery.c +1 -17
index dc208f5f5a1f..306513fec1e1 100644
@@ -52,7 +52,6 @@ static bool battery_driver_registered;
 static int battery_bix_broken_package;
 static int battery_notification_delay_ms;
 static int battery_ac_is_broken;
-static int battery_quirk_notcharging;
 static unsigned int cache_time = 1000;
 module_param(cache_time, uint, 0644);
 MODULE_PARM_DESC(cache_time, "cache time in milliseconds");
@@ -216,10 +215,8 @@ static int acpi_battery_get_property(struct power_supply *psy,
                        val->intval = POWER_SUPPLY_STATUS_CHARGING;
                else if (acpi_battery_is_charged(battery))
                        val->intval = POWER_SUPPLY_STATUS_FULL;
-               else if (battery_quirk_notcharging)
-                       val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
                else
-                       val->intval = POWER_SUPPLY_STATUS_UNKNOWN;
+                       val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
                break;
        case POWER_SUPPLY_PROP_PRESENT:
                val->intval = acpi_battery_present(battery);
@@ -1105,12 +1102,6 @@ battery_ac_is_broken_quirk(const struct dmi_system_id *d)
        return 0;
 }
 
-static int __init battery_quirk_not_charging(const struct dmi_system_id *d)
-{
-       battery_quirk_notcharging = 1;
-       return 0;
-}
-
 static const struct dmi_system_id bat_dmi_table[] __initconst = {
        {
                /* NEC LZ750/LS */
@@ -1139,19 +1130,6 @@ static const struct dmi_system_id bat_dmi_table[] __initconst = {
                        DMI_MATCH(DMI_BIOS_DATE, "08/22/2014"),
                },
        },
-       {
-               /*
-                * On Lenovo ThinkPads the BIOS specification defines
-                * a state when the bits for charging and discharging
-                * are both set to 0. That state is "Not Charging".
-                */
-               .callback = battery_quirk_not_charging,

drivers/acpi/battery.c static const struct dmi_system_id bat_dmi_table[] __initconst = {

Quoted 10 lines
drivers/acpi/battery.c +0 -7
-               .ident = "Lenovo ThinkPad",
-               .matches = {
-                       DMI_MATCH(DMI_SYS_VENDOR, "LENOVO"),
-                       DMI_MATCH(DMI_PRODUCT_VERSION, "ThinkPad"),
-               },
-       },
        {
                /* Microsoft Surface Go 3 */
                .callback = battery_notification_delay_quirk,
--

Applied as 5.19 material, thanks!