tests/i915/kms_cdclk: Fixed mode selection for extended mode tests
PATCH 1/2 tests/i915/kms_cdclk: Fixed mode selection for extended mode tests
Added check on ENOSPC and EINVAL when two moniters connected through MST. This will find the connector mode combo that fits into the bandwidth when more than one monitor is connected.
Example:
When two monitors connected through MST, the second monitor also tries to use the same mode. So two such modes may not fit into the link bandwidth. So, iterate through connected outputs & modes and find a combination of modes those fit into the link BW.
Signed-off-by Mohammed Thasleem <[email protected]>
--- tests/i915/kms_cdclk.c | 11 +++++++++++ 1 file changed, 11 insertions(+)
tests/i915/kms_cdclk.c +11 -0
@@ -313,7 +313,18 @@ static void test_mode_transition_on_all_outputs(data_t *data) j++; } +/* In case of DP-MST find suitable mode(s) to fit into the link BW. */ +if ((igt_display_try_commit_atomic (display, +DRM_MODE_ATOMIC_ALLOW_MODESET , +NULL ) !=0 ) && (errno ==EINVAL + || errno ==ENOSPC )) { +bool found =igt_override_all_active_output_modes_to_fit_bw (display); + +igt_require_f (found,"No valid mode combo found.\n" ); + } +igt_display_commit2 (display,COMMIT_ATOMIC ); + cdclk_new =get_current_cdclk_freq (debugfs_fd);igt_info ("CD clock frequency %d -> %d\n" , cdclk_ref, cdclk_new);
Signature · 1 line