thermal: imx8mm_thermal: wait for a valid measurement
Subsystems (2)
PATCH 1/1 thermal: imx8mm_thermal: wait for a valid measurement
Check if first measurement is still pending or if temperature is out of range.
Return and try again later if that is the case.
Fixes 5eed800a6811 ("thermal: imx8mm: Add support for i.MX8MM thermal monitoring unit")
Signed-off-by Marcus Folkesson <[email protected]>
--- drivers/thermal/imx8mm_thermal.c | 10 ++++++++-- 1 file changed, 8 insertions(+), 2 deletions(-)
drivers/thermal/imx8mm_thermal.c +8 -2
@@ -62,9 +62,15 @@ static int imx8mm_tmu_get_temp(void *data, int *temp) {struct tmu_sensor *sensor = data;struct imx8mm_tmu *tmu = sensor->priv; -u32 val; +bool ready; +unsigned long val; + + val =readl_relaxed (tmu->base +TRITSR ); + ready =test_bit (probe_status_offset (1 ), &val); +if (!ready) +return -EAGAIN ; - val =readl_relaxed (tmu->base +TRITSR ) &TRITSR_TEMP0_VAL_MASK ; + val = val &TRITSR_TEMP0_VAL_MASK ; *temp = val *1000 ;if (*temp <VER1_TEMP_LOW_LIMIT )return -EAGAIN ;
Signature · 1 line
2.37.1