hwmon: (pmbus/core): Implement regulator get_status
PATCH v3 1/1 hwmon: (pmbus/core): Implement regulator get_status
From: Patrick Rudolph <[email protected]>
Add get_status for pmbus_regulator_ops.
Changes:
- use lock throughout the function
- Avoid line continuation upto 100 column
- Optimize use of & and | operator
- Check for VOUT, IOUT, TEMPERATURE bit in status word before checking respective status register for fault.
- Report regulator current status.
--- drivers/hwmon/pmbus/pmbus_core.c | 88 ++++++++++++++++++++++++++++++++ 1 file changed, 88 insertions(+)
drivers/hwmon/pmbus/pmbus_core.c +88 -0
@@ -2851,6 +2851,93 @@ static int pmbus_regulator_get_error_flags(struct regulator_dev *rdev, unsignedreturn 0 ; } +static int pmbus_regulator_get_status (struct regulator_dev *rdev) +{ +struct device *dev =rdev_get_dev (rdev); +struct i2c_client *client =to_i2c_client (dev->parent); +struct pmbus_data *data =i2c_get_clientdata (client); +u8 page =rdev_get_id (rdev); +int status, status2, ret; + +mutex_lock (&data->update_lock); + status =pmbus_get_status (client, page,PMBUS_STATUS_WORD ); +if (status <0 ) { + ret = status; + goto unlock; + } + +if (status &PB_STATUS_OFF ) { + ret =REGULATOR_STATUS_OFF ; + goto unlock; + } + +/* If regulator is ON & reports power good then return ON */ +if (!(status &PB_STATUS_POWER_GOOD_N )) { + ret =REGULATOR_STATUS_ON ; + goto unlock; + } + +if (status & (PB_STATUS_VIN_UV |PB_STATUS_IOUT_OC |PB_STATUS_VOUT_OV | +PB_STATUS_UNKNOWN )){ + ret =REGULATOR_STATUS_ERROR ; + goto unlock; + } + +if (status &PB_STATUS_VOUT && data->info->func[page] &PMBUS_HAVE_STATUS_VOUT ) { + status2 =_pmbus_read_byte_data (client, page, +PMBUS_STATUS_VOUT ); +if (status2 <0 ) { + ret = status2; + goto unlock; + } +if (status2 & (PB_VOLTAGE_OV_FAULT |PB_VOLTAGE_UV_FAULT )) { + ret =REGULATOR_STATUS_ERROR ; + goto unlock; + } + } + +if (status &PB_STATUS_IOUT_POUT && data->info->func[page] &PMBUS_HAVE_STATUS_IOUT ) { + status2 =_pmbus_read_byte_data (client, page,PMBUS_STATUS_IOUT ); +if (status2 <0 ) { + ret = status2; + goto unlock; + } +if (status2 & (PB_POUT_OP_FAULT |PB_IOUT_UC_FAULT |PB_IOUT_OC_LV_FAULT | +PB_IOUT_OC_FAULT )) { + ret =REGULATOR_STATUS_ERROR ; + goto unlock; + } + } + +if (status &PB_STATUS_INPUT && data->info->func[page] &PMBUS_HAVE_STATUS_INPUT ) { + status2 =_pmbus_read_byte_data (client, page,PMBUS_STATUS_INPUT ); +if (status2 <0 ) { + ret = status2; + goto unlock; + } +if (status2 & (PB_IIN_OC_FAULT |PB_VOLTAGE_OV_FAULT |PB_VOLTAGE_UV_FAULT )) { + ret =REGULATOR_STATUS_ERROR ; + goto unlock; + } + } + +if (status &PB_STATUS_TEMPERATURE && data->info->func[page] &PMBUS_HAVE_STATUS_TEMP ) { + status2 =_pmbus_read_byte_data (client, page,PMBUS_STATUS_TEMPERATURE ); +if (status2 <0 ) { + ret = status2; + goto unlock; + } +if (status2 & (PB_TEMP_UT_FAULT |PB_TEMP_OT_FAULT )) { + ret =REGULATOR_STATUS_ERROR ; + goto unlock; + } + } + +unlock: +mutex_unlock (&data->update_lock); +return ret; +} +static int pmbus_regulator_get_low_margin (struct i2c_client *client,int page) {struct pmbus_data *data =i2c_get_clientdata (client);
@@ -2991,6 +3078,7 @@ const struct regulator_ops pmbus_regulator_ops = { .disable = pmbus_regulator_disable, .is_enabled = pmbus_regulator_is_enabled, .get_error_flags = pmbus_regulator_get_error_flags, + .get_status = pmbus_regulator_get_status, .get_voltage = pmbus_regulator_get_voltage, .set_voltage = pmbus_regulator_set_voltage, .list_voltage = pmbus_regulator_list_voltage,
base-commit: 27fea302952d8c90cafbdbee96bafeca03544401
Signature · 1 line
2.37.3
Guenter Roeck
maintainerQuoted 4 lines · Naresh Solanki
From: Patrick Rudolph <[email protected]>
Add
get_statusforpmbus_regulator_ops.
Quoted 8 lines
Changes:
- use lock throughout the function
- Avoid line continuation upto 100 column
- Optimize use of & and | operator
- Check for VOUT, IOUT, TEMPERATURE bit in status word before checking respective status register for fault.
- Report regulator current status.
Change log should be after '---'
Also, when looking into this, I realized that we already have pmbus_regulator_get_error_flags() which has somewhat overlapping functionality. Would it be possible to utilize that function to get the error status instead of more or less hand-coding it ?
Thanks,
Guenter
Hi Guenter,
Quoted 13 lines · Guenter Roeck
Quoted 4 lines · Naresh Solanki
From: Patrick Rudolph <[email protected]>
Add
get_statusforpmbus_regulator_ops.Quoted 8 lines
Changes:
- use lock throughout the function
- Avoid line continuation upto 100 column
- Optimize use of & and | operator
- Check for VOUT, IOUT, TEMPERATURE bit in status word before checking respective status register for fault.
- Report regulator current status.
Quoted 1 line
Change log should be after '---'
Sure
Quoted 5 lines
Also, when looking into this, I realized that we already have
pmbus_regulator_get_error_flags()which has somewhat overlapping functionality. Would it be possible to utilize that function to get the error status instead of more or less hand-coding it ?
Sure. But looking at get_status scope, I feel that we are already checking the following:
1. Check if regulator is off & yes then return off
2. If not off then it should be on & has power good then return on
3. If no power good then this itself is error condition so return error. Decoding status register for fault just double confirms that & may not be needed in get_status unless we are going to print or utilize the error bit information in some other way but that is out of scope of get_status call unless I missed something.
Does this approach makes sense ?
Quoted 3 lines
Thanks,