Skip to contentSkip to conversation

hwmon: (mlxreg-fan) Extend number of supporetd fans

PATCH Applied Vadim Pasternak 2 participants 2 messages Aug 24, 2023 – Aug 25, 2023 Hardware monitoring

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 hwmon: (mlxreg-fan) Extend number of supporetd fans

Some new big modular systems can be equipped with up to 24 fans. Extend maximum number of fans accordingly.

---
 drivers/hwmon/mlxreg-fan.c | 12 +++++++++++-
 1 file changed, 11 insertions(+), 1 deletion(-)
drivers/hwmon/mlxreg-fan.c +11 -1
index c2a96468c9b4..a5f89aab3fb4 100644
@@ -12,7 +12,7 @@
 #include <linux/regmap.h>
 #include <linux/thermal.h>
 
-#define MLXREG_FAN_MAX_TACHO		14
+#define MLXREG_FAN_MAX_TACHO		24
 #define MLXREG_FAN_MAX_PWM		4
 #define MLXREG_FAN_PWM_NOT_CONNECTED	0xff
 #define MLXREG_FAN_MAX_STATE		10
@@ -300,6 +300,16 @@ static const struct hwmon_channel_info * const mlxreg_fan_hwmon_info[] = {
 			   HWMON_F_INPUT | HWMON_F_FAULT,
 			   HWMON_F_INPUT | HWMON_F_FAULT,
 			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
+			   HWMON_F_INPUT | HWMON_F_FAULT,
 			   HWMON_F_INPUT | HWMON_F_FAULT),
 	HWMON_CHANNEL_INFO(pwm,
 			   HWMON_PWM_INPUT,
Signature · 1 line