perf list: fix short description for some cache events
PATCH 1/1 perf list: fix short description for some cache events
Correct the short description of the following events:DCW_REQ, DCW_REQ_CHIP_HIT, DCW_REQ_DRAWER_HIT, DCW_REQ_IV, DCW_ON_CHIP, DCW_ON_CHIP_IV, DCW_ON_CHIP_CHIP_HIT, DCW_ON_CHIP_DRAWER_HIT, CW_ON_MODULE, DCW_ON_DRAWER, DCW_OFF_DRAWER, IDCW_ON_MODULE_IV, IDCW_ON_MODULE_CHIP_HIT, IDCW_ON_MODULE_DRAWER_HIT, IDCW_ON_DRAWER_IV, IDCW_ON_DRAWER_CHIP_HIT, IDCW_ON_DRAWER_DRAWER_HIT, IDCW_OFF_DRAWER_IV, IDCW_OFF_DRAWER_CHIP_HIT, IDCW_OFF_DRAWER_DRAWER_HIT, ICW_REQ, ICW_REQ_IV, CW_REQ_CHIP_HIT, ICW_REQ_DRAWER_HIT, ICW_ON_CHIP, ICW_ON_CHIP_IV, ICW_ON_CHIP_CHIP_HIT, ICW_ON_CHIP_DRAWER_HIT, ICW_ON_MODULE and ICW_OFF_DRAWER.
The second Cache should be L2-Cache.
Output before (display diff of the first four events)
# perf list -d
DCW_REQ
[Directory Write Level 1 Data Cache from Cache. Unit: cpum_cf]
DCW_REQ_CHIP_HIT
[Directory Write Level 1 Data Cache from Cache with Chip HP \
Hit. Unit: cpum_cf]
DCW_REQ_DRAWER_HIT
[Directory Write Level 1 Data Cache from Cache with Drawer \
HP Hit. Unit: cpum_cf]
DCW_REQ_IV
[Directory Write Level 1 Data Cache from Cache with Intervention. \
Unit: cpum_cf]Output after:
# perf list -d
DCW_REQ
[Directory Write Level 1 Data Cache from L2-Cache. Unit: cpum_cf]
DCW_REQ_CHIP_HIT
[Directory Write Level 1 Data Cache from L2-Cache with Chip HP \
Hit. Unit: cpum_cf]
DCW_REQ_DRAWER_HIT
[Directory Write Level 1 Data Cache from L2-Cache with Drawer \
HP Hit. Unit: cpum_cf]
DCW_REQ_IV
[Directory Write Level 1 Data Cache from L2-Cache with \
Intervention. Unit: cpum_cf]--- .../pmu-events/arch/s390/cf_z16/extended.json | 62 +++++++++---------- 1 file changed, 31 insertions(+), 31 deletions(-)
tools/perf/pmu-events/arch/s390/cf_z16/extended.json +31 -31
@@ -94,77 +94,77 @@ "Unit": "CPU-M-CF", "EventCode": "145", "EventName": "DCW_REQ", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "146", "EventName": "DCW_REQ_IV", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "147", "EventName": "DCW_REQ_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "148", "EventName": "DCW_REQ_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "149", "EventName": "DCW_ON_CHIP", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "150", "EventName": "DCW_ON_CHIP_IV", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "151", "EventName": "DCW_ON_CHIP_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache after using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "152", "EventName": "DCW_ON_CHIP_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "153", "EventName": "DCW_ON_MODULE", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Module Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Module L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Module Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "154", "EventName": "DCW_ON_DRAWER", - "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "155", "EventName": "DCW_OFF_DRAWER", - "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache." }, {
@@ -199,140 +199,140 @@ "Unit": "CPU-M-CF", "EventCode": "160", "EventName": "IDCW_ON_MODULE_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "161", "EventName": "IDCW_ON_MODULE_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using chip horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "162", "EventName": "IDCW_ON_MODULE_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "163", "EventName": "IDCW_ON_DRAWER_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "164", "EventName": "IDCW_ON_DRAWER_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "165", "EventName": "IDCW_ON_DRAWER_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "166", "EventName": "IDCW_OFF_DRAWER_IV", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "167", "EventName": "IDCW_OFF_DRAWER_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Chip Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Chip Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "168", "EventName": "IDCW_OFF_DRAWER_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Drawer Hit", + "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Drawer Hit", "PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "169", "EventName": "ICW_REQ", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced the requestors Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "170", "EventName": "ICW_REQ_IV", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "171", "EventName": "ICW_REQ_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "172", "EventName": "ICW_REQ_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "173", "EventName": "ICW_ON_CHIP", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "174", "EventName": "ICW_ON_CHIP_IV", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Intervention", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Intervention", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Chip Level-2 cache with intervention." }, { "Unit": "CPU-M-CF", "EventCode": "175", "EventName": "ICW_ON_CHIP_CHIP_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Chip HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Chip HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using chip level horizontal persistence, Chip-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "176", "EventName": "ICW_ON_CHIP_DRAWER_HIT", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Drawer HP Hit", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Drawer HP Hit", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip level 2 cache using drawer level horizontal persistence, Drawer-HP hit." }, { "Unit": "CPU-M-CF", "EventCode": "177", "EventName": "ICW_ON_MODULE", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "178", "EventName": "ICW_ON_DRAWER", - "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Drawer Level-2 cache." }, { "Unit": "CPU-M-CF", "EventCode": "179", "EventName": "ICW_OFF_DRAWER", - "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer Cache", + "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer L2-Cache", "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an Off-Drawer Level-2 cache." }, {
Signature · 1 line
2.43.0
Quoted 42 lines · Thomas Richter
Correct the short description of the following events:
DCW_REQ,DCW_REQ_CHIP_HIT,DCW_REQ_DRAWER_HIT,DCW_REQ_IV,DCW_ON_CHIP,DCW_ON_CHIP_IV,DCW_ON_CHIP_CHIP_HIT,DCW_ON_CHIP_DRAWER_HIT,CW_ON_MODULE,DCW_ON_DRAWER,DCW_OFF_DRAWER,IDCW_ON_MODULE_IV,IDCW_ON_MODULE_CHIP_HIT,IDCW_ON_MODULE_DRAWER_HIT,IDCW_ON_DRAWER_IV,IDCW_ON_DRAWER_CHIP_HIT,IDCW_ON_DRAWER_DRAWER_HIT,IDCW_OFF_DRAWER_IV,IDCW_OFF_DRAWER_CHIP_HIT,IDCW_OFF_DRAWER_DRAWER_HIT,ICW_REQ,ICW_REQ_IV,CW_REQ_CHIP_HIT,ICW_REQ_DRAWER_HIT,ICW_ON_CHIP,ICW_ON_CHIP_IV,ICW_ON_CHIP_CHIP_HIT,ICW_ON_CHIP_DRAWER_HIT,ICW_ON_MODULEandICW_OFF_DRAWER.The second Cache should be L2-Cache.
Output before (display diff of the first four events)
# perf list -d DCW_REQ [Directory Write Level 1 Data Cache from Cache. Unit: cpum_cf] DCW_REQ_CHIP_HIT [Directory Write Level 1 Data Cache from Cache with Chip HP \ Hit. Unit: cpum_cf] DCW_REQ_DRAWER_HIT [Directory Write Level 1 Data Cache from Cache with Drawer \ HP Hit. Unit: cpum_cf] DCW_REQ_IV [Directory Write Level 1 Data Cache from Cache with Intervention. \ Unit: cpum_cf]Output after:
# perf list -d DCW_REQ [Directory Write Level 1 Data Cache from L2-Cache. Unit: cpum_cf] DCW_REQ_CHIP_HIT [Directory Write Level 1 Data Cache from L2-Cache with Chip HP \ Hit. Unit: cpum_cf] DCW_REQ_DRAWER_HIT [Directory Write Level 1 Data Cache from L2-Cache with Drawer \ HP Hit. Unit: cpum_cf] DCW_REQ_IV [Directory Write Level 1 Data Cache from L2-Cache with \ Intervention. Unit: cpum_cf]
Quoted 4 lines
Fixes 7f76b3113068 ("perf list: Add IBM z16 event description for s390")Reported-by Andreas Krebbel <[email protected]>Signed-off-by Thomas Richter <[email protected]>Acked-by Andreas Krebbel <[email protected]>
Thanks,
Ian
Quoted 11 lines · Thomas Richter
Correct the short description of the following events:
DCW_REQ,DCW_REQ_CHIP_HIT,DCW_REQ_DRAWER_HIT,DCW_REQ_IV,DCW_ON_CHIP,DCW_ON_CHIP_IV,DCW_ON_CHIP_CHIP_HIT,DCW_ON_CHIP_DRAWER_HIT,CW_ON_MODULE,DCW_ON_DRAWER,DCW_OFF_DRAWER,IDCW_ON_MODULE_IV,IDCW_ON_MODULE_CHIP_HIT,IDCW_ON_MODULE_DRAWER_HIT,IDCW_ON_DRAWER_IV,IDCW_ON_DRAWER_CHIP_HIT,IDCW_ON_DRAWER_DRAWER_HIT,IDCW_OFF_DRAWER_IV,IDCW_OFF_DRAWER_CHIP_HIT,IDCW_OFF_DRAWER_DRAWER_HIT,ICW_REQ,ICW_REQ_IV,CW_REQ_CHIP_HIT,ICW_REQ_DRAWER_HIT,ICW_ON_CHIP,ICW_ON_CHIP_IV,ICW_ON_CHIP_CHIP_HIT,ICW_ON_CHIP_DRAWER_HIT,ICW_ON_MODULEandICW_OFF_DRAWER.
Quoted 1 line
[...]
Applied to perf-tools-next, thanks!
Best regards,
Signature · 1 line
Namhyung Kim <[email protected]>