Skip to contentSkip to conversation

platform/x86:dell-laptop: Add knobs to change battery charge settings

PATCH Superseded Andres Salomon 5 participants 13 messages Aug 15, 2024 – Aug 24, 2024

Subsystems (4)

v3 of 4 Superseded Latest is v4 →

lore
Share & tools
lore
#1 lore raw

PATCH v2 2/2 platform/x86:dell-laptop: remove duplicate code w/ battery function

In reply to Andres Salomon

The dell battery patch added dell_send_request_for_tokenid() and dell_set_std_token_value(), which encapsulates a very common pattern when SMBIOS queries are addressed to token->location. This calls them in various places outside of the dell laptop code, allowing us to delete a bunch of code.

Also some very minor cleanups:
- mark the kbd init functions as __init
- don't read buffer.output unless dell_send_request() was successful.
- actually return errors from micmute_led_set/mute_led_set instead of always returning 0.

Only minor behavior changes; the delayed read of buffer.output and actually returning errors for the brightness_set_blocking hooks.

---
Changes in v2:
- use renamed and helper functions dell_send_request_for_tokenid() and dell_set_std_token_value().
- no longer need to move functions around
- document the brightness_set_blocking hook changes

---
 drivers/platform/x86/dell/dell-laptop.c | 105 ++++++------------------
 1 file changed, 25 insertions(+), 80 deletions(-)
drivers/platform/x86/dell/dell-laptop.c +25 -80
index 8cc05f0fab91..5df0944e5bf6 100644
@@ -935,43 +935,24 @@ static void dell_cleanup_rfkill(void)
 static int dell_send_intensity(struct backlight_device *bd)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
-	int ret;
-
-	token = dell_smbios_find_token(BRIGHTNESS_TOKEN);
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer,
-			   token->location, bd->props.brightness, 0, 0);
-	if (power_supply_is_system_supplied() > 0)
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_WRITE, SELECT_TOKEN_AC);
-	else
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_WRITE, SELECT_TOKEN_BAT);
+	u16 pwr;
 
-	return ret;
+	pwr = power_supply_is_system_supplied() > 0 ?
+			SELECT_TOKEN_AC : SELECT_TOKEN_BAT;
+	return dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_WRITE,
+			pwr, BRIGHTNESS_TOKEN, bd->props.brightness);
 }
 
 static int dell_get_intensity(struct backlight_device *bd)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
 	int ret;
+	u16 pwr;
 
-	token = dell_smbios_find_token(BRIGHTNESS_TOKEN);
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer, token->location, 0, 0, 0);
-	if (power_supply_is_system_supplied() > 0)
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_READ, SELECT_TOKEN_AC);
-	else
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_READ, SELECT_TOKEN_BAT);
-
+	pwr = power_supply_is_system_supplied() > 0 ?
+			SELECT_TOKEN_AC : SELECT_TOKEN_BAT;
+	ret = dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_READ, pwr,
+			BRIGHTNESS_TOKEN, 0);
 	if (ret == 0)
 		ret = buffer.output[1];
 
@@ -1395,20 +1376,11 @@ static int kbd_set_state_safe(struct kbd_state *state, struct kbd_state *old)
 static int kbd_set_token_bit(u8 bit)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
-	int ret;
 
 	if (bit >= ARRAY_SIZE(kbd_tokens))
 		return -EINVAL;
 
-	token = dell_smbios_find_token(kbd_tokens[bit]);
-	if (!token)
-		return -EINVAL;
-
-	dell_fill_request(&buffer, token->location, token->value, 0, 0);
-	ret = dell_send_request(&buffer, CLASS_TOKEN_WRITE, SELECT_TOKEN_STD);
-
-	return ret;
+	return dell_set_std_token_value(&buffer, kbd_tokens[bit], USE_TVAL);
 }
 
 static int kbd_get_token_bit(u8 bit)
@@ -1427,11 +1399,10 @@ static int kbd_get_token_bit(u8 bit)
 
 	dell_fill_request(&buffer, token->location, 0, 0, 0);
 	ret = dell_send_request(&buffer, CLASS_TOKEN_READ, SELECT_TOKEN_STD);
-	val = buffer.output[1];
-
 	if (ret)
 		return ret;
 
+	val = buffer.output[1];
 	return (val == token->value);
 }
 
@@ -1537,7 +1508,7 @@ static inline int kbd_init_info(void)
 
 }
 
-static inline void kbd_init_tokens(void)
+static inline void __init kbd_init_tokens(void)
 {
 	int i;
 
@@ -1546,7 +1517,7 @@ static inline void kbd_init_tokens(void)
 			kbd_token_bits |= BIT(i);
 }
 
-static void kbd_init(void)
+static void __init kbd_init(void)
 {
 	int ret;
 
@@ -2171,21 +2142,11 @@ static int micmute_led_set(struct led_classdev *led_cdev,
 			   enum led_brightness brightness)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
 	int state = brightness != LED_OFF;
+	u32 val;
 
-	if (state == 0)
-		token = dell_smbios_find_token(GLOBAL_MIC_MUTE_DISABLE);
-	else
-		token = dell_smbios_find_token(GLOBAL_MIC_MUTE_ENABLE);
-
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer, token->location, token->value, 0, 0);
-	dell_send_request(&buffer, CLASS_TOKEN_WRITE, SELECT_TOKEN_STD);
-
-	return 0;
+	val = state == 0 ? GLOBAL_MIC_MUTE_DISABLE : GLOBAL_MIC_MUTE_ENABLE;
+	return dell_set_std_token_value(&buffer, val, USE_TVAL);
 }
 
 static struct led_classdev micmute_led_cdev = {
@@ -2199,21 +2160,11 @@ static int mute_led_set(struct led_classdev *led_cdev,
 			   enum led_brightness brightness)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
 	int state = brightness != LED_OFF;
+	u32 val;
 
-	if (state == 0)
-		token = dell_smbios_find_token(GLOBAL_MUTE_DISABLE);
-	else
-		token = dell_smbios_find_token(GLOBAL_MUTE_ENABLE);
-
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer, token->location, token->value, 0, 0);
-	dell_send_request(&buffer, CLASS_TOKEN_WRITE, SELECT_TOKEN_STD);
-
-	return 0;
+	val = state == 0 ? GLOBAL_MUTE_DISABLE : GLOBAL_MUTE_ENABLE;
+	return dell_set_std_token_value(&buffer, val, USE_TVAL);
 }
 
 static struct led_classdev mute_led_cdev = {
@@ -2498,7 +2449,7 @@ static void __exit dell_battery_exit(void)
 
 static int __init dell_init(void)
 {
-	struct calling_interface_token *token;
+	struct calling_interface_buffer buffer;
 	int max_intensity = 0;
 	int ret;
 
@@ -2560,16 +2511,10 @@ static int __init dell_init(void)
 	if (acpi_video_get_backlight_type() != acpi_backlight_vendor)
 		return 0;
 
-	token = dell_smbios_find_token(BRIGHTNESS_TOKEN);
-	if (token) {
-		struct calling_interface_buffer buffer;
-
-		dell_fill_request(&buffer, token->location, 0, 0, 0);
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_READ, SELECT_TOKEN_AC);
-		if (ret == 0)
-			max_intensity = buffer.output[3];
-	}
+	ret = dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_READ,
+			SELECT_TOKEN_AC, BRIGHTNESS_TOKEN, 0);
+	if (ret == 0)
+		max_intensity = buffer.output[3];
 
 	if (max_intensity) {
 		struct backlight_properties props;
Signature · 8 lines
2.39.2




-- 
I'm available for contract & employment work, please contact me if
interested.
#0 lore raw

PATCH v3 1/2 platform/x86:dell-laptop: Add knobs to change battery charge settings

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +33 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +316 -0

363 lines not on this page · raw message

drivers/platform/x86/dell/dell-smbios.h +7 -0
index ea0cc38642a2..77baa15eb523 100644
@@ -33,6 +33,13 @@
 #define KBD_LED_AUTO_50_TOKEN	0x02EB
 #define KBD_LED_AUTO_75_TOKEN	0x02EC
 #define KBD_LED_AUTO_100_TOKEN	0x02F6
+#define BAT_PRI_AC_MODE_TOKEN	0x0341
+#define BAT_ADAPTIVE_MODE_TOKEN	0x0342
+#define BAT_CUSTOM_MODE_TOKEN	0x0343
+#define BAT_STANDARD_MODE_TOKEN	0x0346
+#define BAT_EXPRESS_MODE_TOKEN	0x0347
+#define BAT_CUSTOM_CHARGE_START	0x0349
+#define BAT_CUSTOM_CHARGE_END	0x034A
 #define GLOBAL_MIC_MUTE_ENABLE	0x0364
 #define GLOBAL_MIC_MUTE_DISABLE	0x0365
 #define GLOBAL_MUTE_ENABLE	0x058C
Signature · 7 lines
2.39.2



-- 
I'm available for contract & employment work, please contact me if
interested.
#3 lore raw
kernel test robot noticed the following build warnings:

Hi Andres,

kernel test robot noticed the following build warnings:

[auto build test WARNING on sre-power-supply/for-next]
[also build test WARNING on linus/master v6.11-rc3 next-20240816] [cannot apply to amd-pstate/linux-next amd-pstate/bleeding-edge] [If your patch is applied to the wrong git tree, kindly drop us a note. And when submitting patch, we suggest to use '--base' as documented in
https://git-scm.com/docs/git-format-patch#_base_tree_information]

url:    https://github.com/intel-lab-lkp/linux/commits/Andres-Salomon/platform-x86-dell-laptop-remove-duplicate-code-w-battery-function/20240816-102156
base:   https://git.kernel.org/pub/scm/linux/kernel/git/sre/linux-power-supply.git for-next
patch link:    https://lore.kernel.org/r/20240815192848.3489d3e1%405400
patch subject: [PATCH v3 1/2] platform/x86:dell-laptop: Add knobs to change  battery charge settings
reproduce: (https://download.01.org/0day-ci/archive/20240816/[email protected]/reproduce)

If you fix the issue in a separate patch/commit (i.e. not just a new version of the same patch/commit), kindly add following tags
| Reported-by: kernel test robot <[email protected]>
| Closes: https://lore.kernel.org/oe-kbuild-all/[email protected]/

All warnings (new ones prefixed by >>):

Warning: Documentation/devicetree/bindings/regulator/siliconmitus,sm5703-regulator.yaml references a file that doesn't exist: Documentation/devicetree/bindings/mfd/siliconmitus,sm5703.yaml
Warning: Documentation/hwmon/g762.rst references a file that doesn't exist: Documentation/devicetree/bindings/hwmon/g762.txt
Warning: MAINTAINERS references a file that doesn't exist: Documentation/devicetree/bindings/reserved-memory/qcom
Warning: MAINTAINERS references a file that doesn't exist: Documentation/devicetree/bindings/display/exynos/
Warning: MAINTAINERS references a file that doesn't exist: Documentation/devicetree/bindings/misc/fsl,qoriq-mc.txt

>> Warning: /sys/class/power_supply/<supply_name>/charge_type is defined 2 times:  ./Documentation/ABI/testing/sysfs-class-power-dell:0  ./Documentation/ABI/testing/sysfs-class-power:375

Using alabaster theme

Signature · 2 lines
0-DAY CI Kernel Test Service
https://github.com/intel/lkp-tests/wiki
maintainer
#4 lore raw
In reply to Andres Salomon
Quoted 120 lines · Andres Salomon

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +33 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 107

Quoted 7 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {

Please don't try to do this in one go but split it into two (define and then declaration of the variable).

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 112

Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+	{ BAT_STANDARD_MODE_TOKEN, "Standard" },
+	{ BAT_EXPRESS_MODE_TOKEN, "Fast" },
+	{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
+	{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
+	{ BAT_CUSTOM_MODE_TOKEN, "Custom" },

I suggest aligning the strings with tabs for better readability.

Quoted 92 lines
drivers/platform/x86/dell/dell-laptop.c +78 -0
+};
+static u32 battery_supported_modes;
+
 module_param(force_rfkill, bool, 0444);
 MODULE_PARM_DESC(force_rfkill, "enable rfkill on non whitelisted models");
 
@@ -353,6 +367,32 @@ static const struct dmi_system_id dell_quirks[] __initconst = {
 	{ }
 };
 
+/* -1 is a sentinel value, telling us to use token->value */
+#define USE_TVAL ((u32) -1)
+static int dell_send_request_for_tokenid(struct calling_interface_buffer *buffer,
+					 u16 class, u16 select, u16 tokenid,
+					 u32 val)
+{
+	struct calling_interface_token *token;
+
+	token = dell_smbios_find_token(tokenid);
+	if (!token)
+		return -ENODEV;
+
+	if (val == USE_TVAL)
+		val = token->value;
+
+	dell_fill_request(buffer, token->location, val, 0, 0);
+	return dell_send_request(buffer, class, select);
+}
+
+static inline int dell_set_std_token_value(struct calling_interface_buffer *buffer,
+		u16 tokenid, u32 value)
+{
+	return dell_send_request_for_tokenid(buffer, CLASS_TOKEN_WRITE,
+			SELECT_TOKEN_STD, tokenid, value);
+}
+
 /*
  * Derived from information in smbios-wireless-ctl:
  *
@@ -2183,6 +2223,279 @@ static struct led_classdev mute_led_cdev = {
 	.default_trigger = "audio-mute",
 };
 
+static int dell_battery_set_mode(const u16 tokenid)
+{
+	struct calling_interface_buffer buffer;
+
+	return dell_set_std_token_value(&buffer, tokenid, USE_TVAL);
+}
+
+static int dell_battery_read(const u16 tokenid)
+{
+	struct calling_interface_buffer buffer;
+	int err;
+
+	err = dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_READ,
+			SELECT_TOKEN_STD, tokenid, 0);
+	if (err)
+		return err;
+
+	if (buffer.output[1] > INT_MAX)
+		return -EIO;
+
+	return buffer.output[1];
+}
+
+static bool dell_battery_mode_is_active(const u16 tokenid)
+{
+	struct calling_interface_token *token;
+	int ret;
+
+	ret = dell_battery_read(tokenid);
+	if (ret < 0)
+		return false;
+
+	token = dell_smbios_find_token(tokenid);
+	/* token's already verified by dell_battery_read() */
+
+	return token->value == (u16) ret;
+}
+
+/*
+ * The rules: the minimum start charging value is 50%. The maximum
+ * start charging value is 95%. The minimum end charging value is
+ * 55%. The maximum end charging value is 100%. And finally, there
+ * has to be at least a 5% difference between start & end values.
+ */
+#define CHARGE_START_MIN	50
+#define CHARGE_START_MAX	95
+#define CHARGE_END_MIN		55
+#define CHARGE_END_MAX		100
+#define CHARGE_MIN_DIFF		5

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2284

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+
+static int dell_battery_set_custom_charge_start(int start)
+{
+	struct calling_interface_buffer buffer;
+	int end;
+
+	if (start < CHARGE_START_MIN)
+		start = CHARGE_START_MIN;
+	else if (start > CHARGE_START_MAX)
+		start = CHARGE_START_MAX;

We have clamp().

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2289

Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+
+	end = dell_battery_read(BAT_CUSTOM_CHARGE_END);
+	if (end < 0)
+		return end;
+	if ((end - start) < CHARGE_MIN_DIFF)

Extra parenthesis.

Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+		start = end - CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_START,
+			start);
+}

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2304

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+
+static int dell_battery_set_custom_charge_end(int end)
+{
+	struct calling_interface_buffer buffer;
+	int start;
+
+	if (end < CHARGE_END_MIN)
+		end = CHARGE_END_MIN;
+	else if (end > CHARGE_END_MAX)
+		end = CHARGE_END_MAX;

clamp.

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2309

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+	start = dell_battery_read(BAT_CUSTOM_CHARGE_START);
+	if (start < 0)
+		return start;
+	if ((end - start) < CHARGE_MIN_DIFF)

Extra parenthesis.

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +6 -0
+		end = start + CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_END, end);
+}
+
+static ssize_t charge_type_show(struct device *dev,

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2325

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+		struct device_attribute *attr,
+		char *buf)
+{
+	ssize_t count = 0;
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		bool active;
+
+		if (!(battery_supported_modes & BIT(i)))

Why not store this supported information into battery_modes itself? What's the benefit of obfuscation it with the extra variable & BIT()?

Signature · 1 line
 i.
Quoted 219 lines
drivers/platform/x86/dell/dell-laptop.c +176 -0
+			continue;
+
+		active = dell_battery_mode_is_active(battery_modes[i].token);
+		count += sysfs_emit_at(buf, count, active ? "[%s] " : "%s ",
+				battery_modes[i].label);
+	}
+
+	/* convert the last space to a newline */
+	if (count > 0)
+		count--;
+	count += sysfs_emit_at(buf, count, "\n");
+
+	return count;
+}
+
+static ssize_t charge_type_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	bool matched = false;
+	int err, i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		if (!(battery_supported_modes & BIT(i)))
+			continue;
+
+		if (sysfs_streq(battery_modes[i].label, buf)) {
+			matched = true;
+			break;
+		}
+	}
+	if (!matched || !(battery_supported_modes & BIT(i)))
+		return -EINVAL;
+
+	err = dell_battery_set_mode(battery_modes[i].token);
+	if (err)
+		return err;
+
+	return size;
+}
+
+static ssize_t charge_control_start_threshold_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	int start;
+
+	start = dell_battery_read(BAT_CUSTOM_CHARGE_START);
+	if (start < 0)
+		return start;
+
+	if (start > CHARGE_START_MAX)
+		return -EIO;
+
+	return sysfs_emit(buf, "%d\n", start);
+}
+
+static ssize_t charge_control_start_threshold_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	int ret, start;
+
+	ret = kstrtoint(buf, 10, &start);
+	if (ret)
+		return ret;
+	if (start < 0 || start > 100)
+		return -EINVAL;
+
+	ret = dell_battery_set_custom_charge_start(start);
+	if (ret)
+		return ret;
+
+	return size;
+}
+
+static ssize_t charge_control_end_threshold_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	int end;
+
+	end = dell_battery_read(BAT_CUSTOM_CHARGE_END);
+	if (end < 0)
+		return end;
+
+	if (end > CHARGE_END_MAX)
+		return -EIO;
+
+	return sysfs_emit(buf, "%d\n", end);
+}
+
+static ssize_t charge_control_end_threshold_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	int ret, end;
+
+	ret = kstrtouint(buf, 10, &end);
+	if (ret)
+		return ret;
+	if (end < 0 || end > 100)
+		return -EINVAL;
+
+	ret = dell_battery_set_custom_charge_end(end);
+	if (ret)
+		return ret;
+
+	return size;
+}
+
+static DEVICE_ATTR_RW(charge_control_start_threshold);
+static DEVICE_ATTR_RW(charge_control_end_threshold);
+static DEVICE_ATTR_RW(charge_type);
+
+static struct attribute *dell_battery_attrs[] = {
+	&dev_attr_charge_control_start_threshold.attr,
+	&dev_attr_charge_control_end_threshold.attr,
+	&dev_attr_charge_type.attr,
+	NULL,
+};
+ATTRIBUTE_GROUPS(dell_battery);
+
+static int dell_battery_add(struct power_supply *battery,
+		struct acpi_battery_hook *hook)
+{
+	/* this currently only supports the primary battery */
+	if (strcmp(battery->desc->name, "BAT0") != 0)
+		return -ENODEV;
+
+	return device_add_groups(&battery->dev, dell_battery_groups);
+}
+
+static int dell_battery_remove(struct power_supply *battery,
+		struct acpi_battery_hook *hook)
+{
+	device_remove_groups(&battery->dev, dell_battery_groups);
+	return 0;
+}
+
+static struct acpi_battery_hook dell_battery_hook = {
+	.add_battery = dell_battery_add,
+	.remove_battery = dell_battery_remove,
+	.name = "Dell Primary Battery Extension",
+};
+
+static u32 __init battery_get_supported_modes(void)
+{
+	u32 modes = 0;
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		if (dell_smbios_find_token(battery_modes[i].token))
+			modes |= BIT(i);
+	}
+
+	return modes;
+}
+
+static void __init dell_battery_init(struct device *dev)
+{
+	battery_supported_modes = battery_get_supported_modes();
+
+	if (battery_supported_modes != 0)
+		battery_hook_register(&dell_battery_hook);
+}
+
+static void __exit dell_battery_exit(void)
+{
+	if (battery_supported_modes != 0)
+		battery_hook_unregister(&dell_battery_hook);
+}
+
 static int __init dell_init(void)
 {
 	struct calling_interface_token *token;
@@ -2219,6 +2532,7 @@ static int __init dell_init(void)
 		touchpad_led_init(&platform_device->dev);
 
 	kbd_led_init(&platform_device->dev);
+	dell_battery_init(&platform_device->dev);
 
 	dell_laptop_dir = debugfs_create_dir("dell_laptop", NULL);
 	debugfs_create_file("rfkill", 0444, dell_laptop_dir, NULL,
@@ -2293,6 +2607,7 @@ static int __init dell_init(void)
 	if (mute_led_registered)
 		led_classdev_unregister(&mute_led_cdev);
 fail_led:
+	dell_battery_exit();
 	dell_cleanup_rfkill();
 fail_rfkill:
 	platform_device_del(platform_device);
@@ -2311,6 +2626,7 @@ static void __exit dell_exit(void)
 	if (quirks && quirks->touchpad_led)
 		touchpad_led_exit();
 	kbd_led_exit();
+	dell_battery_exit();
 	backlight_device_unregister(dell_backlight_device);
 	if (micmute_led_registered)
 		led_classdev_unregister(&micmute_led_cdev);
drivers/platform/x86/dell/dell-smbios.h +7 -0
index ea0cc38642a2..77baa15eb523 100644
@@ -33,6 +33,13 @@
 #define KBD_LED_AUTO_50_TOKEN	0x02EB
 #define KBD_LED_AUTO_75_TOKEN	0x02EC
 #define KBD_LED_AUTO_100_TOKEN	0x02F6
+#define BAT_PRI_AC_MODE_TOKEN	0x0341
+#define BAT_ADAPTIVE_MODE_TOKEN	0x0342
+#define BAT_CUSTOM_MODE_TOKEN	0x0343
+#define BAT_STANDARD_MODE_TOKEN	0x0346
+#define BAT_EXPRESS_MODE_TOKEN	0x0347
+#define BAT_CUSTOM_CHARGE_START	0x0349
+#define BAT_CUSTOM_CHARGE_END	0x034A
 #define GLOBAL_MIC_MUTE_ENABLE	0x0364
 #define GLOBAL_MIC_MUTE_DISABLE	0x0365
 #define GLOBAL_MUTE_ENABLE	0x058C
maintainer
#5 lore raw
Quoted 125 lines · On Friday 16 August 2024 16:56:24 Ilpo Järvinen wrote:
Quoted 123 lines · Andres Salomon

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +33 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 
Quoted 7 lines

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 107

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {

Please don't try to do this in one go but split it into two (define and then declaration of the variable).

Why? Splitting definition of this anonymous structure and definition of variable would leak definition of anonymous structure of out the scope where it is used.

Quoted 7 lines

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 112

Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+	{ BAT_STANDARD_MODE_TOKEN, "Standard" },
+	{ BAT_EXPRESS_MODE_TOKEN, "Fast" },
+	{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
+	{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
+	{ BAT_CUSTOM_MODE_TOKEN, "Custom" },

I suggest aligning the strings with tabs for better readability.

For aligning something for better readability in "git diff" and "git show" (which includes also git format-patch and emails) is better to use spaces and not tabs. tab-alignment in git makes worse readability (due to name of the token).

Quoted 105 lines
Quoted 92 lines
drivers/platform/x86/dell/dell-laptop.c +78 -0
+};
+static u32 battery_supported_modes;
+
 module_param(force_rfkill, bool, 0444);
 MODULE_PARM_DESC(force_rfkill, "enable rfkill on non whitelisted models");
 
@@ -353,6 +367,32 @@ static const struct dmi_system_id dell_quirks[] __initconst = {
 	{ }
 };
 
+/* -1 is a sentinel value, telling us to use token->value */
+#define USE_TVAL ((u32) -1)
+static int dell_send_request_for_tokenid(struct calling_interface_buffer *buffer,
+					 u16 class, u16 select, u16 tokenid,
+					 u32 val)
+{
+	struct calling_interface_token *token;
+
+	token = dell_smbios_find_token(tokenid);
+	if (!token)
+		return -ENODEV;
+
+	if (val == USE_TVAL)
+		val = token->value;
+
+	dell_fill_request(buffer, token->location, val, 0, 0);
+	return dell_send_request(buffer, class, select);
+}
+
+static inline int dell_set_std_token_value(struct calling_interface_buffer *buffer,
+		u16 tokenid, u32 value)
+{
+	return dell_send_request_for_tokenid(buffer, CLASS_TOKEN_WRITE,
+			SELECT_TOKEN_STD, tokenid, value);
+}
+
 /*
  * Derived from information in smbios-wireless-ctl:
  *
@@ -2183,6 +2223,279 @@ static struct led_classdev mute_led_cdev = {
 	.default_trigger = "audio-mute",
 };
 
+static int dell_battery_set_mode(const u16 tokenid)
+{
+	struct calling_interface_buffer buffer;
+
+	return dell_set_std_token_value(&buffer, tokenid, USE_TVAL);
+}
+
+static int dell_battery_read(const u16 tokenid)
+{
+	struct calling_interface_buffer buffer;
+	int err;
+
+	err = dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_READ,
+			SELECT_TOKEN_STD, tokenid, 0);
+	if (err)
+		return err;
+
+	if (buffer.output[1] > INT_MAX)
+		return -EIO;
+
+	return buffer.output[1];
+}
+
+static bool dell_battery_mode_is_active(const u16 tokenid)
+{
+	struct calling_interface_token *token;
+	int ret;
+
+	ret = dell_battery_read(tokenid);
+	if (ret < 0)
+		return false;
+
+	token = dell_smbios_find_token(tokenid);
+	/* token's already verified by dell_battery_read() */
+
+	return token->value == (u16) ret;
+}
+
+/*
+ * The rules: the minimum start charging value is 50%. The maximum
+ * start charging value is 95%. The minimum end charging value is
+ * 55%. The maximum end charging value is 100%. And finally, there
+ * has to be at least a 5% difference between start & end values.
+ */
+#define CHARGE_START_MIN	50
+#define CHARGE_START_MAX	95
+#define CHARGE_END_MIN		55
+#define CHARGE_END_MAX		100
+#define CHARGE_MIN_DIFF		5

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2284

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+
+static int dell_battery_set_custom_charge_start(int start)
+{
+	struct calling_interface_buffer buffer;
+	int end;
+
+	if (start < CHARGE_START_MIN)
+		start = CHARGE_START_MIN;
+	else if (start > CHARGE_START_MAX)
+		start = CHARGE_START_MAX;

We have clamp().

Quoted 7 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2289

Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+
+	end = dell_battery_read(BAT_CUSTOM_CHARGE_END);
+	if (end < 0)
+		return end;
+	if ((end - start) < CHARGE_MIN_DIFF)

Extra parenthesis.

I pointed about this in previous version and from the discussion the conclusion was that there is no reason to remove extra parenthesis.

Quoted 35 lines
Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+		start = end - CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_START,
+			start);
+}

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2304

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+
+static int dell_battery_set_custom_charge_end(int end)
+{
+	struct calling_interface_buffer buffer;
+	int start;
+
+	if (end < CHARGE_END_MIN)
+		end = CHARGE_END_MIN;
+	else if (end > CHARGE_END_MAX)
+		end = CHARGE_END_MAX;

clamp.

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2309

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+	start = dell_battery_read(BAT_CUSTOM_CHARGE_START);
+	if (start < 0)
+		return start;
+	if ((end - start) < CHARGE_MIN_DIFF)

Extra parenthesis.

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+		end = start + CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_END, end);
+}
+
+static ssize_t charge_type_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	ssize_t count = 0;
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2325

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +6 -0
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		bool active;
+
+		if (!(battery_supported_modes & BIT(i)))

Why not store this supported information into battery_modes itself?

Same style is already used in other parts in this driver / source file.

Quoted 1 line

What's the benefit of obfuscation it with the extra variable & BIT()?

In my opinion, this is not obfuscation but clear and common style how to check which values of some enumeration are supported.

Storing this kind of information into battery_modes is not possible because battery_modes is constant array with constant data.

Quoted 223 lines
Signature · 2 lines
-- 
 i.
Quoted 219 lines
drivers/platform/x86/dell/dell-laptop.c +176 -0
+			continue;
+
+		active = dell_battery_mode_is_active(battery_modes[i].token);
+		count += sysfs_emit_at(buf, count, active ? "[%s] " : "%s ",
+				battery_modes[i].label);
+	}
+
+	/* convert the last space to a newline */
+	if (count > 0)
+		count--;
+	count += sysfs_emit_at(buf, count, "\n");
+
+	return count;
+}
+
+static ssize_t charge_type_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	bool matched = false;
+	int err, i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		if (!(battery_supported_modes & BIT(i)))
+			continue;
+
+		if (sysfs_streq(battery_modes[i].label, buf)) {
+			matched = true;
+			break;
+		}
+	}
+	if (!matched || !(battery_supported_modes & BIT(i)))
+		return -EINVAL;
+
+	err = dell_battery_set_mode(battery_modes[i].token);
+	if (err)
+		return err;
+
+	return size;
+}
+
+static ssize_t charge_control_start_threshold_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	int start;
+
+	start = dell_battery_read(BAT_CUSTOM_CHARGE_START);
+	if (start < 0)
+		return start;
+
+	if (start > CHARGE_START_MAX)
+		return -EIO;
+
+	return sysfs_emit(buf, "%d\n", start);
+}
+
+static ssize_t charge_control_start_threshold_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	int ret, start;
+
+	ret = kstrtoint(buf, 10, &start);
+	if (ret)
+		return ret;
+	if (start < 0 || start > 100)
+		return -EINVAL;
+
+	ret = dell_battery_set_custom_charge_start(start);
+	if (ret)
+		return ret;
+
+	return size;
+}
+
+static ssize_t charge_control_end_threshold_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	int end;
+
+	end = dell_battery_read(BAT_CUSTOM_CHARGE_END);
+	if (end < 0)
+		return end;
+
+	if (end > CHARGE_END_MAX)
+		return -EIO;
+
+	return sysfs_emit(buf, "%d\n", end);
+}
+
+static ssize_t charge_control_end_threshold_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	int ret, end;
+
+	ret = kstrtouint(buf, 10, &end);
+	if (ret)
+		return ret;
+	if (end < 0 || end > 100)
+		return -EINVAL;
+
+	ret = dell_battery_set_custom_charge_end(end);
+	if (ret)
+		return ret;
+
+	return size;
+}
+
+static DEVICE_ATTR_RW(charge_control_start_threshold);
+static DEVICE_ATTR_RW(charge_control_end_threshold);
+static DEVICE_ATTR_RW(charge_type);
+
+static struct attribute *dell_battery_attrs[] = {
+	&dev_attr_charge_control_start_threshold.attr,
+	&dev_attr_charge_control_end_threshold.attr,
+	&dev_attr_charge_type.attr,
+	NULL,
+};
+ATTRIBUTE_GROUPS(dell_battery);
+
+static int dell_battery_add(struct power_supply *battery,
+		struct acpi_battery_hook *hook)
+{
+	/* this currently only supports the primary battery */
+	if (strcmp(battery->desc->name, "BAT0") != 0)
+		return -ENODEV;
+
+	return device_add_groups(&battery->dev, dell_battery_groups);
+}
+
+static int dell_battery_remove(struct power_supply *battery,
+		struct acpi_battery_hook *hook)
+{
+	device_remove_groups(&battery->dev, dell_battery_groups);
+	return 0;
+}
+
+static struct acpi_battery_hook dell_battery_hook = {
+	.add_battery = dell_battery_add,
+	.remove_battery = dell_battery_remove,
+	.name = "Dell Primary Battery Extension",
+};
+
+static u32 __init battery_get_supported_modes(void)
+{
+	u32 modes = 0;
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		if (dell_smbios_find_token(battery_modes[i].token))
+			modes |= BIT(i);
+	}
+
+	return modes;
+}
+
+static void __init dell_battery_init(struct device *dev)
+{
+	battery_supported_modes = battery_get_supported_modes();
+
+	if (battery_supported_modes != 0)
+		battery_hook_register(&dell_battery_hook);
+}
+
+static void __exit dell_battery_exit(void)
+{
+	if (battery_supported_modes != 0)
+		battery_hook_unregister(&dell_battery_hook);
+}
+
 static int __init dell_init(void)
 {
 	struct calling_interface_token *token;
@@ -2219,6 +2532,7 @@ static int __init dell_init(void)
 		touchpad_led_init(&platform_device->dev);
 
 	kbd_led_init(&platform_device->dev);
+	dell_battery_init(&platform_device->dev);
 
 	dell_laptop_dir = debugfs_create_dir("dell_laptop", NULL);
 	debugfs_create_file("rfkill", 0444, dell_laptop_dir, NULL,
@@ -2293,6 +2607,7 @@ static int __init dell_init(void)
 	if (mute_led_registered)
 		led_classdev_unregister(&mute_led_cdev);
 fail_led:
+	dell_battery_exit();
 	dell_cleanup_rfkill();
 fail_rfkill:
 	platform_device_del(platform_device);
@@ -2311,6 +2626,7 @@ static void __exit dell_exit(void)
 	if (quirks && quirks->touchpad_led)
 		touchpad_led_exit();
 	kbd_led_exit();
+	dell_battery_exit();
 	backlight_device_unregister(dell_backlight_device);
 	if (micmute_led_registered)
 		led_classdev_unregister(&micmute_led_cdev);
drivers/platform/x86/dell/dell-smbios.h +7 -0
index ea0cc38642a2..77baa15eb523 100644
@@ -33,6 +33,13 @@
 #define KBD_LED_AUTO_50_TOKEN	0x02EB
 #define KBD_LED_AUTO_75_TOKEN	0x02EC
 #define KBD_LED_AUTO_100_TOKEN	0x02F6
+#define BAT_PRI_AC_MODE_TOKEN	0x0341
+#define BAT_ADAPTIVE_MODE_TOKEN	0x0342
+#define BAT_CUSTOM_MODE_TOKEN	0x0343
+#define BAT_STANDARD_MODE_TOKEN	0x0346
+#define BAT_EXPRESS_MODE_TOKEN	0x0347
+#define BAT_CUSTOM_CHARGE_START	0x0349
+#define BAT_CUSTOM_CHARGE_END	0x034A
 #define GLOBAL_MIC_MUTE_ENABLE	0x0364
 #define GLOBAL_MIC_MUTE_DISABLE	0x0365
 #define GLOBAL_MUTE_ENABLE	0x058C
maintainer
#8 lore raw
In reply to Andres Salomon

Hello Andres,

I have just comments for this change. It looks good. After resolving them you can add my tag: Reviewed-by: Pali Rohár <[email protected]>

Quoted 18 lines · On Thursday 15 August 2024 19:28:48 Andres Salomon wrote:

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

Quoted 2 lines

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:

I think that the information below is not needed to have in commit message. We also do not include links or information about previous version of patch sent by you.

Quoted 4 lines

https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

...

Quoted 8 lines
drivers/platform/x86/dell/dell-laptop.c +8 -0
+static ssize_t charge_type_store(struct device *dev,
+		struct device_attribute *attr,
+		const char *buf, size_t size)
+{
+	bool matched = false;
+	int err, i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2358

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+		if (!(battery_supported_modes & BIT(i)))
+			continue;
+
+		if (sysfs_streq(battery_modes[i].label, buf)) {
+			matched = true;
+			break;
+		}
+	}
+	if (!matched || !(battery_supported_modes & BIT(i)))
+		return -EINVAL;

Check for "!(battery_supported_modes & BIT(i))" is redundant here. "matched" can be true only in case if the i-th mode is supported and was specified in buffer.

Quoted 7 lines
drivers/platform/x86/dell/dell-laptop.c +7 -0
+
+	err = dell_battery_set_mode(battery_modes[i].token);
+	if (err)
+		return err;
+
+	return size;
+}
maintainer
#2 lore raw

Re: [PATCH v2 2/2] platform/x86:dell-laptop: remove duplicate code w/ battery function

In reply to Andres Salomon

Hello, this change looks good, I have just minor comments about improving names of variables.

Quoted 17 lines · On Thursday 15 August 2024 19:35:46 Andres Salomon wrote:
drivers/platform/x86/dell/dell-laptop.c +0 -9
index 8cc05f0fab91..5df0944e5bf6 100644
@@ -935,43 +935,24 @@ static void dell_cleanup_rfkill(void)
 static int dell_send_intensity(struct backlight_device *bd)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
-	int ret;
-
-	token = dell_smbios_find_token(BRIGHTNESS_TOKEN);
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer,
-			   token->location, bd->props.brightness, 0, 0);

drivers/platform/x86/dell/dell-laptop.c static void dell_cleanup_rfkill(void) · line 940

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +2 -7
-	if (power_supply_is_system_supplied() > 0)
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_WRITE, SELECT_TOKEN_AC);
-	else
-		ret = dell_send_request(&buffer,
-					CLASS_TOKEN_WRITE, SELECT_TOKEN_BAT);
+	u16 pwr;
 
-	return ret;
+	pwr = power_supply_is_system_supplied() > 0 ?

I would suggest to call this variable "select" or something like that. Name "pwr" is too generic and does not express the fact that is stores token select id.

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +3 -0
+			SELECT_TOKEN_AC : SELECT_TOKEN_BAT;
+	return dell_send_request_for_tokenid(&buffer, CLASS_TOKEN_WRITE,
+			pwr, BRIGHTNESS_TOKEN, bd->props.brightness);
 }

...

Quoted 11 lines
drivers/platform/x86/dell/dell-laptop.c +1 -4
@@ -2171,21 +2142,11 @@ static int micmute_led_set(struct led_classdev *led_cdev,
 			   enum led_brightness brightness)
 {
 	struct calling_interface_buffer buffer;
-	struct calling_interface_token *token;
 	int state = brightness != LED_OFF;
+	u32 val;
 
-	if (state == 0)
-		token = dell_smbios_find_token(GLOBAL_MIC_MUTE_DISABLE);
-	else

drivers/platform/x86/dell/dell-laptop.c static int micmute_led_set(struct led_classdev *led_cdev, · line 2148

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +1 -9
-		token = dell_smbios_find_token(GLOBAL_MIC_MUTE_ENABLE);
-
-	if (!token)
-		return -ENODEV;
-
-	dell_fill_request(&buffer, token->location, token->value, 0, 0);
-	dell_send_request(&buffer, CLASS_TOKEN_WRITE, SELECT_TOKEN_STD);
-
-	return 0;
+	val = state == 0 ? GLOBAL_MIC_MUTE_DISABLE : GLOBAL_MIC_MUTE_ENABLE;

Here variable "val" is also too generic. The real meaning of this variable is tokenid. So I would suggest to use this name as it is used in other places in this file for storing token id.

Quoted 2 lines
drivers/platform/x86/dell/dell-laptop.c +1 -0
+	return dell_set_std_token_value(&buffer, val, USE_TVAL);
 }
#6 lore raw
In reply to Pali Rohár
Quoted 134 lines · On Fri, 16 Aug 2024 18:33:41 +0200 Pali Rohár <[email protected]> wrote:
Quoted 125 lines · On Friday 16 August 2024 16:56:24 Ilpo Järvinen wrote:
Quoted 123 lines · Andres Salomon

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +33 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 
Quoted 7 lines

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 107

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {  

Please don't try to do this in one go but split it into two (define and then declaration of the variable).

Quoted 3 lines

Why? Splitting definition of this anonymous structure and definition of variable would leak definition of anonymous structure of out the scope where it is used.

Also, it's two different arrays that we then have to keep synced as we add new modes. That's the main reason I went for the combined struct.

Quoted 9 lines
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 112

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+	{ BAT_STANDARD_MODE_TOKEN, "Standard" },
+	{ BAT_EXPRESS_MODE_TOKEN, "Fast" },
+	{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
+	{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
+	{ BAT_CUSTOM_MODE_TOKEN, "Custom" },  

I suggest aligning the strings with tabs for better readability.

Quoted 5 lines

For aligning something for better readability in "git diff" and "git show" (which includes also git format-patch and emails) is better to use spaces and not tabs. tab-alignment in git makes worse readability (due to name of the token).

Okay, so I'm hearing to align them, but to use spaces? I'll line everything up with where "Standard" and "Adaptive" are.

[...]

Quoted 16 lines
Quoted 16 lines
Quoted 16 lines
drivers/platform/x86/dell/dell-laptop.c +16 -0
+
+/*
+ * The rules: the minimum start charging value is 50%. The maximum
+ * start charging value is 95%. The minimum end charging value is
+ * 55%. The maximum end charging value is 100%. And finally, there
+ * has to be at least a 5% difference between start & end values.
+ */
+#define CHARGE_START_MIN	50
+#define CHARGE_START_MAX	95
+#define CHARGE_END_MIN		55
+#define CHARGE_END_MAX		100
+#define CHARGE_MIN_DIFF		5
+
+static int dell_battery_set_custom_charge_start(int start)
+{
+	struct calling_interface_buffer buffer;
Quoted 8 lines
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2284

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +6 -0
+	int end;
+
+	if (start < CHARGE_START_MIN)
+		start = CHARGE_START_MIN;
+	else if (start > CHARGE_START_MAX)
+		start = CHARGE_START_MAX;  

We have clamp().

Thanks, I'll use that.

Quoted 9 lines
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2289

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+
+	end = dell_battery_read(BAT_CUSTOM_CHARGE_END);
+	if (end < 0)
+		return end;
+	if ((end - start) < CHARGE_MIN_DIFF)  

Extra parenthesis.

Quoted 21 lines

I pointed about this in previous version and from the discussion the conclusion was that there is no reason to remove extra parenthesis.

Quoted 18 lines
Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+		start = end - CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_START,
+			start);
+}

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2304

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+
+static int dell_battery_set_custom_charge_end(int end)
+{
+	struct calling_interface_buffer buffer;
+	int start;
+
+	if (end < CHARGE_END_MIN)
+		end = CHARGE_END_MIN;
+	else if (end > CHARGE_END_MAX)
+		end = CHARGE_END_MAX;  

clamp.

+1

Quoted 28 lines
Quoted 17 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2309

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+	start = dell_battery_read(BAT_CUSTOM_CHARGE_START);
+	if (start < 0)
+		return start;
+	if ((end - start) < CHARGE_MIN_DIFF)  

Extra parenthesis.

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+		end = start + CHARGE_MIN_DIFF;
+
+	return dell_set_std_token_value(&buffer, BAT_CUSTOM_CHARGE_END, end);
+}
+
+static ssize_t charge_type_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	ssize_t count = 0;
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2325

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +6 -0
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		bool active;
+
+		if (!(battery_supported_modes & BIT(i)))  

Why not store this supported information into battery_modes itself?

Same style is already used in other parts in this driver / source file.

Quoted 8 lines
Quoted 1 line

What's the benefit of obfuscation it with the extra variable & BIT()?

In my opinion, this is not obfuscation but clear and common style how to check which values of some enumeration are supported.

Storing this kind of information into battery_modes is not possible because battery_modes is constant array with constant data.

Yep. It's not a given that all modes will be supported by the BIOS.

Signature · 2 lines
I'm available for contract & employment work, please contact me if
interested.
#9 lore raw
In reply to Andres Salomon
kernel test robot noticed the following build warnings:

Hi Andres,

kernel test robot noticed the following build warnings:

[auto build test WARNING on sre-power-supply/for-next]
[also build test WARNING on linus/master v6.11-rc3 next-20240816] [cannot apply to amd-pstate/linux-next amd-pstate/bleeding-edge] [If your patch is applied to the wrong git tree, kindly drop us a note. And when submitting patch, we suggest to use '--base' as documented in
https://git-scm.com/docs/git-format-patch#_base_tree_information]

url:    https://github.com/intel-lab-lkp/linux/commits/Andres-Salomon/platform-x86-dell-laptop-remove-duplicate-code-w-battery-function/20240816-102156
base:   https://git.kernel.org/pub/scm/linux/kernel/git/sre/linux-power-supply.git for-next
patch link:    https://lore.kernel.org/r/20240815192848.3489d3e1%405400
patch subject: [PATCH v3 1/2] platform/x86:dell-laptop: Add knobs to change  battery charge settings
config: x86_64-randconfig-122-20240817 (https://download.01.org/0day-ci/archive/20240818/[email protected]/config)
compiler: gcc-12 (Debian 12.2.0-14) 12.2.0
reproduce (this is a W=1 build): (https://download.01.org/0day-ci/archive/20240818/[email protected]/reproduce)

If you fix the issue in a separate patch/commit (i.e. not just a new version of the same patch/commit), kindly add following tags
| Reported-by: kernel test robot <[email protected]>
| Closes: https://lore.kernel.org/oe-kbuild-all/[email protected]/

All warnings (new ones prefixed by >>, old ones prefixed by <<):

WARNING: modpost: missing MODULE_DESCRIPTION() in arch/x86/mm/testmmiotrace.o
WARNING: modpost: missing MODULE_DESCRIPTION() in kernel/locking/test-ww_mutex.o
WARNING: modpost: missing MODULE_DESCRIPTION() in mm/kasan/kasan_test.o

>> WARNING: modpost: drivers/platform/x86/dell/dell-laptop: section mismatch in reference: dell_init+0x637 (section: .init.text) -> dell_battery_exit (section: .exit.text)

WARNING: modpost: missing MODULE_DESCRIPTION() in drivers/devfreq/governor_userspace.o

Signature · 2 lines
0-DAY CI Kernel Test Service
https://github.com/intel/lkp-tests/wiki
maintainer
#7 lore raw
In reply to Pali Rohár
Quoted 134 lines · Pali Rohár
Quoted 125 lines · On Friday 16 August 2024 16:56:24 Ilpo Järvinen wrote:
Quoted 123 lines · Andres Salomon

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +33 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 
Quoted 7 lines

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 107

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {

Please don't try to do this in one go but split it into two (define and then declaration of the variable).

Quoted 3 lines

Why? Splitting definition of this anonymous structure and definition of variable would leak definition of anonymous structure of out the scope where it is used.

As is, this splits "static const" from battery_modes. Naming anonymous struct isn't as bad problem as you seem to suggest (and named structs are also easier when grepping).

Quoted 14 lines
Quoted 5 lines
Quoted 5 lines
drivers/platform/x86/dell/dell-laptop.c +5 -0
+static ssize_t charge_type_show(struct device *dev,
+		struct device_attribute *attr,
+		char *buf)
+{
+	ssize_t count = 0;
Quoted 8 lines

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2325

Quoted 6 lines
drivers/platform/x86/dell/dell-laptop.c +6 -0
+	int i;
+
+	for (i = 0; i < ARRAY_SIZE(battery_modes); i++) {
+		bool active;
+
+		if (!(battery_supported_modes & BIT(i)))

Why not store this supported information into battery_modes itself?

Quoted 1 line

Same style is already used in other parts in this driver / source file.

If you refer to 'triggers', it is definitely not an example of something that is easy to follow. With triggers, it seems that there's undocumented array-index to hw-field bit mapping going on (or to be more precise, the documentation for the hw field is in a far-away documentation block so it's practically impossible to make the connection when reading the struct).

Quoted 7 lines
Quoted 1 line

What's the benefit of obfuscation it with the extra variable & BIT()?

In my opinion, this is not obfuscation but clear and common style how to check which values of some enumeration are supported.

Storing this kind of information into battery_modes is not possible because battery_modes is constant array with constant data.

Err, it's proposed to be const by this patch. Why that struct cannot be changed to be non-const? Clearly there is battery mode related data that is not const.

As a sidenote now that I had to look, this driver is doing other BIT(n) obfusction too (and open-coded FIELD_PREP() seem to be plenty as well).

--
i.

#10 lore raw
In reply to Andres Salomon

Hi,

Quoted 18 lines · Andres Salomon

The Dell BIOS allows you to set custom charging modes, which is useful in particular for extending battery life. This adds support for tweaking those various settings from Linux via sysfs knobs. One might, for example, have their laptop plugged into power at their desk the vast majority of the time and choose fairly aggressive battery-saving settings (eg, only charging once the battery drops below 50% and only charging up to 80%). When leaving for a trip, it would be more useful to instead switch to a standard charging mode (top off at 100%, charge any time power is available). Rebooting into the BIOS to change the charging mode settings is a hassle.

For the Custom charging type mode, we reuse the common charge_control_{start,end}_threshold sysfs power_supply entries. The BIOS also has a bunch of other charging modes (with varying levels of usefulness), so this also adds a 'charge_type' sysfs entry that maps the standard values to Dell-specific ones and documents those mappings in sysfs-class-power-dell.

Quoted 8 lines

This work is based on a patch by Perry Yuan <[email protected]> and Limonciello Mario <[email protected]> submitted back in 2020:
https://lore.kernel.org/all/[email protected]/
Both of their email addresses bounce, so I'm assuming they're no longer with the company. I've reworked most of the patch to make it smaller and cleaner.

Thank you for your patch, some small comments below. For the next version please also address Pali's and Ilpo's remarks.

Quoted 53 lines

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +23 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.

Documentation/ABI/testing/sysfs-class-power-dell line 33

Quoted 10 lines
Documentation/ABI/testing/sysfs-class-power-dell new file +10 -0
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+

As the kernel test robot reports:

Warning: /sys/class/power_supply/<supply_name>/charge_type is defined 2 times: ./Documentation/ABI/testing/sysfs-class-power-dell:0 ./Documentation/ABI/testing/sysfs-class-power:375

So please drop this. What you could do is instead submit (as a separate) patch an update to Documentation/ABI/testing/sysfs-class-power:375 to use your IMHO more readable version.

And when doing so I think it would best to replace "The Dell BIOS calls this ..." with "In vendor tooling this may also be called ...".

Quoted 34 lines
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 113

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {
+	{ BAT_STANDARD_MODE_TOKEN, "Standard" },
+	{ BAT_EXPRESS_MODE_TOKEN, "Fast" },
+	{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
+	{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
+	{ BAT_CUSTOM_MODE_TOKEN, "Custom" },
+};

So Ilpo suggested to split this (first declare the struct type and then declare an array of that type) and Pali suggested to keep this as is.

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 114

Quoted 1 line
drivers/platform/x86/dell/dell-laptop.c +1 -0
+static u32 battery_supported_modes;

I see there also is some disagreement on keeping battery_modes[] const vs adding a flag for this in the struct.

IMHO in both cases either option is fine, so you (Andres) get to choose which solution you prefer in either case.

I do see there is some confusion about Ilpo's split suggestion, to clarify that, what I believe is Ilpo meant doing something like this:

struct battery_mode_info {
	int token;
	const char *label;
};

static const struct battery_mode_info battery_modes[] = {
{ BAT_STANDARD_MODE_TOKEN, "Standard" }, { BAT_EXPRESS_MODE_TOKEN, "Fast" },
{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
{ BAT_CUSTOM_MODE_TOKEN, "Custom" },
};

Also whatever option you chose please align the second column using spaces as done above.

<snip>

Quoted 4 lines
drivers/platform/x86/dell/dell-laptop.c +4 -0
+static void __init dell_battery_init(struct device *dev)
+{
+	battery_supported_modes = battery_get_supported_modes();
+

drivers/platform/x86/dell/dell-laptop.c static struct led_classdev mute_led_cdev = { · line 2498

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+	if (battery_supported_modes != 0)
+		battery_hook_register(&dell_battery_hook);
+}
+
+static void __exit dell_battery_exit(void)
+{
+	if (battery_supported_modes != 0)
+		battery_hook_unregister(&dell_battery_hook);
+}
+

You cannot mark this __exit and also call it from the __init dell_init() function to cleanup on errors, this lead to the following error reported by the kernel test robot:

WARNING: modpost: drivers/platform/x86/dell/dell-laptop: section mismatch in reference: dell_init+0x637 (section: .init.text) -> dell_battery_exit (section: .exit.text)

to fix this please drop the __exit marking from this function.

Regards,

Hans

#11 lore raw
Quoted 3 lines · On Mon, 19 Aug 2024 15:59:45 +0200 Hans de Goede <[email protected]> wrote:

Hi,

On 8/16/24 1:28 AM, Andres Salomon wrote:

[...]

Quoted 67 lines
Quoted 54 lines

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +23 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.

Documentation/ABI/testing/sysfs-class-power-dell line 33

Quoted 10 lines
Documentation/ABI/testing/sysfs-class-power-dell new file +10 -0
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+  

As the kernel test robot reports:

Quoted 10 lines

Warning: /sys/class/power_supply/<supply_name>/charge_type is defined 2 times: ./Documentation/ABI/testing/sysfs-class-power-dell:0 ./Documentation/ABI/testing/sysfs-class-power:375

So please drop this. What you could do is instead submit (as a separate) patch an update to Documentation/ABI/testing/sysfs-class-power:375 to use your IMHO more readable version.

And when doing so I think it would best to replace "The Dell BIOS calls this ..." with "In vendor tooling this may also be called ...".

Is this what you had in mind? I don't see many users of charge_type, and I'm not sure whether the assumptions I'm making there are correct.

https://lore.kernel.org/lkml/20240820041942.30ed42f3@5400/

Quoted 53 lines
Quoted 34 lines
drivers/platform/x86/dell/Kconfig +1 -0
index 85a78ef91182..02405793163c 100644
@@ -49,6 +49,7 @@ config DELL_LAPTOP
 	default m
 	depends on DMI
 	depends on BACKLIGHT_CLASS_DEVICE
+	depends on ACPI_BATTERY
 	depends on ACPI_VIDEO || ACPI_VIDEO = n
 	depends on RFKILL || RFKILL = n
 	depends on DELL_WMI || DELL_WMI = n
drivers/platform/x86/dell/dell-laptop.c +2 -0
index 6552dfe491c6..8cc05f0fab91 100644
@@ -22,11 +22,13 @@
 #include <linux/io.h>
 #include <linux/rfkill.h>
 #include <linux/power_supply.h>
+#include <linux/sysfs.h>
 #include <linux/acpi.h>
 #include <linux/mm.h>
 #include <linux/i8042.h>
 #include <linux/debugfs.h>
 #include <linux/seq_file.h>
+#include <acpi/battery.h>
 #include <acpi/video.h>
 #include "dell-rbtn.h"
 #include "dell-smbios.h"
@@ -99,6 +101,18 @@ static bool force_rfkill;
 static bool micmute_led_registered;
 static bool mute_led_registered;
 

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 113

Quoted 10 lines
drivers/platform/x86/dell/dell-laptop.c +10 -0
+static const struct {
+	int token;
+	const char *label;
+} battery_modes[] = {
+	{ BAT_STANDARD_MODE_TOKEN, "Standard" },
+	{ BAT_EXPRESS_MODE_TOKEN, "Fast" },
+	{ BAT_PRI_AC_MODE_TOKEN, "Trickle" },
+	{ BAT_ADAPTIVE_MODE_TOKEN, "Adaptive" },
+	{ BAT_CUSTOM_MODE_TOKEN, "Custom" },
+};  

So Ilpo suggested to split this (first declare the struct type and then declare an array of that type) and Pali suggested to keep this as is.

drivers/platform/x86/dell/dell-laptop.c static bool force_rfkill; · line 114

Quoted 1 line
drivers/platform/x86/dell/dell-laptop.c +1 -0
+static u32 battery_supported_modes;  

I see there also is some disagreement on keeping battery_modes[] const vs adding a flag for this in the struct.

Quoted 6 lines

IMHO in both cases either option is fine, so you (Andres) get to choose which solution you prefer in either case.

I do see there is some confusion about Ilpo's split suggestion, to clarify that, what I believe is Ilpo meant doing something like this:

Thanks for clarify that, my fault for misreading what they'd written!

Signature · 2 lines
I'm available for contract & employment work, please contact me if
interested.
#12 lore raw

Hi,

Quoted 85 lines · Andres Salomon
Quoted 3 lines · On Mon, 19 Aug 2024 15:59:45 +0200 Hans de Goede <[email protected]> wrote:

Hi,

On 8/16/24 1:28 AM, Andres Salomon wrote:

[...]

Quoted 67 lines
Quoted 54 lines

---
Changes in v3:
- switch tokenid and class types
- be stricter with results from both userspace and BIOS
- no longer allow failed BIOS reads
- rename/move dell_send_request_by_token_loc, and add helper function
- only allow registration for BAT0
- rename charge_type modes to match power_supply names
Changes in v2, based on extensive feedback from Pali Rohár <[email protected]>:
- code style changes
- change battery write API to use token->value instead of passed value
- stop caching current mode, instead querying SMBIOS as needed
- drop the separate list of charging modes enum
- rework the list of charging mode strings
- query SMBIOS for supported charging modes
- split dell_battery_custom_set() up

---
 .../ABI/testing/sysfs-class-power-dell        |  33 ++
 drivers/platform/x86/dell/Kconfig             |   1 +
 drivers/platform/x86/dell/dell-laptop.c       | 316 ++++++++++++++++++
 drivers/platform/x86/dell/dell-smbios.h       |   7 +
 4 files changed, 357 insertions(+)
 create mode 100644 Documentation/ABI/testing/sysfs-class-power-dell
Documentation/ABI/testing/sysfs-class-power-dell new file +23 -0
new file mode 100644
index 000000000000..d8c542177558
@@ -0,0 +1,33 @@
+What:		/sys/class/power_supply/<supply_name>/charge_type
+Date:		August 2024
+KernelVersion:	6.12
+Contact:	[email protected]
+Description:
+		Select the charging algorithm to use for the (primary)
+		battery.
+
+		Standard:
+			Fully charge the battery at a moderate rate.
+		Fast:
+			Quickly charge the battery using fast-charge
+			technology. This is harder on the battery than
+			standard charging and may lower its lifespan.
+			The Dell BIOS calls this ExpressCharge™.
+		Trickle:
+			Users who primarily operate the system while
+			plugged into an external power source can extend
+			battery life with this mode. The Dell BIOS calls
+			this "Primarily AC Use".
+		Adaptive:
+			Automatically optimize battery charge rate based
+			on typical usage pattern.

Documentation/ABI/testing/sysfs-class-power-dell line 33

Quoted 10 lines
Documentation/ABI/testing/sysfs-class-power-dell new file +10 -0
+		Custom:
+			Use the charge_control_* properties to determine
+			when to start and stop charging. Advanced users
+			can use this to drastically extend battery life.
+
+		Access: Read, Write
+		Valid values:
+			      "Standard", "Fast", "Trickle",
+			      "Adaptive", "Custom"
+  

As the kernel test robot reports:

Quoted 10 lines

Warning: /sys/class/power_supply/<supply_name>/charge_type is defined 2 times: ./Documentation/ABI/testing/sysfs-class-power-dell:0 ./Documentation/ABI/testing/sysfs-class-power:375

So please drop this. What you could do is instead submit (as a separate) patch an update to Documentation/ABI/testing/sysfs-class-power:375 to use your IMHO more readable version.

And when doing so I think it would best to replace "The Dell BIOS calls this ..." with "In vendor tooling this may also be called ...".

Quoted 4 lines

Is this what you had in mind? I don't see many users of charge_type, and I'm not sure whether the assumptions I'm making there are correct.

https://lore.kernel.org/lkml/20240820041942.30ed42f3@5400/

Yes that is what I head in mind, thank you for doing this.

I'll try to review that patch soon-ish.

I'll review and likely merge your new v4 "Add knobs" patch on Monday.

Regards,

Hans