Skip to contentSkip to conversation

vxlan: Support of Hub Spoke Network to use the same VNI

RFC PATCH In review Ted Chen 2 participants 13 messages Feb 1, 2025 – Feb 5, 2025

Subsystems (2)
lore
Share & tools
lore

Ted Chen

author
#0 lore raw

cover vxlan: Support of Hub Spoke Network to use the same VNI

This RFC series proposes an implementation to enable the configuration of vxlan devices in a Hub-Spoke Network, allowing multiple vxlan devices to share the same VNI while being associated with different remote IPs under the same UDP port.

== Use case ==
In a Hub-Spoke Network, there is a central VTEP acting as the gateway, along with multiple outer VTEPs. Each outer VTEP communicates exclusively with the central VTEP and has no direct connection to other outer VTEPs. As a result, data exchanged between outer VTEPs must traverse the central VTEP. This design enhances security and enables centralized auditing and monitoring at the central VTEP.

== Existing methods ==
Currently, there are three methods to implement the use case.

Method 1:
The central VTEP establishes a separate vxlan tunnel with each outer VTEP, creating a vxlan device with a different VNI for each tunnel. All vxlan devices are then added to the same Linux bridge to enable forwarding.

Drawbacks: Complex configuration.
Each tenant requires multiple VNIs.

Method 2:
The central VTEP creates a single vxlan device using the same VNI, without configuring a remote IP. The IP addresses of all outer VTEPs are stored in the fdb. To enable forwarding, the vxlan device is added to a Linux bridge with hairpin mode enabled.

Drawbacks: unnecessary overhead or network anomalies
The hairpin mode may broadcast packets to all outer VTEPs, causing the source outer VTEP receiving packets it originally sent to the central VTEP. If the packet from the source outer VTEP is a broadcast packet, the broadcasting back of the packet can cause network anomalies.

Method 3:
The central VTEP uses the same VNI but different UDP ports to create a vxlan device for each outer VTEP, each tunneling to its corresponding outer VTEP. All the vxlan devices in the central VTEP are then added to the same Linux bridge to enable forwarding.

Drawbacks: complex configuration and potential security issues. Multiple UDP ports are required.

== Proposed implementation ==
In the central VTEP, each tenant only requires a single VNI, and all tenants share the same UDP port. This can avoid the drawbacks of the above three methods.

As in below example,
- a tunnel is established between vxlan42.1 in the central VTEP and vxlan42 in the outer VTEP1:
ip link add vxlan42.1 type vxlan id 42 \

          local 10.0.0.3 remote 10.0.0.1 dstport 4789

- a tunnel is established between vxlan42.2 in the central VTEP and vxlan42 in the outer VTEP2:
ip link add vxlan42.2 type vxlan id 42 \
local 10.0.0.3 remote 10.0.0.2 dstport 4789

    ┌────────────────────────────────────────────┐
    │       ┌─────────────────────────┐  central │
    │       │          br0            │    VTEP  │
    │       └─┬────────────────────┬──┘          │
    │   ┌─────┴───────┐      ┌─────┴───────┐     │          
    │   │ vxlan42.1   │      │  vxlan42.2  │     │
    │   └─────────────┘      └─────────────┘     │  
    └───────────────────┬─┬──────────────────────┘
                        │ │ eth0 10.0.0.3:4789
                        │ │            
                        │ │            
       ┌────────────────┘ └───────────────┐
       │eth0 10.0.0.1:4789                │eth0 10.0.0.2:4789
 ┌─────┴───────┐                    ┌─────┴───────┐
 │outer VTEP1  │                    │outer VTEP2  │
 │     vxlan42 │                    │     vxlan42 │
 └─────────────┘                    └─────────────┘

== Test scenario ==
ip netns add ns_1
ip link add veth1 type veth peer name veth1-peer ip link set veth1 netns ns_1
ip netns exec ns_1 ip addr add 10.0.1.1/24 dev veth1 ip netns exec ns_1 ip link set veth1 up
ip netns exec ns_1 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_1 ip addr add 192.168.0.1/24 dev vxlan42 ip netns exec ns_1 ip link set up dev vxlan42

ip netns add ns_2
ip link add veth2 type veth peer name veth2-peer ip link set veth2 netns ns_2
ip netns exec ns_2 ip addr add 10.0.1.2/24 dev veth2 ip netns exec ns_2 ip link set veth2 up
ip netns exec ns_2 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_2 ip addr add 192.168.0.2/24 dev vxlan42 ip netns exec ns_2 ip link set up dev vxlan42

ip netns add ns_c
ip link add veth3 type veth peer name veth3-peer ip link set veth3 netns ns_c
ip netns exec ns_c ip addr add 10.0.1.3/24 dev veth3 ip netns exec ns_c ip link set veth3 up
ip netns exec ns_c ip link add vxlan42.1 type vxlan id 42 \

                   local 10.0.1.3 remote 10.0.1.1 dstport 4789
ip netns exec ns_c ip link add vxlan42.2 type vxlan id 42 \
                   local 10.0.1.3 remote 10.0.1.2 dstport 4789

ip netns exec ns_c ip link set up dev vxlan42.1 ip netns exec ns_c ip link set up dev vxlan42.2 ip netns exec ns_c ip link add name br0 type bridge ip netns exec ns_c ip link set br0 up
ip netns exec ns_c ip link set vxlan42.1 master br0 ip netns exec ns_c ip link set vxlan42.2 master br0

ip link add name br1 type bridge
ip link set br1 up
ip link set veth1-peer up
ip link set veth2-peer up
ip link set veth3-peer up
ip link set veth1-peer master br1
ip link set veth2-peer master br1
ip link set veth3-peer master br1

ip netns exec ns_1 ping 192.168.0.2 -I 192.168.0.1

Ted Chen (3):
vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and
remote_ip
vxlan: Do not treat vxlan dev as used when unicast remote_ip
mismatches
vxlan: vxlan_rcv(): Update comment to inlucde ipv6

 drivers/net/vxlan/vxlan_core.c | 38 +++++++++++++++++++++++++++-------
 1 file changed, 31 insertions(+), 7 deletions(-)
Signature · 1 line
2.39.2
author
#1 lore raw

RFC PATCH 1/3 vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and remote_ip

vxlan_vs_find_vni() currently searches the vni hash table in a vs and returns a vxlan_dev associated with the specified "vni". While this works when the remote_ips are stored in the vxlan fdb, it fails to handle the case where the remote_ip is just configured in the vxlan device outside of the vxlan fdb, because multiple vxlan devices with different remote_ip may share a single vni when the remote_ip is configured in the vxlan device (i.e., not stored in the vxlan fdb). In that case, further check of remote_ip to identify vxlan_dev more precisely.

---
 drivers/net/vxlan/vxlan_core.c | 32 ++++++++++++++++++++++++++------
 1 file changed, 26 insertions(+), 6 deletions(-)
drivers/net/vxlan/vxlan_core.c +26 -6
index 05c10acb2a57..3ca74a97c44f 100644
@@ -94,8 +94,10 @@ static struct vxlan_sock *vxlan_find_sock(struct net *net, sa_family_t family,
 
 static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 					   int ifindex, __be32 vni,
+					   const struct sk_buff *skb,
 					   struct vxlan_vni_node **vninode)
 {
+	union vxlan_addr saddr;
 	struct vxlan_vni_node *vnode;
 	struct vxlan_dev_node *node;
 
@@ -116,14 +118,31 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 			continue;
 		}
 
-		if (IS_ENABLED(CONFIG_IPV6)) {
-			const struct vxlan_config *cfg = &node->vxlan->cfg;
+		const struct vxlan_config *cfg = &node->vxlan->cfg;
 
+		if (IS_ENABLED(CONFIG_IPV6)) {
 			if ((cfg->flags & VXLAN_F_IPV6_LINKLOCAL) &&
 			    cfg->remote_ifindex != ifindex)
 				continue;
 		}
 
+		if (vni && !vxlan_addr_any(&cfg->remote_ip) &&
+		    !vxlan_addr_multicast(&cfg->remote_ip)) {
+			/* Get address from the outer IP header */
+			if (vxlan_get_sk_family(vs) == AF_INET) {
+				saddr.sin.sin_addr.s_addr = ip_hdr(skb)->saddr;
+				saddr.sa.sa_family = AF_INET;
+#if IS_ENABLED(CONFIG_IPV6)
+			} else {
+				saddr.sin6.sin6_addr = ipv6_hdr(skb)->saddr;
+				saddr.sa.sa_family = AF_INET6;
+#endif
+			}
+
+			if (!vxlan_addr_equal(&cfg->remote_ip, &saddr))
+				continue;
+		}
+
 		if (vninode)
 			*vninode = vnode;
 		return node->vxlan;
@@ -134,6 +153,7 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 
 /* Look up VNI in a per net namespace table */
 static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
+					const struct sk_buff *skb,
 					__be32 vni, sa_family_t family,
 					__be16 port, u32 flags)
 {
@@ -143,7 +163,7 @@ static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
 	if (!vs)
 		return NULL;
 
-	return vxlan_vs_find_vni(vs, ifindex, vni, NULL);
+	return vxlan_vs_find_vni(vs, ifindex, vni, skb, NULL);
 }
 
 /* Fill in neighbour message in skbuff. */
@@ -1701,7 +1721,7 @@ static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 
 	vni = vxlan_vni(vh->vx_vni);
 
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, &vninode);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, &vninode);
 	if (!vxlan) {
 		reason = SKB_DROP_REASON_VXLAN_VNI_NOT_FOUND;
 		goto drop;
@@ -1855,7 +1875,7 @@ static int vxlan_err_lookup(struct sock *sk, struct sk_buff *skb)
 		return -ENOENT;
 
 	vni = vxlan_vni(hdr->vx_vni);
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, NULL);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, NULL);
 	if (!vxlan)
 		return -ENOENT;
 
@@ -2330,7 +2350,7 @@ static int encap_bypass_if_local(struct sk_buff *skb, struct net_device *dev,
 		struct vxlan_dev *dst_vxlan;
 
 		dst_release(dst);
-		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, vni,
+		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, skb, vni,
 					   addr_family, dst_port,
 					   vxlan->cfg.flags);
 		if (!dst_vxlan) {
Signature · 1 line
2.39.2
author
#6 lore raw

RFC PATCH 2/3 vxlan: Do not treat vxlan dev as used when unicast remote_ip mismatches

In reply to Ted Chen

Do not treat a vxlan_dev as used if the vxlan to be configured shares the same vni as an existing vxlan_dev but has a different unicast remote_ip.

This enables multiple vxlan devices with distinct unicast remote_ips to be bound to a single vni.

---
 drivers/net/vxlan/vxlan_core.c | 4 ++++
 1 file changed, 4 insertions(+)
drivers/net/vxlan/vxlan_core.c +4 -0
index 3ca74a97c44f..5ef40ac816cc 100644
@@ -3723,6 +3723,10 @@ int vxlan_vni_in_use(struct net *src_net, struct vxlan_dev *vxlan,
 		} else if (tmp->cfg.vni != vni) {
 			continue;
 		}
+		if (!vxlan_addr_any(&conf->remote_ip) &&
+		    !vxlan_addr_multicast(&conf->remote_ip) &&
+		    !vxlan_addr_equal(&tmp->cfg.remote_ip, &conf->remote_ip))
+			continue;
 		if (tmp->cfg.dst_port != conf->dst_port)
 			continue;
 		if ((tmp->cfg.flags & (VXLAN_F_RCV_FLAGS | VXLAN_F_IPV6)) !=
Signature · 1 line
2.39.2
author
#7 lore raw

RFC PATCH 3/3 vxlan: vxlan_rcv(): Update comment to inlucde ipv6

In reply to Ted Chen

Update the comment to indicate that both ipv4/udp.c and ipv6/udp.c invoke vxlan_rcv() to process packets.

---
 drivers/net/vxlan/vxlan_core.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/net/vxlan/vxlan_core.c +1 -1
index 5ef40ac816cc..8bdf91d1fdfe 100644
@@ -1684,7 +1684,7 @@ static bool vxlan_ecn_decapsulate(struct vxlan_sock *vs, void *oiph,
 	return err <= 1;
 }
 
-/* Callback from net/ipv4/udp.c to receive packets */
+/* Callback from net/ipv{4,6}/udp.c to receive packets */
 static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 {
 	struct vxlan_vni_node *vninode = NULL;
Signature · 1 line
2.39.2
#2 lore raw

Re: [PATCH RFC net-next 1/3] vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and remote_ip

In reply to Ted Chen
Quoted 48 lines · Ted Chen

vxlan_vs_find_vni() currently searches the vni hash table in a vs and returns a vxlan_dev associated with the specified "vni". While this works when the remote_ips are stored in the vxlan fdb, it fails to handle the case where the remote_ip is just configured in the vxlan device outside of the vxlan fdb, because multiple vxlan devices with different remote_ip may share a single vni when the remote_ip is configured in the vxlan device (i.e., not stored in the vxlan fdb). In that case, further check of remote_ip to identify vxlan_dev more precisely.

---
 drivers/net/vxlan/vxlan_core.c | 32 ++++++++++++++++++++++++++------
 1 file changed, 26 insertions(+), 6 deletions(-)
drivers/net/vxlan/vxlan_core.c +9 -2
index 05c10acb2a57..3ca74a97c44f 100644
@@ -94,8 +94,10 @@ static struct vxlan_sock *vxlan_find_sock(struct net *net, sa_family_t family,
 
 static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 					   int ifindex, __be32 vni,
+					   const struct sk_buff *skb,
 					   struct vxlan_vni_node **vninode)
 {
+	union vxlan_addr saddr;
 	struct vxlan_vni_node *vnode;
 	struct vxlan_dev_node *node;
 
@@ -116,14 +118,31 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 			continue;
 		}
 
-		if (IS_ENABLED(CONFIG_IPV6)) {
-			const struct vxlan_config *cfg = &node->vxlan->cfg;
+		const struct vxlan_config *cfg = &node->vxlan->cfg;
 
+		if (IS_ENABLED(CONFIG_IPV6)) {
 			if ((cfg->flags & VXLAN_F_IPV6_LINKLOCAL) &&
 			    cfg->remote_ifindex != ifindex)
 				continue;
 		}
 
+		if (vni && !vxlan_addr_any(&cfg->remote_ip) &&
+		    !vxlan_addr_multicast(&cfg->remote_ip)) {
+			/* Get address from the outer IP header */
+			if (vxlan_get_sk_family(vs) == AF_INET) {
+				saddr.sin.sin_addr.s_addr = ip_hdr(skb)->saddr;

drivers/net/vxlan/vxlan_core.c static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs, · line 143

Quoted 10 lines
drivers/net/vxlan/vxlan_core.c +10 -0
+				saddr.sa.sa_family = AF_INET;
+#if IS_ENABLED(CONFIG_IPV6)
+			} else {
+				saddr.sin6.sin6_addr = ipv6_hdr(skb)->saddr;
+				saddr.sa.sa_family = AF_INET6;
+#endif
+			}
+
+			if (!vxlan_addr_equal(&cfg->remote_ip, &saddr))
+				continue;

This breaks existing behavior. Before this patch, a VXLAN device with a remote address could receive traffic from any VTEP (in the same broadcast domain).

I think this patch misinterprets the "remote" keyword as P2P when it is not the case. It is merely the VTEP to which packets are sent when no other VTEP was found in the FDB. A VXLAN device that was configured with the "remote" keyword can still send packets to other VTEPs and it should therefore be able to receive packets from them.

Quoted 53 lines
drivers/net/vxlan/vxlan_core.c +7 -4
+		}
+
 		if (vninode)
 			*vninode = vnode;
 		return node->vxlan;
@@ -134,6 +153,7 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 
 /* Look up VNI in a per net namespace table */
 static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
+					const struct sk_buff *skb,
 					__be32 vni, sa_family_t family,
 					__be16 port, u32 flags)
 {
@@ -143,7 +163,7 @@ static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
 	if (!vs)
 		return NULL;
 
-	return vxlan_vs_find_vni(vs, ifindex, vni, NULL);
+	return vxlan_vs_find_vni(vs, ifindex, vni, skb, NULL);
 }
 
 /* Fill in neighbour message in skbuff. */
@@ -1701,7 +1721,7 @@ static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 
 	vni = vxlan_vni(vh->vx_vni);
 
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, &vninode);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, &vninode);
 	if (!vxlan) {
 		reason = SKB_DROP_REASON_VXLAN_VNI_NOT_FOUND;
 		goto drop;
@@ -1855,7 +1875,7 @@ static int vxlan_err_lookup(struct sock *sk, struct sk_buff *skb)
 		return -ENOENT;
 
 	vni = vxlan_vni(hdr->vx_vni);
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, NULL);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, NULL);
 	if (!vxlan)
 		return -ENOENT;
 
@@ -2330,7 +2350,7 @@ static int encap_bypass_if_local(struct sk_buff *skb, struct net_device *dev,
 		struct vxlan_dev *dst_vxlan;
 
 		dst_release(dst);
-		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, vni,
+		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, skb, vni,
 					   addr_family, dst_port,
 					   vxlan->cfg.flags);
 		if (!dst_vxlan) {
Signature · 1 line
2.39.2
#8 lore raw

Re: [PATCH RFC net-next 3/3] vxlan: vxlan_rcv(): Update comment to inlucde ipv6

In reply to Ted Chen
Quoted 1 line · Ted Chen

Update the comment to indicate that both ipv4/udp.c and ipv6/udp.c invoke

Nit: net/ipv4/udp.c and net/ipv6/udp.c

Quoted 12 lines

vxlan_rcv() to process packets.

---
 drivers/net/vxlan/vxlan_core.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/net/vxlan/vxlan_core.c +0 -0
index 5ef40ac816cc..8bdf91d1fdfe 100644

drivers/net/vxlan/vxlan_core.c static bool vxlan_ecn_decapsulate(struct vxlan_sock *vs, void *oiph, · line 1687

Quoted 5 lines
drivers/net/vxlan/vxlan_core.c +1 -1
@@ -1684,7 +1684,7 @@ static bool vxlan_ecn_decapsulate(struct vxlan_sock *vs, void *oiph,
 	return err <= 1;
 }
 
-/* Callback from net/ipv4/udp.c to receive packets */
+/* Callback from net/ipv{4,6}/udp.c to receive packets */

Maybe just remove the comment? I don't see how anyone can find it useful.

Regardless, please submit this patch separately as it's not related to the other patches in the series.

Quoted 7 lines
drivers/net/vxlan/vxlan_core.c +0 -0
 static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 {
 	struct vxlan_vni_node *vninode = NULL;
Signature · 1 line
2.39.2
#11 lore raw
In reply to Ted Chen
Quoted 16 lines · Ted Chen

This RFC series proposes an implementation to enable the configuration of vxlan devices in a Hub-Spoke Network, allowing multiple vxlan devices to share the same VNI while being associated with different remote IPs under the same UDP port.

== Use case ==
In a Hub-Spoke Network, there is a central VTEP acting as the gateway, along with multiple outer VTEPs. Each outer VTEP communicates exclusively with the central VTEP and has no direct connection to other outer VTEPs. As a result, data exchanged between outer VTEPs must traverse the central VTEP. This design enhances security and enables centralized auditing and monitoring at the central VTEP.

== Existing methods ==
Currently, there are three methods to implement the use case.

Quoted 8 lines

Method 1:
The central VTEP establishes a separate vxlan tunnel with each outer VTEP, creating a vxlan device with a different VNI for each tunnel. All vxlan devices are then added to the same Linux bridge to enable forwarding.

Drawbacks: Complex configuration.
Each tenant requires multiple VNIs.

This looks like the most straightforward option to me.

Why do you view it as complex? Why multiple VNIs per tenant are a problem when we have 16M of them?

Quoted 19 lines

Method 2:
The central VTEP creates a single vxlan device using the same VNI, without configuring a remote IP. The IP addresses of all outer VTEPs are stored in the fdb. To enable forwarding, the vxlan device is added to a Linux bridge with hairpin mode enabled.

Drawbacks: unnecessary overhead or network anomalies
The hairpin mode may broadcast packets to all outer VTEPs, causing the source outer VTEP receiving packets it originally sent to the central VTEP. If the packet from the source outer VTEP is a broadcast packet, the broadcasting back of the packet can cause network anomalies.

Method 3:
The central VTEP uses the same VNI but different UDP ports to create a vxlan device for each outer VTEP, each tunneling to its corresponding outer VTEP. All the vxlan devices in the central VTEP are then added to the same Linux bridge to enable forwarding.

Quoted 7 lines

Drawbacks: complex configuration and potential security issues. Multiple UDP ports are required.

== Proposed implementation ==
In the central VTEP, each tenant only requires a single VNI, and all tenants share the same UDP port. This can avoid the drawbacks of the above three methods.

This method also has drawbacks. It breaks existing behavior (see my comment on patch #1) and it also bloats the VXLAN receive path.

I want to suggest an alternative which allows you to keep the existing topology (same VNI), but without kernel changes. The configuration of the outer VTEPs remains the same. The steps below are for the central VTEP.

First, create a VXLAN device in "external" mode. It will consume all the VNIs in a namespace, but you can limit it with the "vnifilter" keyword, if needed:

# ip -n ns_c link add name vx0 type vxlan dstport 4789 nolearning external
# tc -n ns_c qdisc add dev vx0 clsact

Then, for each outer VTEP, create a dummy device and enslave it to the bridge. Taking outer VTEP1 as an example:

# ip -n ns_c link add name dummy_vtep1 up master br0
# tc -n ns_c qdisc add dev dummy_vtep1 clsact

In order to demultiplex incoming VXLAN packets to the appropriate bridge member, use an ingress tc filter on the VXLAN device that matches on the encapsulating source IP (you can't do it w/o the "external" keyword) and redirects the traffic to the corresponding bridge member:

# tc -n ns_c filter add dev vx0 ingress pref 1 proto all \
	flower enc_key_id 42 enc_src_ip 10.0.0.1 \
	action mirred ingress redirect dev dummy_ns1

(add filters for other VTEPs with "pref 1" to avoid unnecessary lookups).

For Tx, on each bridge member, configure an egress tc filter that attaches tunnel metadata for the matching outer VTEP and redirects to the VXLAN device:

# tc -n ns_c filter add dev dummy_vtep1 egress pref 1 proto all \
	matchall \
	action tunnel_key set src_ip 10.0.0.3 dst_ip 10.0.0.1 id 42 dst_port 4789 \
	action mirred egress redirect dev vx0

The end result should be that the bridge forwards known unicast traffic to the appropriate outer VTEP and floods BUM traffic to all the outer VTEPs but the one from which the traffic was received.

Quoted 94 lines

As in below example,
- a tunnel is established between vxlan42.1 in the central VTEP and vxlan42 in the outer VTEP1:
ip link add vxlan42.1 type vxlan id 42 \

          local 10.0.0.3 remote 10.0.0.1 dstport 4789

- a tunnel is established between vxlan42.2 in the central VTEP and vxlan42 in the outer VTEP2:
ip link add vxlan42.2 type vxlan id 42 \
local 10.0.0.3 remote 10.0.0.2 dstport 4789

    ┌────────────────────────────────────────────┐
    │       ┌─────────────────────────┐  central │
    │       │          br0            │    VTEP  │
    │       └─┬────────────────────┬──┘          │
    │   ┌─────┴───────┐      ┌─────┴───────┐     │          
    │   │ vxlan42.1   │      │  vxlan42.2  │     │
    │   └─────────────┘      └─────────────┘     │  
    └───────────────────┬─┬──────────────────────┘
                        │ │ eth0 10.0.0.3:4789
                        │ │            
                        │ │            
       ┌────────────────┘ └───────────────┐
       │eth0 10.0.0.1:4789                │eth0 10.0.0.2:4789
 ┌─────┴───────┐                    ┌─────┴───────┐
 │outer VTEP1  │                    │outer VTEP2  │
 │     vxlan42 │                    │     vxlan42 │
 └─────────────┘                    └─────────────┘

== Test scenario ==
ip netns add ns_1
ip link add veth1 type veth peer name veth1-peer ip link set veth1 netns ns_1
ip netns exec ns_1 ip addr add 10.0.1.1/24 dev veth1 ip netns exec ns_1 ip link set veth1 up
ip netns exec ns_1 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_1 ip addr add 192.168.0.1/24 dev vxlan42 ip netns exec ns_1 ip link set up dev vxlan42

ip netns add ns_2
ip link add veth2 type veth peer name veth2-peer ip link set veth2 netns ns_2
ip netns exec ns_2 ip addr add 10.0.1.2/24 dev veth2 ip netns exec ns_2 ip link set veth2 up
ip netns exec ns_2 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_2 ip addr add 192.168.0.2/24 dev vxlan42 ip netns exec ns_2 ip link set up dev vxlan42

ip netns add ns_c
ip link add veth3 type veth peer name veth3-peer ip link set veth3 netns ns_c
ip netns exec ns_c ip addr add 10.0.1.3/24 dev veth3 ip netns exec ns_c ip link set veth3 up
ip netns exec ns_c ip link add vxlan42.1 type vxlan id 42 \

                   local 10.0.1.3 remote 10.0.1.1 dstport 4789
ip netns exec ns_c ip link add vxlan42.2 type vxlan id 42 \
                   local 10.0.1.3 remote 10.0.1.2 dstport 4789

ip netns exec ns_c ip link set up dev vxlan42.1 ip netns exec ns_c ip link set up dev vxlan42.2 ip netns exec ns_c ip link add name br0 type bridge ip netns exec ns_c ip link set br0 up
ip netns exec ns_c ip link set vxlan42.1 master br0 ip netns exec ns_c ip link set vxlan42.2 master br0

ip link add name br1 type bridge
ip link set br1 up
ip link set veth1-peer up
ip link set veth2-peer up
ip link set veth3-peer up
ip link set veth1-peer master br1
ip link set veth2-peer master br1
ip link set veth3-peer master br1

ip netns exec ns_1 ping 192.168.0.2 -I 192.168.0.1

Ted Chen (3):
vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and
remote_ip
vxlan: Do not treat vxlan dev as used when unicast remote_ip
mismatches
vxlan: vxlan_rcv(): Update comment to inlucde ipv6

 drivers/net/vxlan/vxlan_core.c | 38 +++++++++++++++++++++++++++-------
 1 file changed, 31 insertions(+), 7 deletions(-)
Signature · 1 line
2.39.2
author
#3 lore raw

Re: [PATCH RFC net-next 1/3] vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and remote_ip

In reply to Ido Schimmel
Quoted 64 lines · Ido Schimmel
Quoted 48 lines · Ted Chen

vxlan_vs_find_vni() currently searches the vni hash table in a vs and returns a vxlan_dev associated with the specified "vni". While this works when the remote_ips are stored in the vxlan fdb, it fails to handle the case where the remote_ip is just configured in the vxlan device outside of the vxlan fdb, because multiple vxlan devices with different remote_ip may share a single vni when the remote_ip is configured in the vxlan device (i.e., not stored in the vxlan fdb). In that case, further check of remote_ip to identify vxlan_dev more precisely.

---
 drivers/net/vxlan/vxlan_core.c | 32 ++++++++++++++++++++++++++------
 1 file changed, 26 insertions(+), 6 deletions(-)
drivers/net/vxlan/vxlan_core.c +9 -2
index 05c10acb2a57..3ca74a97c44f 100644
@@ -94,8 +94,10 @@ static struct vxlan_sock *vxlan_find_sock(struct net *net, sa_family_t family,
 
 static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 					   int ifindex, __be32 vni,
+					   const struct sk_buff *skb,
 					   struct vxlan_vni_node **vninode)
 {
+	union vxlan_addr saddr;
 	struct vxlan_vni_node *vnode;
 	struct vxlan_dev_node *node;
 
@@ -116,14 +118,31 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 			continue;
 		}
 
-		if (IS_ENABLED(CONFIG_IPV6)) {
-			const struct vxlan_config *cfg = &node->vxlan->cfg;
+		const struct vxlan_config *cfg = &node->vxlan->cfg;
 
+		if (IS_ENABLED(CONFIG_IPV6)) {
 			if ((cfg->flags & VXLAN_F_IPV6_LINKLOCAL) &&
 			    cfg->remote_ifindex != ifindex)
 				continue;
 		}
 
+		if (vni && !vxlan_addr_any(&cfg->remote_ip) &&
+		    !vxlan_addr_multicast(&cfg->remote_ip)) {
+			/* Get address from the outer IP header */
+			if (vxlan_get_sk_family(vs) == AF_INET) {
+				saddr.sin.sin_addr.s_addr = ip_hdr(skb)->saddr;

drivers/net/vxlan/vxlan_core.c static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs, · line 143

Quoted 10 lines
drivers/net/vxlan/vxlan_core.c +10 -0
+				saddr.sa.sa_family = AF_INET;
+#if IS_ENABLED(CONFIG_IPV6)
+			} else {
+				saddr.sin6.sin6_addr = ipv6_hdr(skb)->saddr;
+				saddr.sa.sa_family = AF_INET6;
+#endif
+			}
+
+			if (!vxlan_addr_equal(&cfg->remote_ip, &saddr))
+				continue;

This breaks existing behavior. Before this patch, a VXLAN device with a remote address could receive traffic from any VTEP (in the same broadcast domain).

Quoted 2 lines

I think this patch misinterprets the "remote" keyword as P2P when it is not the case. It is merely the VTEP to which packets are sent when no

Yes. Thanks for pointing that out.
I didn't see target addresses were appended into the FDB when an unicast remote_ip had been configured.

e.g.
Usually when (2)(3) are invoked, (1) is not called to configure a unicast remote_ip to the VTEP (though it's allowed to call (1)).

(1) ip link add vxlan42 type vxlan id 42 \

                local 10.0.0.1 remote 10.0.0.2 dstport 4789

(2) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.3 dev vxlan42
(3) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.4 dev vxlan42

So, this patch just leverages the case when remote_ip is configured in the VTEP to stand for P2P.

Do you think there's a better way to identify P2P more precisely?

Quoted 57 lines

other VTEP was found in the FDB. A VXLAN device that was configured with the "remote" keyword can still send packets to other VTEPs and it should therefore be able to receive packets from them.

Quoted 53 lines
drivers/net/vxlan/vxlan_core.c +7 -4
+		}
+
 		if (vninode)
 			*vninode = vnode;
 		return node->vxlan;
@@ -134,6 +153,7 @@ static struct vxlan_dev *vxlan_vs_find_vni(struct vxlan_sock *vs,
 
 /* Look up VNI in a per net namespace table */
 static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
+					const struct sk_buff *skb,
 					__be32 vni, sa_family_t family,
 					__be16 port, u32 flags)
 {
@@ -143,7 +163,7 @@ static struct vxlan_dev *vxlan_find_vni(struct net *net, int ifindex,
 	if (!vs)
 		return NULL;
 
-	return vxlan_vs_find_vni(vs, ifindex, vni, NULL);
+	return vxlan_vs_find_vni(vs, ifindex, vni, skb, NULL);
 }
 
 /* Fill in neighbour message in skbuff. */
@@ -1701,7 +1721,7 @@ static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 
 	vni = vxlan_vni(vh->vx_vni);
 
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, &vninode);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, &vninode);
 	if (!vxlan) {
 		reason = SKB_DROP_REASON_VXLAN_VNI_NOT_FOUND;
 		goto drop;
@@ -1855,7 +1875,7 @@ static int vxlan_err_lookup(struct sock *sk, struct sk_buff *skb)
 		return -ENOENT;
 
 	vni = vxlan_vni(hdr->vx_vni);
-	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, NULL);
+	vxlan = vxlan_vs_find_vni(vs, skb->dev->ifindex, vni, skb, NULL);
 	if (!vxlan)
 		return -ENOENT;
 
@@ -2330,7 +2350,7 @@ static int encap_bypass_if_local(struct sk_buff *skb, struct net_device *dev,
 		struct vxlan_dev *dst_vxlan;
 
 		dst_release(dst);
-		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, vni,
+		dst_vxlan = vxlan_find_vni(vxlan->net, dst_ifindex, skb, vni,
 					   addr_family, dst_port,
 					   vxlan->cfg.flags);
 		if (!dst_vxlan) {
Signature · 1 line
2.39.2
author
#9 lore raw

Re: [PATCH RFC net-next 3/3] vxlan: vxlan_rcv(): Update comment to inlucde ipv6

In reply to Ido Schimmel
Quoted 20 lines · Ido Schimmel
Quoted 1 line · Ted Chen

Update the comment to indicate that both ipv4/udp.c and ipv6/udp.c invoke

Nit: net/ipv4/udp.c and net/ipv6/udp.c

Quoted 15 lines

vxlan_rcv() to process packets.

---
 drivers/net/vxlan/vxlan_core.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/net/vxlan/vxlan_core.c +0 -0
index 5ef40ac816cc..8bdf91d1fdfe 100644
@@ -1684,7 +1684,7 @@ static bool vxlan_ecn_decapsulate(struct vxlan_sock *vs, void *oiph,
 	return err <= 1;
 }
 
Quoted 5 lines

drivers/net/vxlan/vxlan_core.c static bool vxlan_ecn_decapsulate(struct vxlan_sock *vs, void *oiph, · line 1687

Quoted 2 lines
drivers/net/vxlan/vxlan_core.c +1 -1
-/* Callback from net/ipv4/udp.c to receive packets */
+/* Callback from net/ipv{4,6}/udp.c to receive packets */

Maybe just remove the comment? I don't see how anyone can find it useful.

I'm ok with either way.
Please let me know if I need to send a separate one or the current one is fine.

Quoted 2 lines

Regardless, please submit this patch separately as it's not related to the other patches in the series.

I came across this comment when I wrote this series as I found vxlan_rcv() is called for both IPV4 and IPV6. Besides, I saw vxlan_err_lookup() has a similar comment.

Quoted 7 lines
Quoted 7 lines
drivers/net/vxlan/vxlan_core.c +0 -0
 static int vxlan_rcv(struct sock *sk, struct sk_buff *skb)
 {
 	struct vxlan_vni_node *vninode = NULL;
Signature · 1 line
2.39.2
author
#12 lore raw
In reply to Ido Schimmel
Quoted 23 lines · Ido Schimmel
Quoted 22 lines · Ted Chen

This RFC series proposes an implementation to enable the configuration of vxlan devices in a Hub-Spoke Network, allowing multiple vxlan devices to share the same VNI while being associated with different remote IPs under the same UDP port.

== Use case ==
In a Hub-Spoke Network, there is a central VTEP acting as the gateway, along with multiple outer VTEPs. Each outer VTEP communicates exclusively with the central VTEP and has no direct connection to other outer VTEPs. As a result, data exchanged between outer VTEPs must traverse the central VTEP. This design enhances security and enables centralized auditing and monitoring at the central VTEP.

== Existing methods ==
Currently, there are three methods to implement the use case.

Method 1:
The central VTEP establishes a separate vxlan tunnel with each outer VTEP, creating a vxlan device with a different VNI for each tunnel. All vxlan devices are then added to the same Linux bridge to enable forwarding.

Quoted 7 lines
Quoted 2 lines

Drawbacks: Complex configuration.
Each tenant requires multiple VNIs.

This looks like the most straightforward option to me.

Why do you view it as complex? Why multiple VNIs per tenant are a problem when we have 16M of them?

Yes, the issue is not due to a lack of VNIs.
IMO, using a single VNI within a single Layer 2 network is clearer and more intuitive.

Quoted 64 lines
Quoted 19 lines

Method 2:
The central VTEP creates a single vxlan device using the same VNI, without configuring a remote IP. The IP addresses of all outer VTEPs are stored in the fdb. To enable forwarding, the vxlan device is added to a Linux bridge with hairpin mode enabled.

Drawbacks: unnecessary overhead or network anomalies
The hairpin mode may broadcast packets to all outer VTEPs, causing the source outer VTEP receiving packets it originally sent to the central VTEP. If the packet from the source outer VTEP is a broadcast packet, the broadcasting back of the packet can cause network anomalies.

Method 3:
The central VTEP uses the same VNI but different UDP ports to create a vxlan device for each outer VTEP, each tunneling to its corresponding outer VTEP. All the vxlan devices in the central VTEP are then added to the same Linux bridge to enable forwarding.

Quoted 7 lines

Drawbacks: complex configuration and potential security issues. Multiple UDP ports are required.

== Proposed implementation ==
In the central VTEP, each tenant only requires a single VNI, and all tenants share the same UDP port. This can avoid the drawbacks of the above three methods.

This method also has drawbacks. It breaks existing behavior (see my comment on patch #1) and it also bloats the VXLAN receive path.

I want to suggest an alternative which allows you to keep the existing topology (same VNI), but without kernel changes. The configuration of the outer VTEPs remains the same. The steps below are for the central VTEP.

First, create a VXLAN device in "external" mode. It will consume all the VNIs in a namespace, but you can limit it with the "vnifilter" keyword, if needed:

# ip -n ns_c link add name vx0 type vxlan dstport 4789 nolearning external
# tc -n ns_c qdisc add dev vx0 clsact

Then, for each outer VTEP, create a dummy device and enslave it to the bridge. Taking outer VTEP1 as an example:

# ip -n ns_c link add name dummy_vtep1 up master br0
# tc -n ns_c qdisc add dev dummy_vtep1 clsact

In order to demultiplex incoming VXLAN packets to the appropriate bridge member, use an ingress tc filter on the VXLAN device that matches on the encapsulating source IP (you can't do it w/o the "external" keyword) and redirects the traffic to the corresponding bridge member:

# tc -n ns_c filter add dev vx0 ingress pref 1 proto all \
	flower enc_key_id 42 enc_src_ip 10.0.0.1 \
	action mirred ingress redirect dev dummy_ns1

(add filters for other VTEPs with "pref 1" to avoid unnecessary lookups).

For Tx, on each bridge member, configure an egress tc filter that attaches tunnel metadata for the matching outer VTEP and redirects to the VXLAN device:

Quoted 8 lines
# tc -n ns_c filter add dev dummy_vtep1 egress pref 1 proto all \
	matchall \
	action tunnel_key set src_ip 10.0.0.3 dst_ip 10.0.0.1 id 42 dst_port 4789 \
	action mirred egress redirect dev vx0

The end result should be that the bridge forwards known unicast traffic to the appropriate outer VTEP and floods BUM traffic to all the outer VTEPs but the one from which the traffic was received.

Cool!
I wasn’t aware that TC could be used in this way. Will give it a try.

Thanks a lot!

Quoted 94 lines
Quoted 94 lines

As in below example,
- a tunnel is established between vxlan42.1 in the central VTEP and vxlan42 in the outer VTEP1:
ip link add vxlan42.1 type vxlan id 42 \

          local 10.0.0.3 remote 10.0.0.1 dstport 4789

- a tunnel is established between vxlan42.2 in the central VTEP and vxlan42 in the outer VTEP2:
ip link add vxlan42.2 type vxlan id 42 \
local 10.0.0.3 remote 10.0.0.2 dstport 4789

    ┌────────────────────────────────────────────┐
    │       ┌─────────────────────────┐  central │
    │       │          br0            │    VTEP  │
    │       └─┬────────────────────┬──┘          │
    │   ┌─────┴───────┐      ┌─────┴───────┐     │          
    │   │ vxlan42.1   │      │  vxlan42.2  │     │
    │   └─────────────┘      └─────────────┘     │  
    └───────────────────┬─┬──────────────────────┘
                        │ │ eth0 10.0.0.3:4789
                        │ │            
                        │ │            
       ┌────────────────┘ └───────────────┐
       │eth0 10.0.0.1:4789                │eth0 10.0.0.2:4789
 ┌─────┴───────┐                    ┌─────┴───────┐
 │outer VTEP1  │                    │outer VTEP2  │
 │     vxlan42 │                    │     vxlan42 │
 └─────────────┘                    └─────────────┘

== Test scenario ==
ip netns add ns_1
ip link add veth1 type veth peer name veth1-peer ip link set veth1 netns ns_1
ip netns exec ns_1 ip addr add 10.0.1.1/24 dev veth1 ip netns exec ns_1 ip link set veth1 up
ip netns exec ns_1 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_1 ip addr add 192.168.0.1/24 dev vxlan42 ip netns exec ns_1 ip link set up dev vxlan42

ip netns add ns_2
ip link add veth2 type veth peer name veth2-peer ip link set veth2 netns ns_2
ip netns exec ns_2 ip addr add 10.0.1.2/24 dev veth2 ip netns exec ns_2 ip link set veth2 up
ip netns exec ns_2 ip link add vxlan42 type vxlan id 42 \

                   remote 10.0.1.3 dstport 4789

ip netns exec ns_2 ip addr add 192.168.0.2/24 dev vxlan42 ip netns exec ns_2 ip link set up dev vxlan42

ip netns add ns_c
ip link add veth3 type veth peer name veth3-peer ip link set veth3 netns ns_c
ip netns exec ns_c ip addr add 10.0.1.3/24 dev veth3 ip netns exec ns_c ip link set veth3 up
ip netns exec ns_c ip link add vxlan42.1 type vxlan id 42 \

                   local 10.0.1.3 remote 10.0.1.1 dstport 4789
ip netns exec ns_c ip link add vxlan42.2 type vxlan id 42 \
                   local 10.0.1.3 remote 10.0.1.2 dstport 4789

ip netns exec ns_c ip link set up dev vxlan42.1 ip netns exec ns_c ip link set up dev vxlan42.2 ip netns exec ns_c ip link add name br0 type bridge ip netns exec ns_c ip link set br0 up
ip netns exec ns_c ip link set vxlan42.1 master br0 ip netns exec ns_c ip link set vxlan42.2 master br0

ip link add name br1 type bridge
ip link set br1 up
ip link set veth1-peer up
ip link set veth2-peer up
ip link set veth3-peer up
ip link set veth1-peer master br1
ip link set veth2-peer master br1
ip link set veth3-peer master br1

ip netns exec ns_1 ping 192.168.0.2 -I 192.168.0.1

Ted Chen (3):
vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and
remote_ip
vxlan: Do not treat vxlan dev as used when unicast remote_ip
mismatches
vxlan: vxlan_rcv(): Update comment to inlucde ipv6

 drivers/net/vxlan/vxlan_core.c | 38 +++++++++++++++++++++++++++-------
 1 file changed, 31 insertions(+), 7 deletions(-)
Signature · 1 line
2.39.2
#4 lore raw

Re: [PATCH RFC net-next 1/3] vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and remote_ip

In reply to Ted Chen
Quoted 8 lines · Ted Chen

I didn't see target addresses were appended into the FDB when an unicast remote_ip had been configured.

e.g.
Usually when (2)(3) are invoked, (1) is not called to configure a unicast remote_ip to the VTEP (though it's allowed to call (1)).

(1) ip link add vxlan42 type vxlan id 42 \

Quoted 8 lines
                local 10.0.0.1 remote 10.0.0.2 dstport 4789

(2) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.3 dev vxlan42
(3) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.4 dev vxlan42

So, this patch just leverages the case when remote_ip is configured in the VTEP to stand for P2P.

Do you think there's a better way to identify P2P more precisely?

I think it will require a new uAPI (e.g., a new VXLAN netlink attribute) as it's a behavior change, but I really prefer not to go there when the problem can be solved in other ways (e.g., the tc solution I mentioned or using multiple VNIs).

#10 lore raw

Re: [PATCH RFC net-next 3/3] vxlan: vxlan_rcv(): Update comment to inlucde ipv6

In reply to Ted Chen
Quoted 3 lines · Ted Chen

I'm ok with either way.
Please let me know if I need to send a separate one or the current one is fine.

Yes, need to resend as a standalone patch.

Quoted 5 lines
Quoted 2 lines

Regardless, please submit this patch separately as it's not related to the other patches in the series.

I came across this comment when I wrote this series as I found vxlan_rcv() is called for both IPV4 and IPV6. Besides, I saw vxlan_err_lookup() has a similar comment.

OK, so it makes sense to adjust the comment like you did.

author
#5 lore raw

Re: [PATCH RFC net-next 1/3] vxlan: vxlan_vs_find_vni(): Find vxlan_dev according to vni and remote_ip

In reply to Ido Schimmel
Quoted 16 lines · Ido Schimmel
Quoted 15 lines · Ted Chen

I didn't see target addresses were appended into the FDB when an unicast remote_ip had been configured.

e.g.
Usually when (2)(3) are invoked, (1) is not called to configure a unicast remote_ip to the VTEP (though it's allowed to call (1)).

(1) ip link add vxlan42 type vxlan id 42 \

                local 10.0.0.1 remote 10.0.0.2 dstport 4789

(2) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.3 dev vxlan42
(3) bridge fdb append to 00:00:00:00:00:00 dst 10.0.0.4 dev vxlan42

So, this patch just leverages the case when remote_ip is configured in the VTEP to stand for P2P.

Quoted 6 lines
Quoted 1 line

Do you think there's a better way to identify P2P more precisely?

I think it will require a new uAPI (e.g., a new VXLAN netlink attribute) as it's a behavior change, but I really prefer not to go there when the problem can be solved in other ways (e.g., the tc solution I mentioned or using multiple VNIs).

I tried that the mentioned tc solution functions well in my required case. Thanks a lot!!