dt-bindings: clock: Convert silabs,si570 to DT schema
Subsystems (2)
Rob Herring (Arm)
maintainerPATCH 1/1 dt-bindings: clock: Convert silabs,si570 to DT schema
Convert the Silicon Labs SI570 binding to DT schema format. It's a straight-forward conversion.
Signed-off-by Rob Herring (Arm) <[email protected]>
--- .../bindings/clock/silabs,si570.txt | 41 ---------- .../bindings/clock/silabs,si570.yaml | 80 +++++++++++++++++++ 2 files changed, 80 insertions(+), 41 deletions(-) delete mode 100644 Documentation/devicetree/bindings/clock/silabs,si570.txt create mode 100644 Documentation/devicetree/bindings/clock/silabs,si570.yaml
Documentation/devicetree/bindings/clock/silabs,si570.txt deleted +0 -41
@@ -1,41 +0,0 @@ -Binding for Silicon Labs 570, 571, 598 and 599 programmable -I2C clock generators. - -Reference -This binding uses the common clock binding[1]. Details about the devices can be -found in the data sheets[2][3]. - -[1] Documentation/devicetree/bindings/clock/clock-bindings.txt -[2] Si570/571 Data Sheet - https://www.silabs.com/Support%20Documents/TechnicalDocs/si570.pdf -[3] Si598/599 Data Sheet - https://www.silabs.com/Support%20Documents/TechnicalDocs/si598-99.pdf - -Required properties: - - compatible: Shall be one of "silabs,si570", "silabs,si571", - "silabs,si598", "silabs,si599" - - reg: I2C device address. - - #clock-cells: From common clock bindings: Shall be 0. - - factory-fout: Factory set default frequency. This frequency is part specific. - The correct frequency for the part used has to be provided in - order to generate the correct output frequencies. For more - details, please refer to the data sheet. - - temperature-stability: Temperature stability of the device in PPM. Should be - one of: 7, 20, 50 or 100. - -Optional properties: - - clock-output-names: From common clock bindings. Recommended to be "si570". - - clock-frequency: Output frequency to generate. This defines the output - frequency set during boot. It can be reprogrammed during - runtime through the common clock framework. - - silabs,skip-recall: Do not perform NVM->RAM recall operation. It will rely - on hardware loading of RAM from NVM at power on. - -Example: - si570: clock-generator@5d { - #clock-cells = <0>; - compatible = "silabs,si570"; - temperature-stability = <50>; - reg = <0x5d>; - factory-fout = <156250000>; - };
Documentation/devicetree/bindings/clock/silabs,si570.yaml new file +80 -0
80 lines not on this page · raw message
Signature · 1 line
2.47.2
Quoted 4 lines · Rob Herring (Arm)
Convert the Silicon Labs SI570 binding to DT schema format. It's a straight-forward conversion.
Signed-off-by Rob Herring (Arm) <[email protected]>
Reviewed-by Krzysztof Kozlowski <[email protected]>
Best regards,
Krzysztof
Quoting Rob Herring (Arm) (2025-08-04 15:20:08)
Quoted 5 lines
Convert the Silicon Labs SI570 binding to DT schema format. It's a straight-forward conversion.
Signed-off-by Rob Herring (Arm) <[email protected]>---
Applied to clk-next