Skip to contentSkip to conversation

dt-bindings: thermal: Convert marvell,armada370-thermal to DT schema

PATCH In review Rob Herring (Arm) 2 participants 3 messages Aug 22, 2025 – Aug 24, 2025

Subsystems (2)
lore
Share & tools
lore

Rob Herring (Arm)

author maintainer
#0 lore raw

PATCH v2 1/1 dt-bindings: thermal: Convert marvell,armada370-thermal to DT schema

Convert the Marvell Armada 3xx/XP thermal binding to schema.

Drop the AP80x and CP110 as they have long been deprecated and have been replaced by a new binding.

---
v2:
- Indicate the 2nd reg entry is 8 bytes long only (dropping deprecated 4 bytes long).

---
 .../bindings/thermal/armada-thermal.txt       | 42 -------------------
 .../thermal/marvell,armada370-thermal.yaml    | 37 ++++++++++++++++
 2 files changed, 37 insertions(+), 42 deletions(-)
 delete mode 100644 Documentation/devicetree/bindings/thermal/armada-thermal.txt
 create mode 100644 Documentation/devicetree/bindings/thermal/marvell,armada370-thermal.yaml
Documentation/devicetree/bindings/thermal/armada-thermal.txt deleted +0 -42
deleted file mode 100644
index ab8b8fccc7af..000000000000
@@ -1,42 +0,0 @@
-* Marvell Armada 370/375/380/XP thermal management
-
-Required properties:
-
-- compatible: Should be set to one of the following:
-    * marvell,armada370-thermal
-    * marvell,armada375-thermal
-    * marvell,armada380-thermal
-    * marvell,armadaxp-thermal
-    * marvell,armada-ap806-thermal
-    * marvell,armada-ap807-thermal
-    * marvell,armada-cp110-thermal
-
-Note: these bindings are deprecated for AP806/CP110 and should instead
-follow the rules described in:
-Documentation/devicetree/bindings/arm/marvell/ap80x-system-controller.txt
-Documentation/devicetree/bindings/arm/marvell/cp110-system-controller.txt
-
-- reg: Device's register space.
-  Two entries are expected, see the examples below. The first one points
-  to the status register (4B). The second one points to the control
-  registers (8B).
-  Note: The compatibles marvell,armada370-thermal,
-  marvell,armada380-thermal, and marvell,armadaxp-thermal must point to
-  "control MSB/control 1", with size of 4 (deprecated binding), or point
-  to "control LSB/control 0" with size of 8 (current binding). All other
-  compatibles must point to "control LSB/control 0" with size of 8.
-
-Examples:
-
-	/* Legacy bindings */
-	thermal@d0018300 {
-		compatible = "marvell,armada370-thermal";
-		reg = <0xd0018300 0x4
-		       0xd0018304 0x4>;
-	};
-
-	ap_thermal: thermal@6f8084 {
-		compatible = "marvell,armada-ap806-thermal";
-		reg = <0x6f808C 0x4>,
-		      <0x6f8084 0x8>;
-	};
Documentation/devicetree/bindings/thermal/marvell,armada370-thermal.yaml new file +37 -0
new file mode 100644
index 000000000000..337792859448
@@ -0,0 +1,37 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/thermal/marvell,armada370-thermal.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Marvell Armada 3xx/XP thermal management
+
+maintainers:
+  - Miquel Raynal <[email protected]>
+
+properties:
+  compatible:
+    enum:
+      - marvell,armada370-thermal
+      - marvell,armada375-thermal
+      - marvell,armada380-thermal
+      - marvell,armadaxp-thermal
+
+  reg:
+    items:
+      - description: status register (4B)
+      - description: control register (8B)
+
+required:
+  - compatible
+  - reg
+
+additionalProperties: false
+
+examples:
+  - |
+    thermal@d0018300 {
+        compatible = "marvell,armada370-thermal";
+        reg = <0xd0018300 0x4>,
+              <0xd0018304 0x8>;
+    };
Signature · 1 line
2.50.1