tests/functional: collect more info in base.log file
PATCH 1/2 tests/functional: include logger name and function in messages
In reply to Daniel P. BerrangéAs we collect debug logs from a wide range of code it becomes increasingly confusing to understand where each log messages comes from. Adding "%(name)s" gives us the logger name, which is usually based on the python __name__ symbol, aka the code module name. Then "%(funcName)s" completes the story by identifying the function.
--- tests/functional/qemu_test/testcase.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
tests/functional/qemu_test/testcase.py +1 -1
@@ -217,7 +217,7 @@ def setUp(self): self._log_fh = logging.FileHandler(self.log_filename, mode='w') self._log_fh.setLevel(logging.DEBUG) fileFormatter = logging.Formatter( - '%(asctime)s - %(levelname)s: %(message)s') + '%(asctime)s - %(levelname)s: %(name)s.%(funcName)s %(message)s') self._log_fh.setFormatter(fileFormatter) self.log.addHandler(self._log_fh)
Signature · 1 line
2.51.1
cover tests/functional: collect more info in base.log file
This came about from looking at info in
https://gitlab.com/qemu-project/qemu/-/jobs/11877115717
where it appears we've hung in a QMP 'quit' command
but don't have conclusive proof since we're not capturing logs for qemu.qmp.
Daniel P. Berrangé (2):
tests/functional: include logger name and function in messages tests/functional: include the lower level QMP log messages
tests/functional/qemu_test/testcase.py | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-)
Signature · 1 line
2.51.1
PATCH 2/2 tests/functional: include the lower level QMP log messages
We've seen a GitLab CI timeout failure in the test_pseries.py test, where it appears likely that the test has hung in a self.qmp('quit') call, but we don't have conclusive proof. Adding the QMP log category to what we capture should help us diagnose this, at the cost of the base.log file becoming significantly more verbose. The previous commit to include the logger category name and function should at least help understanding the more verbose logs.
--- tests/functional/qemu_test/testcase.py | 4 ++++ 1 file changed, 4 insertions(+)
tests/functional/qemu_test/testcase.py +4 -0
@@ -225,6 +225,9 @@ def setUp(self): self.machinelog = logging.getLogger('qemu.machine') self.machinelog.setLevel(logging.DEBUG) self.machinelog.addHandler(self._log_fh) + self.qmplog = logging.getLogger('qemu.qmp') + self.qmplog.setLevel(logging.DEBUG) + self.qmplog.addHandler(self._log_fh) if not self.assets_available(): self.skipTest('One or more assets is not available')
@@ -235,6 +238,7 @@ def tearDown(self): if self.socketdir is not None: shutil.rmtree(self.socketdir.name) self.socketdir = None + self.qmplog.removeHandler(self._log_fh) self.machinelog.removeHandler(self._log_fh) self.log.removeHandler(self._log_fh) self._log_fh.close()
Signature · 1 line
2.51.1
Re: [PATCH 1/2] tests/functional: include logger name and function in messages
In reply to Daniel P. BerrangéQuoted 16 lines · Daniel P. Berrangé
As we collect debug logs from a wide range of code it becomes increasingly confusing to understand where each log messages comes from. Adding "%(name)s" gives us the logger name, which is usually based on the python
__name__symbol, aka the code module name. Then "%(funcName)s" completes the story by identifying the function.Signed-off-by Daniel P. Berrangé <[email protected]>--- tests/functional/qemu_test/testcase.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)tests/functional/qemu_test/testcase.py +0
-0
tests/functional/qemu_test/testcase.py def setUp(self): · line 223
Quoted 8 lines
tests/functional/qemu_test/testcase.py +1
-1@@ -217,7 +217,7 @@ def setUp(self): self._log_fh = logging.FileHandler(self.log_filename, mode='w') self._log_fh.setLevel(logging.DEBUG) fileFormatter = logging.Formatter( - '%(asctime)s - %(levelname)s: %(message)s') + '%(asctime)s - %(levelname)s: %(name)s.%(funcName)s %(message)s') self._log_fh.setFormatter(fileFormatter) self.log.addHandler(self._log_fh)
Re: [PATCH 2/2] tests/functional: include the lower level QMP log messages
In reply to Daniel P. BerrangéQuoted 28 lines · Daniel P. Berrangé
We've seen a GitLab CI timeout failure in the
test_pseries.pytest, where it appears likely that the test has hung in aself.qmp('quit')call, but we don't have conclusive proof. Adding the QMP log category to what we capture should help us diagnose this, at the cost of the base.log file becoming significantly more verbose. The previous commit to include the logger category name and function should at least help understanding the more verbose logs.Signed-off-by Daniel P. Berrangé <[email protected]>--- tests/functional/qemu_test/testcase.py | 4 ++++ 1 file changed, 4 insertions(+)tests/functional/qemu_test/testcase.py +3
-0@@ -225,6 +225,9 @@ def setUp(self): self.machinelog = logging.getLogger('qemu.machine') self.machinelog.setLevel(logging.DEBUG) self.machinelog.addHandler(self._log_fh) + self.qmplog = logging.getLogger('qemu.qmp') + self.qmplog.setLevel(logging.DEBUG) + self.qmplog.addHandler(self._log_fh) if not self.assets_available(): self.skipTest('One or more assets is not available')
tests/functional/qemu_test/testcase.py def tearDown(self): · line 244
Quoted 7 lines
tests/functional/qemu_test/testcase.py +1
-0@@ -235,6 +238,7 @@ def tearDown(self): if self.socketdir is not None: shutil.rmtree(self.socketdir.name) self.socketdir = None + self.qmplog.removeHandler(self._log_fh) self.machinelog.removeHandler(self._log_fh) self.log.removeHandler(self._log_fh) self._log_fh.close()
Hi,
I tested this patch, and now I'm seeing Python stack traces in the base.log, like this:
2025-10-29 07:22:45,264 - DEBUG: qemu.qmp.protocol.default._bh_loop_forever Task.Reader: failure: | Traceback (most recent call last): | File "../python/qemu/qmp/protocol.py", line 914, in _bh_loop_forever | await async_fn() | File "../python/qemu/qmp/protocol.py", line 952, in _bh_recv_message | msg = await self._recv() | ^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1053, in _recv | message = await self._do_recv() | ^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/qmp_client.py", line 459, in _do_recv | msg_bytes = await self._readline() | ^^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1021, in _readline | raise EOFError | EOFError
If if it's harmless, I think that's very confusing for the casual user when trying to debug a problem. Can we avoid these?
Or maybe rather log the qmp stuff into a separate file, e.g. qmp.log ?
Thomas
Re: [PATCH 2/2] tests/functional: include the lower level QMP log messages
Quoted 59 lines · Thomas Huth
Quoted 27 lines · Daniel P. Berrangé
We've seen a GitLab CI timeout failure in the
test_pseries.pytest, where it appears likely that the test has hung in aself.qmp('quit')call, but we don't have conclusive proof. Adding the QMP log category to what we capture should help us diagnose this, at the cost of the base.log file becoming significantly more verbose. The previous commit to include the logger category name and function should at least help understanding the more verbose logs.Signed-off-by Daniel P. Berrangé <[email protected]>--- tests/functional/qemu_test/testcase.py | 4 ++++ 1 file changed, 4 insertions(+)tests/functional/qemu_test/testcase.py +3
-0@@ -225,6 +225,9 @@ def setUp(self): self.machinelog = logging.getLogger('qemu.machine') self.machinelog.setLevel(logging.DEBUG) self.machinelog.addHandler(self._log_fh) + self.qmplog = logging.getLogger('qemu.qmp') + self.qmplog.setLevel(logging.DEBUG) + self.qmplog.addHandler(self._log_fh) if not self.assets_available(): self.skipTest('One or more assets is not available')tests/functional/qemu_test/testcase.py def tearDown(self): · line 244
Quoted 7 lines
tests/functional/qemu_test/testcase.py +1
-0@@ -235,6 +238,7 @@ def tearDown(self): if self.socketdir is not None: shutil.rmtree(self.socketdir.name) self.socketdir = None + self.qmplog.removeHandler(self._log_fh) self.machinelog.removeHandler(self._log_fh) self.log.removeHandler(self._log_fh) self._log_fh.close()Hi,
I tested this patch, and now I'm seeing Python stack traces in the base.log, like this:
2025-10-29 07:22:45,264 - DEBUG: qemu.qmp.protocol.default._bh_loop_forever Task.Reader: failure: | Traceback (most recent call last): | File "../python/qemu/qmp/protocol.py", line 914, in _bh_loop_forever | await async_fn() | File "../python/qemu/qmp/protocol.py", line 952, in _bh_recv_message | msg = await self._recv() | ^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1053, in _recv | message = await self._do_recv() | ^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/qmp_client.py", line 459, in _do_recv | msg_bytes = await self._readline() | ^^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1021, in _readline | raise EOFError | EOFError
Quoted 2 lines
If if it's harmless, I think that's very confusing for the casual user when trying to debug a problem. Can we avoid these?
That comes from this code in qemu/qmp/protocol.py
except BaseException as err:
self.logger.log(
logging.INFO if isinstance(err, EOFError) else logging.ERROR,
"Task.%s: %s",
name, exception_summary(err)
)
self.logger.debug("Task.%s: failure:\n%s\n",
name, pretty_traceback())
self._schedule_disconnect()
raiseGiven EOF is a "normal" thing, I'm not convinced it justifies printing a traceback. I'd be inclined to suggest a new "except EOFError" clause that catches that normal exception and thus skips the traceback.
I don't think we need to block this patch waiting for that improvement though. When collecting DEBUG logs there are always going to be weird things like this present, and anything misleading just needs to be fixed when we uncover it.
Quoted 1 line
Or maybe rather log the qmp stuff into a separate file, e.g. qmp.log ?
I really don't want separate files for different log categories, as then you have created a problem of merging the two files in order to interpret the flow. That doesn't doesn't scale as we capture yet more log categories.
With regards,
Daniel
Signature · 3 lines
|: https://berrange.com -o- https://www.flickr.com/photos/dberrange :| |: https://libvirt.org -o- https://fstop138.berrange.com :| |: https://entangle-photo.org -o- https://www.instagram.com/dberrange :|
Thomas Huth
Reviewed-byRe: [PATCH 2/2] tests/functional: include the lower level QMP log messages
Quoted 76 lines · Daniel P. Berrangé
Quoted 59 lines · Thomas Huth
Quoted 27 lines · Daniel P. Berrangé
We've seen a GitLab CI timeout failure in the
test_pseries.pytest, where it appears likely that the test has hung in aself.qmp('quit')call, but we don't have conclusive proof. Adding the QMP log category to what we capture should help us diagnose this, at the cost of the base.log file becoming significantly more verbose. The previous commit to include the logger category name and function should at least help understanding the more verbose logs.Signed-off-by Daniel P. Berrangé <[email protected]>--- tests/functional/qemu_test/testcase.py | 4 ++++ 1 file changed, 4 insertions(+)tests/functional/qemu_test/testcase.py +3
-0@@ -225,6 +225,9 @@ def setUp(self): self.machinelog = logging.getLogger('qemu.machine') self.machinelog.setLevel(logging.DEBUG) self.machinelog.addHandler(self._log_fh) + self.qmplog = logging.getLogger('qemu.qmp') + self.qmplog.setLevel(logging.DEBUG) + self.qmplog.addHandler(self._log_fh) if not self.assets_available(): self.skipTest('One or more assets is not available')tests/functional/qemu_test/testcase.py def tearDown(self): · line 244
Quoted 7 lines
tests/functional/qemu_test/testcase.py +1
-0@@ -235,6 +238,7 @@ def tearDown(self): if self.socketdir is not None: shutil.rmtree(self.socketdir.name) self.socketdir = None + self.qmplog.removeHandler(self._log_fh) self.machinelog.removeHandler(self._log_fh) self.log.removeHandler(self._log_fh) self._log_fh.close()Hi,
I tested this patch, and now I'm seeing Python stack traces in the base.log, like this:
2025-10-29 07:22:45,264 - DEBUG: qemu.qmp.protocol.default._bh_loop_forever Task.Reader: failure: | Traceback (most recent call last): | File "../python/qemu/qmp/protocol.py", line 914, in _bh_loop_forever | await async_fn() | File "../python/qemu/qmp/protocol.py", line 952, in _bh_recv_message | msg = await self._recv() | ^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1053, in _recv | message = await self._do_recv() | ^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/qmp_client.py", line 459, in _do_recv | msg_bytes = await self._readline() | ^^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1021, in _readline | raise EOFError | EOFErrorQuoted 2 lines
If if it's harmless, I think that's very confusing for the casual user when trying to debug a problem. Can we avoid these?
That comes from this code in
qemu/qmp/protocol.pyexcept BaseException as err: self.logger.log( logging.INFO if isinstance(err, EOFError) else logging.ERROR, "Task.%s: %s", name, exception_summary(err) ) self.logger.debug("Task.%s: failure:\n%s\n", name, pretty_traceback()) self._schedule_disconnect() raise
Quoted 3 lines
Given EOF is a "normal" thing, I'm not convinced it justifies printing a traceback. I'd be inclined to suggest a new "except EOFError" clause that catches that normal exception and thus skips the traceback.
Sounds reasonable, could you please send a patch for qemu.qmp?
Quoted 4 lines
I don't think we need to block this patch waiting for that improvement though. When collecting DEBUG logs there are always going to be weird things like this present, and anything misleading just needs to be fixed when we uncover it.
Ack.
Quoted 5 lines
Quoted 1 line
Or maybe rather log the qmp stuff into a separate file, e.g. qmp.log ?
I really don't want separate files for different log categories, as then you have created a problem of merging the two files in order to interpret the flow. That doesn't doesn't scale as we capture yet more log categories.
Ok, fine with me, we still can refine later if we feel that it is necessary. So:
I'll queue this for my next pull request.
Thomas
Re: [PATCH 2/2] tests/functional: include the lower level QMP log messages
Quoted 77 lines · Thomas Huth
Quoted 76 lines · Daniel P. Berrangé
Quoted 59 lines · Thomas Huth
Quoted 27 lines · Daniel P. Berrangé
We've seen a GitLab CI timeout failure in the
test_pseries.pytest, where it appears likely that the test has hung in aself.qmp('quit')call, but we don't have conclusive proof. Adding the QMP log category to what we capture should help us diagnose this, at the cost of the base.log file becoming significantly more verbose. The previous commit to include the logger category name and function should at least help understanding the more verbose logs.Signed-off-by Daniel P. Berrangé <[email protected]>--- tests/functional/qemu_test/testcase.py | 4 ++++ 1 file changed, 4 insertions(+)tests/functional/qemu_test/testcase.py +3
-0@@ -225,6 +225,9 @@ def setUp(self): self.machinelog = logging.getLogger('qemu.machine') self.machinelog.setLevel(logging.DEBUG) self.machinelog.addHandler(self._log_fh) + self.qmplog = logging.getLogger('qemu.qmp') + self.qmplog.setLevel(logging.DEBUG) + self.qmplog.addHandler(self._log_fh) if not self.assets_available(): self.skipTest('One or more assets is not available')tests/functional/qemu_test/testcase.py def tearDown(self): · line 244
Quoted 7 lines
tests/functional/qemu_test/testcase.py +1
-0@@ -235,6 +238,7 @@ def tearDown(self): if self.socketdir is not None: shutil.rmtree(self.socketdir.name) self.socketdir = None + self.qmplog.removeHandler(self._log_fh) self.machinelog.removeHandler(self._log_fh) self.log.removeHandler(self._log_fh) self._log_fh.close()Hi,
I tested this patch, and now I'm seeing Python stack traces in the base.log, like this:
2025-10-29 07:22:45,264 - DEBUG: qemu.qmp.protocol.default._bh_loop_forever Task.Reader: failure: | Traceback (most recent call last): | File "../python/qemu/qmp/protocol.py", line 914, in _bh_loop_forever | await async_fn() | File "../python/qemu/qmp/protocol.py", line 952, in _bh_recv_message | msg = await self._recv() | ^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1053, in _recv | message = await self._do_recv() | ^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/qmp_client.py", line 459, in _do_recv | msg_bytes = await self._readline() | ^^^^^^^^^^^^^^^^^^^^^^ | File "../python/qemu/qmp/protocol.py", line 1021, in _readline | raise EOFError | EOFErrorQuoted 2 lines
If if it's harmless, I think that's very confusing for the casual user when trying to debug a problem. Can we avoid these?
That comes from this code in
qemu/qmp/protocol.pyexcept BaseException as err: self.logger.log( logging.INFO if isinstance(err, EOFError) else logging.ERROR, "Task.%s: %s", name, exception_summary(err) ) self.logger.debug("Task.%s: failure:\n%s\n", name, pretty_traceback()) self._schedule_disconnect() raise
Quoted 5 lines
Quoted 3 lines
Given EOF is a "normal" thing, I'm not convinced it justifies printing a traceback. I'd be inclined to suggest a new "except EOFError" clause that catches that normal exception and thus skips the traceback.
Sounds reasonable, could you please send a patch for qemu.qmp?
https://gitlab.com/qemu-project/python-qemu-qmp/-/merge_requests/46
With regards,
Daniel
Signature · 3 lines
|: https://berrange.com -o- https://www.flickr.com/photos/dberrange :| |: https://libvirt.org -o- https://fstop138.berrange.com :| |: https://entangle-photo.org -o- https://www.instagram.com/dberrange :|