soc: qcom: aoss: avoid registering cooling for NULL cdev
Subsystems (2)
PATCH 1/1 soc: qcom: aoss: avoid registering cooling for NULL cdev
When PTR_ERR_OR_ZERO points to NULL, it returns 0. In this case, if (ret) does not meet expectations. Now, qmp_cooling_device_add returns NODEV for both failure and NULL, and returns 0 for success.
Signed-off-by Haris Wu <[email protected]>
--- drivers/soc/qcom/qcom_aoss.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)
drivers/soc/qcom/qcom_aoss.c +4 -2
@@ -386,11 +386,13 @@ static int qmp_cooling_device_add(struct qmp *qmp, cdev_name, qmp_cdev, &qmp_cooling_device_ops); -if (IS_ERR (qmp_cdev->cdev)) +if (IS_ERR_OR_NULL (qmp_cdev->cdev)) {dev_err (qmp->dev,"unable to register %s cooling device\n" , cdev_name); +return -ENODEV ; + } -return PTR_ERR_OR_ZERO (qmp_cdev->cdev); +return 0 ; }static int qmp_cooling_devices_register (struct qmp *qmp)
Signature · 1 line
2.47.3
Dmitry Baryshkov
NAKQuoted 8 lines · Haris Wu
When
PTR_ERR_OR_ZEROpoints to NULL, it returns 0. In this case, if (ret) does not meet expectations. Now,qmp_cooling_device_addreturns NODEV for both failure and NULL, and returns 0 for success.Signed-off-by Haris Wu <[email protected]>--- drivers/soc/qcom/qcom_aoss.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)
NAK, devm_thermal_of_cooling_device_register() can't return NULL. It returns either a valid device pointer or an error pointer.
Quoted 24 lines
drivers/soc/qcom/qcom_aoss.c +4
-2@@ -386,11 +386,13 @@ static int qmp_cooling_device_add(struct qmp *qmp, cdev_name, qmp_cdev, &qmp_cooling_device_ops); -if (IS_ERR (qmp_cdev->cdev)) +if (IS_ERR_OR_NULL (qmp_cdev->cdev)) {dev_err (qmp->dev,"unable to register %s cooling device\n" , cdev_name); +return -ENODEV ; + } -return PTR_ERR_OR_ZERO (qmp_cdev->cdev); +return 0 ; }static int qmp_cooling_devices_register (struct qmp *qmp)Signature · 1 line
2.47.3
Signature · 2 lines
With best wishes Dmitry