PATCH v3 1/1 net/netvsc: switch data path to synthetic on device stop

When DPDK stops a netvsc device (e.g. on testpmd quit), the data path was left pointing to the VF/MANA device. If the kernel netvsc driver subsequently reloads the MANA device and opens it, incoming traffic arrives on the MANA device immediately, before the queues are fully initialized. This causes bogus RX completion events to appear on the TX completion queue, triggering a kernel WARNING in mana_poll_tx_cq().

Fix this by switching the data path back to synthetic (via NVS_DATAPATH_SYNTHETIC) in hn_vf_stop() before stopping the VF device. This tells the host to route traffic through the synthetic path, so that when the MANA driver recreates its queues, no unexpected traffic arrives until netvsc explicitly switches back to VF.

Also update hn_vf_start() to switch the data path back to VF after the VF device is started, enabling correct stop/start cycling.

Both functions now use write locks instead of read locks since they modify vf_vsc_switched state.

Fixes dc7680e8597c ("net/netvsc: support integrated VF")

---
v3:
- Preserve datapath switch error in hn_vf_stop() by using a separate variable for rte_eth_dev_stop() return value; return the first error encountered.

v2:
- In hn_vf_stop(), only clear vf_vsc_switched on successful datapath switch (not unconditionally).
- In hn_vf_start(), stop the VF device if datapath switch to VF fails after successful VF start.

 drivers/net/netvsc/hn_vf.c | 65 ++++++++++++++++++++++++++++++++------
 1 file changed, 55 insertions(+), 10 deletions(-)
drivers/net/netvsc/hn_vf.c +55 -10
index 99e8086afa..1fcc65a712 100644
@@ -314,9 +314,17 @@ int hn_vf_add_unlocked(struct rte_eth_dev *dev, struct hn_data *hv)
 	}
 
 switch_data_path:
-	ret = hn_nvs_set_datapath(hv, NVS_DATAPATH_VF);
-	if (ret == 0)
-		hv->vf_ctx.vf_vsc_switched = true;
+	/* Only switch data path to VF if the device is started.
+	 * Otherwise defer to hn_vf_start() to avoid routing traffic
+	 * to the VF before queues are set up.
+	 */
+	if (dev->data->dev_started) {
+		ret = hn_nvs_set_datapath(hv, NVS_DATAPATH_VF);
+		if (ret)
+			PMD_DRV_LOG(ERR, "Failed to switch to VF: %d", ret);
+		else
+			hv->vf_ctx.vf_vsc_switched = true;
+	}
 
 exit:
 	return ret;
@@ -521,11 +529,31 @@ int hn_vf_start(struct rte_eth_dev *dev)
 	struct rte_eth_dev *vf_dev;
 	int ret = 0;
 
-	rte_rwlock_read_lock(&hv->vf_lock);
+	rte_rwlock_write_lock(&hv->vf_lock);
 	vf_dev = hn_get_vf_dev(hv);
-	if (vf_dev)
+	if (vf_dev) {
 		ret = rte_eth_dev_start(vf_dev->data->port_id);
-	rte_rwlock_read_unlock(&hv->vf_lock);
+		if (ret == 0) {
+			/* Re-switch data path to VF if VSP has reported
+			 * VF is present and we haven't switched yet
+			 * (e.g. after a stop/start cycle).
+			 */
+			if (hv->vf_ctx.vf_vsp_reported &&
+			    !hv->vf_ctx.vf_vsc_switched) {
+				ret = hn_nvs_set_datapath(hv,
+							  NVS_DATAPATH_VF);
+				if (ret) {
+					PMD_DRV_LOG(ERR,
+						    "Failed to switch to VF: %d",
+						    ret);
+					rte_eth_dev_stop(vf_dev->data->port_id);
+				} else {
+					hv->vf_ctx.vf_vsc_switched = true;
+				}
+			}
+		}
+	}
+	rte_rwlock_write_unlock(&hv->vf_lock);
 	return ret;
 }
 
@@ -534,16 +562,33 @@ int hn_vf_stop(struct rte_eth_dev *dev)
 	struct hn_data *hv = dev->data->dev_private;
 	struct rte_eth_dev *vf_dev;
 	int ret = 0;
+	int err;
 
-	rte_rwlock_read_lock(&hv->vf_lock);
+	rte_rwlock_write_lock(&hv->vf_lock);
 	vf_dev = hn_get_vf_dev(hv);
 	if (vf_dev) {
-		ret = rte_eth_dev_stop(vf_dev->data->port_id);
-		if (ret != 0)
+		/* Switch data path back to synthetic before stopping VF,
+		 * so the host stops routing traffic to the VF device.
+		 */
+		if (hv->vf_ctx.vf_vsc_switched) {
+			ret = hn_nvs_set_datapath(hv, NVS_DATAPATH_SYNTHETIC);
+			if (ret) {
+				PMD_DRV_LOG(ERR,
+					    "Failed to switch to synthetic: %d",
+					    ret);
+			} else {
+				hv->vf_ctx.vf_vsc_switched = false;
+			}
+		}
+
+		err = rte_eth_dev_stop(vf_dev->data->port_id);
+		if (err != 0)
 			PMD_DRV_LOG(ERR, "Failed to stop device on port %u",
 				    vf_dev->data->port_id);
+		if (ret == 0)
+			ret = err;
 	}
-	rte_rwlock_read_unlock(&hv->vf_lock);
+	rte_rwlock_write_unlock(&hv->vf_lock);
 
 	return ret;
 }
Signature · 1 line
2.43.0
#1 lore raw
Quoted 16 lines · On Wed, 25 Mar 2026 11:57:50 -0700 Long Li <[email protected]> wrote:

When DPDK stops a netvsc device (e.g. on testpmd quit), the data path was left pointing to the VF/MANA device. If the kernel netvsc driver subsequently reloads the MANA device and opens it, incoming traffic arrives on the MANA device immediately, before the queues are fully initialized. This causes bogus RX completion events to appear on the TX completion queue, triggering a kernel WARNING in mana_poll_tx_cq().

Fix this by switching the data path back to synthetic (via NVS_DATAPATH_SYNTHETIC) in hn_vf_stop() before stopping the VF device. This tells the host to route traffic through the synthetic path, so that when the MANA driver recreates its queues, no unexpected traffic arrives until netvsc explicitly switches back to VF.

Also update hn_vf_start() to switch the data path back to VF after the VF device is started, enabling correct stop/start cycling.

Quoted 8 lines

Both functions now use write locks instead of read locks since they modify vf_vsc_switched state.

Fixes dc7680e8597c ("net/netvsc: support integrated VF")

---

Looks good applied to next-net