xfs: don't flush and invalidate internal RT device twice in xfs_shutdown_devices
PATCH 1/1 xfs: don't flush and invalidate internal RT device twice in xfs_shutdown_devices
Check for an internal RT device to remove a bit of extra work.
Fixes bdc03eb5f98f ("xfs: allow internal RT devices for zoned mode")
Signed-off-by Christoph Hellwig <[email protected]>
--- fs/xfs/xfs_super.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
fs/xfs/xfs_super.c +1 -1
@@ -445,7 +445,7 @@ xfs_shutdown_devices(blkdev_issue_flush (mp->m_logdev_targp->bt_bdev);invalidate_bdev (mp->m_logdev_targp->bt_bdev); } -if (mp->m_rtdev_targp) { +if (mp->m_rtdev_targp && mp->m_rtdev_targp != mp->m_ddev_targp) {blkdev_issue_flush (mp->m_rtdev_targp->bt_bdev);invalidate_bdev (mp->m_rtdev_targp->bt_bdev); }
Signature · 1 line
2.53.0
Quoted 4 lines · Christoph Hellwig
Check for an internal RT device to remove a bit of extra work.
Fixes bdc03eb5f98f ("xfs: allow internal RT devices for zoned mode")Signed-off-by Christoph Hellwig <[email protected]>
Looks good.
Reviewed-by Carlos Maiolino <[email protected]>
Quoted 21 lines
--- fs/xfs/xfs_super.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)fs/xfs/xfs_super.c +1
-1@@ -445,7 +445,7 @@ xfs_shutdown_devices(blkdev_issue_flush (mp->m_logdev_targp->bt_bdev);invalidate_bdev (mp->m_logdev_targp->bt_bdev); } -if (mp->m_rtdev_targp) { +if (mp->m_rtdev_targp && mp->m_rtdev_targp != mp->m_ddev_targp) {blkdev_issue_flush (mp->m_rtdev_targp->bt_bdev);invalidate_bdev (mp->m_rtdev_targp->bt_bdev); }Signature · 1 line
2.53.0
Quoted 13 lines · Christoph Hellwig
Check for an internal RT device to remove a bit of extra work.
Fixes bdc03eb5f98f ("xfs: allow internal RT devices for zoned mode")Signed-off-by Christoph Hellwig <[email protected]>--- fs/xfs/xfs_super.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)fs/xfs/xfs_super.c +0
-0
fs/xfs/xfs_super.c xfs_shutdown_devices( · line 451
Quoted 8 lines
fs/xfs/xfs_super.c +1
-1@@ -445,7 +445,7 @@ xfs_shutdown_devices(blkdev_issue_flush (mp->m_logdev_targp->bt_bdev);invalidate_bdev (mp->m_logdev_targp->bt_bdev); } -if (mp->m_rtdev_targp) { +if (mp->m_rtdev_targp && mp->m_rtdev_targp != mp->m_ddev_targp) {blkdev_issue_flush (mp->m_rtdev_targp->bt_bdev);invalidate_bdev (mp->m_rtdev_targp->bt_bdev); }
Looks good too.
Reviewed-by Carlos Maiolino <[email protected]>
Quoted 4 lines
Signature · 1 line
2.53.0
Quoted 3 lines · Christoph Hellwig
Check for an internal RT device to remove a bit of extra work.
Applied to for-next, thanks!
[1/1] xfs: don't flush and invalidate internal RT device twice in xfs_shutdown_devices
commit: 7fc296b379edc0fef83890097af3c9537fbf4364
Best regards,
Signature · 1 line