PATCH 1/1 PCI: pciehp: Add PLX quirk for missing Command Completed events

All PLX PEX 8600- and 8700-series data books say the Command Completed bit is set only after the Hot Plug Controller completes a command that changes the Attention Indicator Control, Power Indicator Control, Power Controller Control, or Electromechanical Interlock Control fields. It is not set after writes that only change the Presence Detect Changed Enable or Command Completed Interrupt Enable bits.

Consequently, pciehp waits for Command Completed after changing these notification Enable bits and logs a timeout.

This behavior exactly matches the conditions described when quirk_cmd_compl() was first added: both controllers report completion only when the same four Control fields change and fail to report completion for notification Enable-only writes.

Add only the PLX PEX 8600- and 8700-series switches on which this fix was tested to quirk_cmd_compl(). This makes pciehp mark Enable-only writes complete immediately while continuing to wait for commands that change Control fields.

---
 drivers/pci/hotplug/pciehp_hpc.c | 14 ++++++++++++++
 1 file changed, 14 insertions(+)
drivers/pci/hotplug/pciehp_hpc.c +14 -0
index 4c62140a3..5450aa6c7 100644
@@ -1122,3 +1122,17 @@ DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_QCOM, 0x0401,
 			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
 DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_HXT, 0x0401,
 			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8717,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8725,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8749,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8604,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8608,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8609,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8614,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);

base-commit: 5dd1818b15d98d4a20806cd00b1b40320b06004f

Signature · 1 line
2.51.0
#1 lore raw
Sashiko has reviewed this patch and found no issues. It looks great!
Quoted 15 lines

All PLX PEX 8600- and 8700-series data books say the Command Completed bit is set only after the Hot Plug Controller completes a command that changes the Attention Indicator Control, Power Indicator Control, Power Controller Control, or Electromechanical Interlock Control fields. It is not set after writes that only change the Presence Detect Changed Enable or Command Completed Interrupt Enable bits.

Consequently, pciehp waits for Command Completed after changing these notification Enable bits and logs a timeout.

This behavior exactly matches the conditions described when quirk_cmd_compl() was first added: both controllers report completion only when the same four Control fields change and fail to report completion for notification Enable-only writes.

Quoted 6 lines

Add only the PLX PEX 8600- and 8700-series switches on which this fix was tested to quirk_cmd_compl(). This makes pciehp mark Enable-only writes complete immediately while continuing to wait for commands that change Control fields.

Sashiko has reviewed this patch and found no issues. It looks great!

Signature · 1 line
Sashiko AI review · https://sashiko.dev/#/patchset/[email protected]?part=1
#2 lore raw

PATCH v2 1/1 PCI: pciehp: Add PLX 8600/8700 quirk for missing Command Completed events

All PLX PEX 8600- and 8700-series data books say the Command Completed bit is set only after the Hot Plug Controller completes a command that changes the Attention Indicator Control, Power Indicator Control, Power Controller Control, or Electromechanical Interlock Control fields. It is not set after writes that only change the Presence Detect Changed Enable or Command Completed Interrupt Enable bits.

Consequently, pciehp waits for Command Completed after changing these notification Enable bits and logs a timeout, for example:

pcieport 0000:90:02.0: pciehp: Timeout on hotplug command 0x07c0 (issued 2032 msec ago)

Like the controllers already handled by quirk_cmd_compl(), these PLX switches report completion only when the same four Control fields change and fail to report completion for notification Enable-only writes.

Add only the PLX PEX 8600- and 8700-series switches on which this fix was tested to quirk_cmd_compl(). This makes pciehp mark Enable-only writes complete immediately while continuing to wait for commands that change Control fields.

---
Changes in v2:
- Mention the PLX 8600/8700 series in the subject.
- Include an example of the hotplug command timeout.
- List the PLX device IDs in ascending order.
- Clarify the comparison with existing quirks and wrap the log example.
- Base the patch on the PCI maintainer tree's next branch.

Base tree: https://git.kernel.org/pub/scm/linux/kernel/git/pci/pci.git (next)

 drivers/pci/hotplug/pciehp_hpc.c | 14 ++++++++++++++
 1 file changed, 14 insertions(+)
drivers/pci/hotplug/pciehp_hpc.c +14 -0
index 4c62140a3..e48e140ba 100644
@@ -1122,3 +1122,17 @@ DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_QCOM, 0x0401,
 			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
 DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_HXT, 0x0401,
 			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8604,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8608,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8609,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8614,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8717,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8725,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);
+DECLARE_PCI_FIXUP_CLASS_EARLY(PCI_VENDOR_ID_PLX, 0x8749,
+			      PCI_CLASS_BRIDGE_PCI, 8, quirk_cmd_compl);

base-commit: 732c4f7d2c04f8c175d85d9243213783ee024ebc

Signature · 1 line
2.51.0
#3 lore raw

Re: [PATCH v2] PCI: pciehp: Add PLX 8600/8700 quirk for missing Command Completed events

Sashiko has reviewed this patch and found no issues. It looks great!
Quoted 17 lines

All PLX PEX 8600- and 8700-series data books say the Command Completed bit is set only after the Hot Plug Controller completes a command that changes the Attention Indicator Control, Power Indicator Control, Power Controller Control, or Electromechanical Interlock Control fields. It is not set after writes that only change the Presence Detect Changed Enable or Command Completed Interrupt Enable bits.

Consequently, pciehp waits for Command Completed after changing these notification Enable bits and logs a timeout, for example:

pcieport 0000:90:02.0: pciehp: Timeout on hotplug command 0x07c0 (issued 2032 msec ago)

Like the controllers already handled by quirk_cmd_compl(), these PLX switches report completion only when the same four Control fields change and fail to report completion for notification Enable-only writes.

Quoted 6 lines

Add only the PLX PEX 8600- and 8700-series switches on which this fix was tested to quirk_cmd_compl(). This makes pciehp mark Enable-only writes complete immediately while continuing to wait for commands that change Control fields.

Sashiko has reviewed this patch and found no issues. It looks great!

Signature · 1 line
Sashiko AI review · https://sashiko.dev/#/patchset/[email protected]?part=1