PCI: Avoid D3 on PLX PEX 8532/8533/8548 downstream ports
Subsystems (2)
PATCH 1/1 PCI: Avoid D3 on PLX PEX 8532/8533/8548 downstream ports
Runtime PM suspends an idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch to D3hot, but that takes the whole switch down with it: any device behind another port of the same switch then faults with a fatal bus error on its next access, e.g. mptsas probe on a Sun Ultra 45.
This surfaced on sparc64 once commit a5fb3ff63287 ("PCI: Allow PCI bridges to go to D3Hot on all non-x86") let bridges enter D3hot. Keep these downstream ports out of D3 by setting PCI_DEV_FLAGS_NO_D3.
--- drivers/pci/quirks.c | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+)
drivers/pci/quirks.c +18 -0
@@ -2381,6 +2381,24 @@ DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_9050,DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2000 , quirk_plx_pci9050);DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2600 , quirk_plx_pci9050); +/* +* An idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch +* autosuspends into D3hot, and that takes the whole switch down with +* it -- any device behind another port of the same switch then sees a +* fatal, non-recoverable bus fault on its next access. Keep these +* ports out of D3 entirely. +*/ +static void quirk_plx_pex_no_d3 (struct pci_dev *dev) +{ +if (pci_pcie_type (dev) ==PCI_EXP_TYPE_DOWNSTREAM ) { + dev->dev_flags |=PCI_DEV_FLAGS_NO_D3 ; +pci_info (dev,"avoiding D3 on this downstream port\n" ); + } +} +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8532 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8533 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8548 , quirk_plx_pex_no_d3); +static void quirk_netmos (struct pci_dev *dev) {unsigned int num_parallel = (dev->subsystem_device &0xf0 ) >>4 ;
base-commit: fe2ec83746e501645709761605c2464a44fd2929
Signature · 1 line
2.47.3
[email protected]
AI reviewSashiko has reviewed this patch and found no issues. It looks great!
Quoted 6 lines
Runtime PM suspends an idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch to D3hot, but that takes the whole switch down with it: any device behind another port of the same switch then faults with a fatal bus error on its next access, e.g. mptsas probe on a Sun Ultra 45.
Quoted 7 lines
This surfaced on sparc64 once commit
a5fb3ff63287("PCI: Allow PCI bridges to go to D3Hot on all non-x86") let bridges enter D3hot. Keep these downstream ports out of D3 by settingPCI_DEV_FLAGS_NO_D3.Fixes a5fb3ff63287 ("PCI: Allow PCI bridges to go to D3Hot on all non-x86")Signed-off-by Imre Kaloz <[email protected]>
Sashiko has reviewed this patch and found no issues. It looks great!
Signature · 1 line
Sashiko AI review · https://sashiko.dev/#/patchset/[email protected]?part=1
Hi Imre,
Tested this on a Sun Ultra 45 with PLX PEX8532 downstream ports and an LSI SAS1064 controller.
Without the patch, enabling CONFIG_PCIEPORTBUS reproducibly causes a Cheetah bus-error panic when mptbase probes the controller. The kernel boots with pcie_port_pm=off.
With this patch, the same kernel and config boot successfully without pcie_port_pm=off or pcie_ports=compat. The quirk is applied to all five PEX8532 downstream ports, the LSISAS1064 initializes, and the modular mptsas/ext4 setup boots through the initramfs normally.
[+cc several Broadcom folks, help with possible switch erratum]
Quoted 9 lines · Imre Kaloz
Runtime PM suspends an idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch to D3hot, but that takes the whole switch down with it: any device behind another port of the same switch then faults with a fatal bus error on its next access, e.g. mptsas probe on a Sun Ultra 45.
This surfaced on sparc64 once commit
a5fb3ff63287("PCI: Allow PCI bridges to go to D3Hot on all non-x86") let bridges enter D3hot. Keep these downstream ports out of D3 by settingPCI_DEV_FLAGS_NO_D3.
I don't really have any objection to this, but I am concerned that this quirk only applies to a few specific devices, but
https://admin.pci-ids.ucw.cz/read/PC/10b5 shows a TON of similar-looking switches that I assume have the same behavior, so this may be just the tip of the iceberg.
Quoted 41 lines
Fixes a5fb3ff63287 ("PCI: Allow PCI bridges to go to D3Hot on all non-x86")Signed-off-by Imre Kaloz <[email protected]>--- drivers/pci/quirks.c | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+)drivers/pci/quirks.c +18
-0@@ -2381,6 +2381,24 @@ DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_9050,DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2000 , quirk_plx_pci9050);DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2600 , quirk_plx_pci9050); +/* +* An idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch +* autosuspends into D3hot, and that takes the whole switch down with +* it -- any device behind another port of the same switch then sees a +* fatal, non-recoverable bus fault on its next access. Keep these +* ports out of D3 entirely. +*/ +static void quirk_plx_pex_no_d3 (struct pci_dev *dev) +{ +if (pci_pcie_type (dev) ==PCI_EXP_TYPE_DOWNSTREAM ) { + dev->dev_flags |=PCI_DEV_FLAGS_NO_D3 ; +pci_info (dev,"avoiding D3 on this downstream port\n" ); + } +} +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8532 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8533 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8548 , quirk_plx_pex_no_d3); +static void quirk_netmos (struct pci_dev *dev) {unsigned int num_parallel = (dev->subsystem_device &0xf0 ) >>4 ;base-commit:
fe2ec83746e501645709761605c2464a44fd2929Signature · 1 line
2.47.3
Bjorn Helgaas
AppliedQuoted 6 lines · Imre Kaloz
Runtime PM suspends an idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch to D3hot, but that takes the whole switch down with it: any device behind another port of the same switch then faults with a fatal bus error on its next access, e.g. mptsas probe on a Sun Ultra 45.
Quoted 7 lines
This surfaced on sparc64 once commit
a5fb3ff63287("PCI: Allow PCI bridges to go to D3Hot on all non-x86") let bridges enter D3hot. Keep these downstream ports out of D3 by settingPCI_DEV_FLAGS_NO_D3.Fixes a5fb3ff63287 ("PCI: Allow PCI bridges to go to D3Hot on all non-x86")Signed-off-by Imre Kaloz <[email protected]>
Applied to pci/pm for v7.4, thanks!
Quoted 38 lines
--- drivers/pci/quirks.c | 18 ++++++++++++++++++ 1 file changed, 18 insertions(+)drivers/pci/quirks.c +18
-0@@ -2381,6 +2381,24 @@ DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_9050,DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2000 , quirk_plx_pci9050);DECLARE_PCI_FIXUP_HEADER (0x1402 ,0x2600 , quirk_plx_pci9050); +/* +* An idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch +* autosuspends into D3hot, and that takes the whole switch down with +* it -- any device behind another port of the same switch then sees a +* fatal, non-recoverable bus fault on its next access. Keep these +* ports out of D3 entirely. +*/ +static void quirk_plx_pex_no_d3 (struct pci_dev *dev) +{ +if (pci_pcie_type (dev) ==PCI_EXP_TYPE_DOWNSTREAM ) { + dev->dev_flags |=PCI_DEV_FLAGS_NO_D3 ; +pci_info (dev,"avoiding D3 on this downstream port\n" ); + } +} +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8532 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8533 , quirk_plx_pex_no_d3); +DECLARE_PCI_FIXUP_FINAL (PCI_VENDOR_ID_PLX ,0x8548 , quirk_plx_pex_no_d3); +static void quirk_netmos (struct pci_dev *dev) {unsigned int num_parallel = (dev->subsystem_device &0xf0 ) >>4 ;base-commit:
fe2ec83746e501645709761605c2464a44fd2929Signature · 1 line
2.47.3
Quoted 13 lines · Bjorn Helgaas
[+cc several Broadcom folks, help with possible switch erratum]
Quoted 9 lines · Imre Kaloz
Runtime PM suspends an idle downstream port of a PLX/Broadcom PEX 8532/8533/8548 switch to D3hot, but that takes the whole switch down with it: any device behind another port of the same switch then faults with a fatal bus error on its next access, e.g. mptsas probe on a Sun Ultra 45.
This surfaced on sparc64 once commit
a5fb3ff63287("PCI: Allow PCI bridges to go to D3Hot on all non-x86") let bridges enter D3hot. Keep these downstream ports out of D3 by settingPCI_DEV_FLAGS_NO_D3.
Quoted 9 lines
I don't really have any objection to this, but I am concerned that this quirk only applies to a few specific devices, but
https://admin.pci-ids.ucw.cz/read/PC/10b5 shows a TON of similar-looking switches that I assume have the same behavior, so this may be just the tip of the iceberg.Quoted 3 lines
Fixes a5fb3ff63287 ("PCI: Allow PCI bridges to go to D3Hot on all non-x86")Signed-off-by Imre Kaloz <[email protected]>
Our internal portal does not have any document for the 8532/8533/8548 so unfortunately I cannot help here with identifying an errata document.
Signature · 1 line
Florian