PATCH Superseded Joshua Machauer 4 participants 5 messages Nov 19 – Nov 23 PCI

v1 of 2 Superseded Latest is v2 →

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 PCI: Skip the CXL state update for a VF

set_pcie_cxl() runs for every device that is added. It first updates the CXL state of the upstream bridge, which walks that bridge's extended capabilities and recurses up to the root port. It then walks the device's own extended capabilities for the Flex Bus Port DVSEC.

For a VF neither walk can change anything. A CXL device exposes its Flex Bus Port DVSEC through Function 0 (CXL 4.0, section 8.1.8), so the search in a VF finds nothing and the VF's is_cxl stays false. pci_upstream_bridge() resolves a VF through its PF, so the bridge is the one that was already updated when the PF was added.

Enabling SR-IOV adds the VFs one after another, and each add repeats both walks against the same bridges.

On an NVIDIA Vera system, enabling 256 VFs on a PF whose upstream bridge has 18 extended capabilities takes 296 ms instead of 402 ms. Enabling 32 VFs on a Rubin GPU takes 218 ms instead of 235 ms. The times are for the write to sriov_numvfs, with the PF bound to pci-pf-stub and VF driver autoprobe disabled, so no VF driver probes.

Return early for a VF. Every device keeps the is_cxl value it gets today.

---
 drivers/pci/probe.c | 8 ++++++++
 1 file changed, 8 insertions(+)
drivers/pci/probe.c +8 -0
index 9a178e0e5f7f..34acebd1c706 100644
@@ -1717,6 +1717,14 @@ static void set_pcie_cxl(struct pci_dev *dev)
 	if (!pci_is_pcie(dev))
 		return;
 
+	/*
+	 * A CXL device exposes its Flex Bus Port DVSEC through Function 0,
+	 * so a VF has none. Its upstream bridge is the PF's, which was
+	 * updated when the PF was added.
+	 */
+	if (dev->is_virtfn)
+		return;
+
 	/*
 	 * Update parent's CXL state because alternate protocol training
 	 * may have changed
Signature · 1 line
2.47.3
#1 lore raw
Sashiko has reviewed this patch and found no issues.
Quoted 20 lines

set_pcie_cxl() runs for every device that is added. It first updates the CXL state of the upstream bridge, which walks that bridge's extended capabilities and recurses up to the root port. It then walks the device's own extended capabilities for the Flex Bus Port DVSEC.

For a VF neither walk can change anything. A CXL device exposes its Flex Bus Port DVSEC through Function 0 (CXL 4.0, section 8.1.8), so the search in a VF finds nothing and the VF's is_cxl stays false. pci_upstream_bridge() resolves a VF through its PF, so the bridge is the one that was already updated when the PF was added.

Enabling SR-IOV adds the VFs one after another, and each add repeats both walks against the same bridges.

On an NVIDIA Vera system, enabling 256 VFs on a PF whose upstream bridge has 18 extended capabilities takes 296 ms instead of 402 ms. Enabling 32 VFs on a Rubin GPU takes 218 ms instead of 235 ms. The times are for the write to sriov_numvfs, with the PF bound to pci-pf-stub and VF driver autoprobe disabled, so no VF driver probes.

Quoted 4 lines

Return early for a VF. Every device keeps the is_cxl value it gets today.

Sashiko has reviewed this patch and found no issues.

Signature · 1 line
Sashiko AI review · https://sashiko.dev/#/patchset/[email protected]?part=1
Reviewed-by on v1 1/1
#2 lore raw
In reply to Joshua Machauer
Quoted 20 lines · Joshua Machauer

set_pcie_cxl() runs for every device that is added. It first updates the CXL state of the upstream bridge, which walks that bridge's extended capabilities and recurses up to the root port. It then walks the device's own extended capabilities for the Flex Bus Port DVSEC.

For a VF neither walk can change anything. A CXL device exposes its Flex Bus Port DVSEC through Function 0 (CXL 4.0, section 8.1.8), so the search in a VF finds nothing and the VF's is_cxl stays false. pci_upstream_bridge() resolves a VF through its PF, so the bridge is the one that was already updated when the PF was added.

Enabling SR-IOV adds the VFs one after another, and each add repeats both walks against the same bridges.

On an NVIDIA Vera system, enabling 256 VFs on a PF whose upstream bridge has 18 extended capabilities takes 296 ms instead of 402 ms. Enabling 32 VFs on a Rubin GPU takes 218 ms instead of 235 ms. The times are for the write to sriov_numvfs, with the PF bound to pci-pf-stub and VF driver autoprobe disabled, so no VF driver probes.

Quoted 4 lines

Return early for a VF. Every device keeps the is_cxl value it gets today.

commit log a bit wordy, otherwise LGTM

Quoted 23 lines
---
 drivers/pci/probe.c | 8 ++++++++
 1 file changed, 8 insertions(+)
drivers/pci/probe.c +8 -0
index 9a178e0e5f7f..34acebd1c706 100644
@@ -1717,6 +1717,14 @@ static void set_pcie_cxl(struct pci_dev *dev)
 	if (!pci_is_pcie(dev))
 		return;
 
+	/*
+	 * A CXL device exposes its Flex Bus Port DVSEC through Function 0,
+	 * so a VF has none. Its upstream bridge is the PF's, which was
+	 * updated when the PF was added.
+	 */
+	if (dev->is_virtfn)
+		return;
+
 	/*
 	 * Update parent's CXL state because alternate protocol training
 	 * may have changed
#3 lore raw
In reply to Joshua Machauer
Quoted 14 lines · Joshua Machauer

set_pcie_cxl() runs for every device that is added. It first updates the CXL state of the upstream bridge, which walks that bridge's extended capabilities and recurses up to the root port. It then walks the device's own extended capabilities for the Flex Bus Port DVSEC.

For a VF neither walk can change anything. A CXL device exposes its Flex Bus Port DVSEC through Function 0 (CXL 4.0, section 8.1.8), so the search in a VF finds nothing and the VF's is_cxl stays false. pci_upstream_bridge() resolves a VF through its PF, so the bridge is the one that was already updated when the PF was added.

Enabling SR-IOV adds the VFs one after another, and each add repeats both walks against the same bridges.

Quoted 9 lines

On an NVIDIA Vera system, enabling 256 VFs on a PF whose upstream bridge has 18 extended capabilities takes 296 ms instead of 402 ms. Enabling 32 VFs on a Rubin GPU takes 218 ms instead of 235 ms. The times are for the write to sriov_numvfs, with the PF bound to pci-pf-stub and VF driver autoprobe disabled, so no VF driver probes.

Return early for a VF. Every device keeps the is_cxl value it gets today.

Hi Joshua,

The fix looks correct to me.

One nit on the sentence above, before this patch, each VF add also re-read the Flex Bus Port Status of every bridge above the PF.
That refresh is now gone. I don't think anything depends on it, but it is a behavior change, might be worth to mention it.

Quoted 11 lines
---
 drivers/pci/probe.c | 8 ++++++++
 1 file changed, 8 insertions(+)
drivers/pci/probe.c +0 -0
index 9a178e0e5f7f..34acebd1c706 100644
@@ -1717,6 +1717,14 @@ static void set_pcie_cxl(struct pci_dev *dev)
 	if (!pci_is_pcie(dev))

drivers/pci/probe.c static void set_pcie_cxl(struct pci_dev *dev) · line 1727

Quoted 10 lines
drivers/pci/probe.c +8 -0
 		return;
 
+	/*
+	 * A CXL device exposes its Flex Bus Port DVSEC through Function 0,
+	 * so a VF has none. Its upstream bridge is the PF's, which was
+	 * updated when the PF was added.
+	 */
+	if (dev->is_virtfn)
+		return;
+

I would like the spec section to be cited here, CXL r4.0, sec 8.1.8 "PCIe DVSEC for Flex Bus Port"

Quoted 7 lines
drivers/pci/probe.c +0 -0
 	/*
 	 * Update parent's CXL state because alternate protocol training
 	 * may have changed
Signature · 1 line
2.47.3

A wider question, not specifically a request for this patch.
The repeated walks are not specific to VFs. The recursion runs for every PCIe device and goes up to the Root Port, so every function added below a switch walks the extend capabilities of all the bridges above it again.

Is the walk to the RP needed, or would refreshing only the immediate parent would be enough ?
If it's the former case, we can cut more cost for non-VF devices too.

Best regards,
Richard Cheng.

#4 lore raw
Quoted 4 lines · Richard Cheng

One nit on the sentence above, before this patch, each VF add also re-read the Flex Bus Port Status of every bridge above the PF.
That refresh is now gone. I don't think anything depends on it, but it is a behavior change, might be worth to mention it.

[...]

Quoted 2 lines

I would like the spec section to be cited here, CXL r4.0, sec 8.1.8 "PCIe DVSEC for Flex Bus Port"

Thanks. v2 states the dropped refresh and cites the spec section in the comment.

Quoted 3 lines

Is the walk to the RP needed, or would refreshing only the immediate parent would be enough ?
If it's the former case, we can cut more cost for non-VF devices too.

Refreshing the immediate parent looks enough to me. A device is only visible once the link to its parent's downstream port has trained, and the links further up were already read when the device directly below each of them was added. The link speed in pci_bus is handled that way
too: it is read when the bus is added and updated on link events (retrain, bandwidth notification, hotplug), not on every child add.

I don't have a system with a CXL switch to test that change on, so I have kept v2 to the VF case.

Joshua