Hi Lei YU,

There is some question about avsbus-control and vrm-control on the Romulus. There are no public documentation for the IR35221 chips, which are used in the Romulus. Could anyone explain what avsbus-control and vrm-control i2c command sequences do or give register description for the IR35221, please?

Regards,

Alexander Soldatov.

#1 lore raw

Hi Alexander,

The related controls to IR35221 are referenced from meta-witherspoon and Romulus schematic.
If you need details, possibly contact Nick ([email protected]) who is the chief engineer of Romulus.

Thanks!

Quoted 10 lines · Alexander Soldatov

Hi Lei YU,

There is some question about avsbus-control and vrm-control on the Romulus. There are no public documentation for the IR35221 chips, which are used in the Romulus. Could anyone explain what avsbus-control and vrm-control i2c command sequences do or give register description for the IR35221, please?

Regards,

Alexander Soldatov.

#2 lore raw
In reply to Alexander Soldatov
Quoted 5 lines · Alexander Soldatov

Hi Lei YU,

There is some question about avsbus-control and vrm-control on the Romulus. There are no public documentation for the IR35221 chips, which are used in the Romulus. Could anyone explain what avsbus-control and vrm-control i2c command sequences do or give register description for the IR35221, please?

There's an upstream driver for this part that may help:

drivers/hwmon/pmbus/ir35221.c

There was a plan to replace (some?) of the scripts you reference with the kernel driver. However these parts are powered by the same net as the CPU, so when the host is powered off the hwmon driver cannot be used. It would be good to come up with a kernel based solution here.

Cheers,

Joel