Remote Loopback
Hi,
(Please ignore if received once under subject Test Mode)
I was able to conduct the local loopback test on DBT-120(so CSR).........so i can
state that anycom usb-120 does not support the HCI_Write_Loopback_Mode command.
I tried the remote loopback test as per Peter's instructions and the spec ....but it doesn't seem to work.
I first have set my remote device(B) for Remote_loopback (Becoz estabhlising a connection and then setting for remote loopback doesn't work).
I then use the Write command and verify that it is set using the Read command. I now establish a HCI connection from my local device(A) to B. The connection is established. From A, i send a command packet to B, expecting a loopback event, instead i get a regular reply for the command packet (as though the remote device is not set for loopback). What packets should i send for testing the remote loopback??
"hcitool con" on A shows the connection.
< ACL 00:11:35:00:22:B9 handle 41 state 1 lm MASTER
"hcitool con" on B doesn't show anything.
I also tried the switch role for B to be the master....but it remains as the slave.
Hope you can help me out. Anything I have missed out??
Thanks,
regards,
manjunath
-------------------------------------------------------
SF email is sponsored by - The IT Product Guide
Read honest & candid reviews on hundreds of IT Products from real users. Discover which products truly live up to the hype. Start reading now.
http://productguide.itmanagersjournal.com/
_______________________________________________
Bluez-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bluez-users