Skip to contentSkip to conversation

Switch SensorCollection to show all sensors as new power/thermal schemas implemented

DISCUSSION Gunnar Mills 2 participants 4 messages Jan 11, 2021 – Feb 16, 2021

lore
Share & tools
lore
#0 lore raw

Similar discussion has been on the mailing list before: https://lists.ozlabs.org/pipermail/openbmc/2020-October/023568.html

The new PowerSubsystem/ThermalSubsystem Redfish schemas can coexist with the old Power/Thermal schemas. I suspect we will have both the new and old for some time. As we implement the new PowerSubsystem/ThermalSubsystem is it okay to switch the behavior of the sensor collection from "show sensors that are not covered elsewhere in the model" to "show all sensors" as the new PowerSubsystem/ThermalSubsystem schemas call for?

I reposted in https://redfishforum.com/thread/190/sensorcollection-contain-all-sensors-chassis, unless I am missing something I believe Redfish's guidance will be "move to a SensorCollection that shows all the sensors". If indeed that is their guidance, is everyone okay as we implement the new PowerSubsystem/ThermalSubsystem in bmcweb, we move sensor collection to show all sensors? Things like webui-vue will have to be updated (not sure anything breaks for webui-vue just would have duplicate sensors).

Thanks,
Gunnar

#1 lore raw
Quoted 5 lines · Gunnar Mills

Similar discussion has been on the mailing list before: https://lists.ozlabs.org/pipermail/openbmc/2020-October/023568.html

The new PowerSubsystem/ThermalSubsystem Redfish schemas can coexist with the old Power/Thermal schemas. I suspect we will have both the new and old for some time. As we implement the new PowerSubsystem/ThermalSubsystem is it okay to switch the behavior of the sensor collection from "show sensors that are not covered elsewhere in the model" to "show all sensors" as the new PowerSubsystem/ThermalSubsystem schemas call for?

I reposted in https://redfishforum.com/thread/190/sensorcollection-contain-all-sensors-chassis, unless I am missing something I believe Redfish's guidance will be "move to a SensorCollection that shows all the sensors". If indeed that is their guidance, is everyone okay as we implement the new PowerSubsystem/ThermalSubsystem in bmcweb, we move sensor collection to show all sensors? Things like webui-vue will have to be updated (not sure anything breaks for webui-vue just would have duplicate sensors).

Redfish's reply was "My statement from 18 months ago is no longer our recommendation. That was before we proposed to re-factor the Power and Thermal schemas to use the Sensor model. And that continues to be our direction. So in that light, we want everything that counts as a "sensor" to be part of the Sensor collection so that generic monitoring software can be built to harvest sensor data across the Redfish model.

Even if an implementation hasn't decided to adopt the (still a work-in-progress) PowerSubystem and ThermalSubsystem models, the underlying temperature and fan sensors can be rendered as Redfish Sensor resources as a good middle ground (and a step in the right direction for future work).".

Based on that reply, I propose we move Redfish SensorCollection to show all sensors. Let me know if anyone objects.

Thanks,
Gunnar

#2 lore raw

Hi Gunnar,

Quoted 4 lines · Gunnar Mills

On 1/11/2021 11:19 AM, Gunnar Mills wrote:
Based on that reply, I propose we move Redfish SensorCollection to show all sensors. Let me know if anyone objects.

Where would the sensor collection be rooted at? /redfish/v1/chassis/{ID}/sensors? If so, would this also contain sensors accessible to the system software (some CPU/DIMM sensors for eg)?

Thanks,
Deepak

#3 lore raw
Quoted 3 lines · Deepak Kodihalli

Where would the sensor collection be rooted at?
/redfish/v1/chassis/{ID}/sensors?

Late reply. Yes. Sensors are associated to a chassis via an association.
https://github.com/openbmc/docs/blob/919a7b6816a5f16aa72d298e81e0756d95d5031e/architecture/sensor-architecture.md#association-type-1-linking-a-chassis-to-all-sensors-within-the-chassis

https://gerrit.openbmc-project.xyz/c/openbmc/bmcweb/+/40169 is the code for moving bmcweb to all sensors in the sensor collection.

If so, would this also contain

Quoted 2 lines

sensors accessible to the system software (some CPU/DIMM sensors for eg)?

Yes, it could. There is nothing in the Redfish spec that prevents that. The definition of what a sensor is in Redfish is very broad. If you need additional "ReadingTypes", I'm sure Redfish would be willing to add with a use case.

https://redfish.dmtf.org/schemas/v1/Sensor.v1_2_0.json

Hope this helps,
Gunnar