regulator: BD71837: possible regression

DISCUSSION Vaittinen, Matti 2 participants 2 messages May 14, 2019 1 message not in the archive

lore
Share & tools
lore

A message that is not in the archive (sent off-list or not yet received): [email protected]

#1 lore raw

Hello Angus,

I'll add the linux list and Mark to CC as this sounds like a regression which may impact to other regulator drivers too. Mark, please let me know if you don't feel adding you to discussions like this are appropriate so I don't do it in the future.

Quoted 24 lines · Angus Ainslie

Hi Matti,

I've been doing some integration with our feature branches on linux- next
(next-20190510) and I hit a snag as soon as I enable the BD71837.

There's a couple of weird things I'm seeing

[    0.907025] bd718xx-pmic bd718xx-pmic.2.auto: no default pinctrl 
state
[    0.907651] bd718xx-pmic bd718xx-pmic.2.auto: Unlocked lock
register 
0x2f
[    0.932483] rohm-bd718x7 0-004b: Looking up buck6-supply from
device 
tree
[    0.932499] rohm-bd718x7 0-004b: Looking up buck6-supply property
in 
node /soc@0/bus@30800000/i2c@30a20000/pmic@4b fa
iled
[    0.937861] rohm-bd718x7 0-004b: Looking up buck7-supply from
device 
tree
[    0.937877] rohm-bd718x7 0-004b: Looking up buck7-supply property
Quoted 3 lines

in
node /soc@0/bus@30800000/i2c@30a20000/pmic@4b fa
iled

Does this mean we have a regression in linux-next? I guess you have not seen these issues in older kernels?

Quoted 1 line

What should buck6/7 supply be set to ?

The buck6 and buck7 are not supplied by any other regulators. What is special about buck6 and buck7 is that they are supplying LDOs 5 and 6. So I assume the problem emerges when LDOs are trying to find their suppliers. (I am not sure if supplier is correct word - but what I mean is that bucks 6 and 7 are kind of parents for LDOs). This is reflected in regulator_desc for LDOs. (The supply_name field is set).

I am not sure but perhaps the regulator core is changed so that this parent/child relation must be modelled using <foo>-supply properties in device-tree. Are you able to bisect the change which breaks this? There may be other regulator drivers doing the same as bd718x7 is (which means trusiting to setting the supply_name in desc to be enough - and without deeper understanding I'd say it should be enough).

If this change is intentional and buck6-supply and buck7-supply are bow required also in DT, then we should reflect this fact also in bindings doc for BD71837 and BD71847.

Quoted 5 lines

The rtc also seems to have lost it's mind

[  497.363621] rtc rtc0: Timeout waiting for LPSRT Counter to change

Am I missing linking the bd71837 clock to the rtc somehow ?

I don't think there is any SW actions required. The 30.72K clock can be controlled using clk-bd718x7 driver - but I don't think there has been changes there and this drivers should not touch the clk gate unless asked by some user. Still, if the bucks6/7 get disabled for some reason (or if LDOs are enabled before these bucks are enabled) - then, without the correct parent child relation the LDOs can't get enabled - and voltage monitoring may kick-in. Yet, assuming the SoC is powered by bd71837 this should probably lead to reset-loop and not just to clock errors...

I would definitely start looking at the changes in how suppliers are looked up and maybe also tried setting the buck6-supply and buck7- supply properties with phandles to buck6 and buck7 nodes. I can also try checking the core if you don't have the possibility to do bisecting
- but I am not able to do it right now. It may be I can check this only at next week.

Quoted 2 lines

And finally the reset is hanging again even with
"rohm,reset-snvs-powered".

This could well be due to the missing parent/child relation between bucks and LDOs.

Quoted 5 lines

Pointers would be appreciated.

Thanks
Angus

Br,
Matti Vaittinen

#2 lore raw
Quoted 6 lines · Matti

I am not sure but perhaps the regulator core is changed so that this parent/child relation must be modelled using <foo>-supply properties in device-tree. Are you able to bisect the change which breaks this? There may be other regulator drivers doing the same as bd718x7 is (which means trusiting to setting the supply_name in desc to be enough - and without deeper understanding I'd say it should be enough).

The framework will look for the parent regulator and warn if it can't find it but it should still instantiate it if the mapping is a hard failure (as opposed to a probe deferral).

Quoted 3 lines

If this change is intentional and buck6-supply and buck7-supply are bow required also in DT, then we should reflect this fact also in bindings doc for BD71837 and BD71847.

It is always and has always been best practice to wire up the regulators as completely as possible; this is less error prone and gives you more ability to take advantage of framework improvements.