Can't read bytes from x16 device
Hi,
I have an Intel 28F640J5 part in x16 mode. It appears I can't read bytes which are odd aligned. After reading one odd aligned byte all reads fail.
I'm using the 1_by_16 routines in cfi_cmdset_0001.c
David Vrabel.
To unsubscribe, send "unsubscribe mtd" to [email protected]
Quoted 3 lines · David Vrabel
I have an Intel 28F640J5 part in x16 mode. It appears I can't read bytes which are odd aligned. After reading one odd aligned byte all reads fail.
Reading the specs for this chip indicates that the high byte is not used for command or status information. So I changed do_read_1_by_16_onechip() to align commands and status reads on word boundaries.
David Vrabel.
To unsubscribe, send "unsubscribe mtd" to [email protected]