Skip to contentSkip to conversation

Data CRC failed on node at ...

DISCUSSION Steven Scholz 2 participants 2 messages Jan 30, 2003 Memory technology devices (MTD)

lore
Share & tools
lore
#0 lore raw

Hi there,

while booting my system I get a

"jffs2_scan_inode_node(): Data CRC failed on node at 0x003a14e0: Read 0xdbd307bb, calculated 0x5a8c4838"

now. Maybe since I interrupted an ftp transfer.

What can I do now?

Is there something like a repair tool?
Or can I at least find out which file is corrupted?

Thanks,

Steven

#1 lore raw
Quoted 1 line · [email protected] said:

What can I do now?

Ignore it.

Quoted 1 line

Is there something like a repair tool?

Not at the moment, no.

Quoted 1 line

Or can I at least find out which file is corrupted?

Nothing's corrupted. It's probably because the machine was powered off or rebooted while it was busy garbage-collecting. As it writes out new replacement nodes before the old ones are marked obsolete, if you interrupt it, it means that the original node will have remained intact on the flash -- only the new node which was _going_ to replace it is broken, and that's part of what the CRC check is there for.

It'll go away in time when the block in which the offending node resides is garbage collected.

--
dwmw2