nguid for nvme over fabrics

DISCUSSION Narasimhan V 3 participants 5 messages Mar 20, 2018 – Mar 30, 2018 NVMe

lore
Share & tools
lore
#0 lore raw

Hi,

I am trying nvme over fabrics, and found this: nguid is set to 0s by default for all devices.

So, nguid can be same (0s in this case) for multiple devices. Is this valid ?
Also, same nguid for multiple devices could be set, by the above scenario.
No errors/warnings from either the nvme initiator/target.

From spec, I see this:
Namespace Globally Unique Identifier (NGUID): This field contains a 128-bit value that is
globally unique and assigned to the namespace when the namespace is created. This field
remains fixed throughout the life of the namespace and is preserved across namespace and
controller operations (e.g., controller reset, namespace format, etc.).

Signature · 2 lines
Regards
Narasimhan V
maintainer
#1 lore raw
Quoted 11 lines

Hi,

I am trying nvme over fabrics, and found this: nguid is set to 0s by default for all devices.

So, nguid can be same (0s in this case) for multiple devices. Is this valid ?
Also, same nguid for multiple devices could be set, by the above scenario. No errors/warnings from either the nvme initiator/target.

Quoted 8 lines

From spec, I see this:
Namespace Globally Unique Identifier (NGUID): This field contains a 128-bit value that is
globally? unique and assigned to? the? namespace? when? the? namespace is? created.? This? field
remains fixed throughout the life of the namespace and is preserved across namespace and
controller operations (e.g., controller reset,? namespace format, etc.).

We generate a UUID (which can be overwritten by the user)

#2 lore raw
Quoted 21 lines · Sagi Grimberg
Quoted 11 lines

Hi,

I am trying nvme over fabrics, and found this: nguid is set to 0s by default for all devices.

So, nguid can be same (0s in this case) for multiple devices. Is this valid ?
Also, same nguid for multiple devices could be set, by the above scenario.
No errors/warnings from either the nvme initiator/target.

Quoted 9 lines

From spec, I see this:
Namespace Globally Unique Identifier (NGUID): This field contains a 128-bit value that is
globally? unique and assigned to? the? namespace? when? the? namespace is? created.? This? field
remains fixed throughout the life of the namespace and is preserved across namespace and
controller operations (e.g., controller reset,? namespace format, etc.).

Quoted 1 line

We generate a UUID (which can be overwritten by the user)

Shouldn't it be unique ?
I have instances where for NVMef, multiple devices can have same nguids. Which component should be responsible to generate nguid in NVMef ?

Signature · 2 lines
Regards
Narasimhan V
#3 lore raw
Quoted 3 lines · Narasimhan V

Shouldn't it be unique ?
I have instances where for NVMef, multiple devices can have same nguids. Which component should be responsible to generate nguid in NVMef ?

You must only usea nguid if you have a ieee id, and then it is your responsibility to hand out ids based on that.

Which means that you generally should not set a nguid unless you are building an appliance and really know what you are doing.

#4 lore raw
Quoted 8 lines · Christoph Hellwig
Quoted 4 lines · Narasimhan V

Shouldn't it be unique ?
I have instances where for NVMef, multiple devices can have same nguids.
Which component should be responsible to generate nguid in NVMef ?

You must only usea nguid if you have a ieee id, and then it is your responsibility to hand out ids based on that.

Thnaks Chris,
I get it now.

Quoted 4 lines

Which means that you generally should not set a nguid unless you are building an appliance and really know what you are doing.

For my confirmation, if we are setting duplicate nguids, it is user's responsibility, and system does not give any warning / error ?

Quoted 4 lines