Field unit is not handled correctly
Hi,
I have a problem that field unit is not handled correctly. For example, when I try the following method, the Local0 have a value '0x3FFFFF', while my expectation is '0x3FFF'.
/*
* Note: Region ABCD is filled with 0xF
*/
OperationRegion (ABCD, SystemMemory, 0x100000, 0x1000) Field (ABCD, AnyAcc, NoLock, WriteAsZeros) {
AAAA, 14, BBBB, 1 }
Method (TEST, 0, NotSerialized) {
Store (AAAA, Local0)
Store (Local0, Debug)
}
I don't know the implementation of ACPI core subsystem very much, but I suspect that there are something wrong in acpi_ex_extract_from_field().
Does anyone have the information about that?
Thanks,
Kenji Kaneshige
-------------------------------------------------------