FEC and TSEC in MPC8540...
Hi All,
I am trying to use both TSEC and FEC interface in MPC8540 in U-Boot . Is it possible for me to use both the interface in U-Boot and ping from outside thro' these 2 interfaces ?. Right now i could use only one interface i.e TSEC ?. Can anyone shed some light on this.
Thanks and Regards
sivam
You cannot ping the bootloader, as far as I know. You can ping from u-boot, but not the other way around. Also, only one interface (TSEC1, TSEC2, or FEC) will be active at any one time, and only while u-boot is executing a network command.
Quoted 20 lines · sivam
Hi All,
I am trying to use both TSEC and FEC interface in MPC8540 in U-Boot . Is it possible for me to use both the interface in U-Boot and ping from outside thro' these 2 interfaces ?. Right now i could use only one interface i.e TSEC ?. Can anyone shed some light on this.
Thanks and Regards
sivam-------------------------------------------------------