Sigh,

I'm having what might be xfs/nfsd conflicts and thought I'd reboot into an old 2.6.6 kernel which used to be stable.

Of course it spotted the fd partitions and tried to start the array.
It failed (the old kernel didn't have a driver for the new controller so some devices were missing)

However when I came back to 2.6.9 I get the rather conflicting status shown below.

It already mounted (xfs) but I unmounted quite quickly. Can this do any harm?

Should I leave it to complete?
Can I safely remount?

My worry is that the kernel and mdadm think all the devices are 'up' and so may write to them and upset the resync (I suspect it thinks /dev/sdf1 is dirty since that wasn't there under 2.6.6)

cu:~# mdadm --detail /dev/md0
/dev/md0:
       Version : 00.90.01
 Creation Time : Sun Nov 21 21:36:49 2004
    Raid Level : raid5
    Array Size : 1225543680 (1168.77 GiB 1254.96 GB)
   Device Size : 245108736 (233.75 GiB 250.99 GB)
  Raid Devices : 6
 Total Devices : 7
Preferred Minor : 0
   Persistence : Superblock is persistent

Update Time : Thu Nov 25 12:51:46 2004
State : dirty, resyncing
Active Devices : 6
Working Devices : 7
Failed Devices : 0
Spare Devices : 1

Layout : left-symmetric
Chunk Size : 4096K

Rebuild Status : 0% complete

          UUID : 44e121b0:6e3422b0:4d67f451:51df5ae0
        Events : 0.35500

Number Major Minor RaidDevice State

      0       8        1        0      active sync   /dev/sda1
      1       8       17        1      active sync   /dev/sdb1
      2       8       33        2      active sync   /dev/sdc1
      3       8       49        3      active sync   /dev/sdd1
      4       3       65        4      active sync   /dev/hdb1
      5       8       81        5      active sync   /dev/sdf1

6 8 65 - spare /dev/sde1
cu:~#

cu:~# cat /proc/mdstat
Personalities : [linear] [raid0] [raid1] [raid5] [raid6]
md0 : active raid5 sdf1[5] sde1[6] sdd1[3] sdc1[2] sdb1[1] sda1[0] hdb1[4]
     1225543680 blocks level 5, 4096k chunk, algorithm 2 [6/6] [UUUUUU]
     [>....................]  resync =  0.3% (905600/245108736) 
finish=304.3min speed=13369K/sec
unused devices: <none>
#1 lore raw

If your only concern is the re-sync, then no problem. An array is usable while it is re-syncing.

However, I don't know why it is re-syncing. Maybe the failed attempt to start the array is at fault. I don't know if this is normal or not.

Guy

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of David Greaves
Sent: Thursday, November 25, 2004 8:05 AM
To: [email protected]
Subject: Help - this doesn't look good...

Sigh,

I'm having what might be xfs/nfsd conflicts and thought I'd reboot into an old 2.6.6 kernel which used to be stable.

Of course it spotted the fd partitions and tried to start the array. It failed (the old kernel didn't have a driver for the new controller so some devices were missing)

However when I came back to 2.6.9 I get the rather conflicting status shown below.

It already mounted (xfs) but I unmounted quite quickly. Can this do any harm?

Should I leave it to complete?
Can I safely remount?

My worry is that the kernel and mdadm think all the devices are 'up' and so may write to them and upset the resync (I suspect it thinks /dev/sdf1 is dirty since that wasn't there under 2.6.6)

cu:~# mdadm --detail /dev/md0
/dev/md0:
        Version : 00.90.01
  Creation Time : Sun Nov 21 21:36:49 2004
     Raid Level : raid5
     Array Size : 1225543680 (1168.77 GiB 1254.96 GB)
    Device Size : 245108736 (233.75 GiB 250.99 GB)
   Raid Devices : 6
  Total Devices : 7
Preferred Minor : 0
    Persistence : Superblock is persistent

Update Time : Thu Nov 25 12:51:46 2004
State : dirty, resyncing
Active Devices : 6
Working Devices : 7
Failed Devices : 0
Spare Devices : 1

Layout : left-symmetric
Chunk Size : 4096K

Rebuild Status : 0% complete

UUID : 44e121b0:6e3422b0:4d67f451:51df5ae0
Events : 0.35500

Number Major Minor RaidDevice State
0 8 1 0 active sync /dev/sda1
1 8 17 1 active sync /dev/sdb1
2 8 33 2 active sync /dev/sdc1
3 8 49 3 active sync /dev/sdd1
4 3 65 4 active sync /dev/hdb1
5 8 81 5 active sync /dev/sdf1

6 8 65 - spare /dev/sde1
cu:~#

cu:~# cat /proc/mdstat
Personalities : [linear] [raid0] [raid1] [raid5] [raid6]
md0 : active raid5 sdf1[5] sde1[6] sdd1[3] sdc1[2] sdb1[1] sda1[0] hdb1[4]
      1225543680 blocks level 5, 4096k chunk, algorithm 2 [6/6] [UUUUUU]
      [>....................]  resync =  0.3% (905600/245108736) 
finish=304.3min speed=13369K/sec
unused devices: <none>

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#2 lore raw

Ta Guy

Normally I'd have no concerns using a resyncing array.
However, on the safe/sorry principle - I didn't mount it since I got the strange conflict from mdadm and indeed mdstat.

As much as anything this is an 'odd behaviour FYI' for Neil

I let it resync and checked the fs - all OK :)

David

Quoted 89 lines · Guy

If your only concern is the re-sync, then no problem. An array is usable while it is re-syncing.

However, I don't know why it is re-syncing. Maybe the failed attempt to start the array is at fault. I don't know if this is normal or not.

Guy

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of David Greaves
Sent: Thursday, November 25, 2004 8:05 AM
To: [email protected]
Subject: Help - this doesn't look good...

Sigh,

I'm having what might be xfs/nfsd conflicts and thought I'd reboot into an old 2.6.6 kernel which used to be stable.

Of course it spotted the fd partitions and tried to start the array.
It failed (the old kernel didn't have a driver for the new controller so some devices were missing)

However when I came back to 2.6.9 I get the rather conflicting status shown below.

It already mounted (xfs) but I unmounted quite quickly. Can this do any harm?

Should I leave it to complete?
Can I safely remount?

My worry is that the kernel and mdadm think all the devices are 'up' and so may write to them and upset the resync (I suspect it thinks /dev/sdf1 is dirty since that wasn't there under 2.6.6)

cu:~# mdadm --detail /dev/md0
/dev/md0:
       Version : 00.90.01
 Creation Time : Sun Nov 21 21:36:49 2004
    Raid Level : raid5
    Array Size : 1225543680 (1168.77 GiB 1254.96 GB)
   Device Size : 245108736 (233.75 GiB 250.99 GB)
  Raid Devices : 6
 Total Devices : 7
Preferred Minor : 0
   Persistence : Superblock is persistent

Update Time : Thu Nov 25 12:51:46 2004
State : dirty, resyncing
Active Devices : 6
Working Devices : 7
Failed Devices : 0
Spare Devices : 1

Layout : left-symmetric
Chunk Size : 4096K

Rebuild Status : 0% complete

          UUID : 44e121b0:6e3422b0:4d67f451:51df5ae0
        Events : 0.35500

Number Major Minor RaidDevice State

      0       8        1        0      active sync   /dev/sda1
      1       8       17        1      active sync   /dev/sdb1
      2       8       33        2      active sync   /dev/sdc1
      3       8       49        3      active sync   /dev/sdd1
      4       3       65        4      active sync   /dev/hdb1
      5       8       81        5      active sync   /dev/sdf1

6 8 65 - spare /dev/sde1
cu:~#

cu:~# cat /proc/mdstat
Personalities : [linear] [raid0] [raid1] [raid5] [raid6]
md0 : active raid5 sdf1[5] sde1[6] sdd1[3] sdc1[2] sdb1[1] sda1[0] hdb1[4]
     1225543680 blocks level 5, 4096k chunk, algorithm 2 [6/6] [UUUUUU]
     [>....................]  resync =  0.3% (905600/245108736) 
finish=304.3min speed=13369K/sec
unused devices: <none>

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

#3 lore raw
In reply to David Greaves
Quoted 11 lines · On Thursday November 25, [email protected] wrote:

Sigh,

I'm having what might be xfs/nfsd conflicts and thought I'd reboot into an old 2.6.6 kernel which used to be stable.

Of course it spotted the fd partitions and tried to start the array. It failed (the old kernel didn't have a driver for the new controller so some devices were missing)

However when I came back to 2.6.9 I get the rather conflicting status shown below.

You might need to explain to me what is "conflicting". It looks to be like the array as 6 working devices and one spare, and that due to an unclean shutdown it is resyncing the 6 working devices.

NeilBrown

#4 lore raw
Quoted 10 lines · Neil Brown
Quoted 7 lines · On Thursday November 25, [email protected] wrote:

Sigh,

I'm having what might be xfs/nfsd conflicts and thought I'd reboot into an old 2.6.6 kernel which used to be stable.

Of course it spotted the fd partitions and tried to start the array.
It failed (the old kernel didn't have a driver for the new controller so some devices were missing)

Quoted 9 lines
Quoted 3 lines

However when I came back to 2.6.9 I get the rather conflicting status shown below.

You might need to explain to me what is "conflicting". It looks to be like the array as 6 working devices and one spare, and that due to an unclean shutdown it is resyncing the 6 working devices.

That's good - I wasn't aware of that mode of operation.
The only time I thought that a resync occurred was if a drive 'failed' and was then hot-added. Seeing a resync and no inactive drives looked inconsistent.

mdadm doesn't indicate which drive is resyncing?
Is there a particular drive at fault or is this more of a sync-check than a resync?

Maybe one for the docs:

The md raid driver will resync in two situations; a resync occurs when a drive is hot-added to a degraded array (usually at first assembly and any time after a drive failure). In this case the array will show the resyncing drive as inactive until the resync completes and it is integrated into the array; a resync can also occur after an unclean shutdown when (presumably) there is an inconsistency in the array devices. In this case all the elements are still active and the resync is just checking to ensure no corruption has occurred.

David