Skip to contentSkip to conversation

interesting failure scenario

DISCUSSION Michael Tokarev 3 participants 3 messages Apr 3, 2005 – Apr 4, 2005 1 message not in the archive MD RAID

lore
Share & tools
lore
#0 lore raw

I just come across an interesting situation, here's the scenario.

0. Have a RAID1 array composed of two components, d1 and d2. The array was running, clean, event counter was 10.
1. d1 failed (eg, hotplug-removed).
2. on d2's superblock we now have event=11, and d1 is marked as failed.
3. the array is running in degraded mode. Some writes happened.
4. stop the array => d2 event counter = 12, clean.
5. hotplug-remove d2, hotplug-add d1.
6. start the array. Now it is started off from d1, which is clean with event count = 10. Since d2 is unaccessible, it is marked as faulty in d1's superblock. The whole operation changes event count to 11.
7. do some writes to the array which is running on degraded mode (writing to d1).
8. Stop the array. Event count on d1 is set to 12.
9. Hotplug-add d2 back.

Now we have an interesting situation. Both superblocks in d1 and d2 are identical, event counts are the same, both are clean. Things wich are different:
utime - on d1 it is "more recent" (provided we haven't touched
the system clock ofcourse)
on d1, d2 is marked as faulty
on d2, d1 is marked as faulty.

Neither of the conditions are checked by mdadm.

So, mdadm just starts a clean RAID1 array composed of two drives with different data on them. And noone noticies this fact (fsck which is reading from one disk goes ok), until some time later when some app reports data corruption (reading from another disk); you go check what's going on, notice there's no data corruption (reading from 1st disk), suspects memory and.. it's quite a long list of possible bad stuff which can go on here... ;)

The above scenario is just a theory, but the theory with some quite non-null probability. Instead of hotplugging the disks, one can do a reboot having flaky ide/scsi cables or whatnot, so that disks will be detected on/off randomly...

Probably it is a good idea to test utime too, in additional to event counters, in mdadm's Assemble.c (as comments says but code disagrees). Maybe list of faulty components in every superblock too. And refuse to assemble the array if an inconsistency like this is detected (unelss --force is specified)... But the logic becomes quite.. problematic...

/mjt

#2 lore raw
In reply to a message not in the archive
Quoted 2 lines · Michael Tokarev

I just come across an interesting situation, here's the scenario.

[snip]

Quoted 18 lines

Now we have an interesting situation. Both superblocks in d1 and d2 are identical, event counts are the same, both are clean. Things wich are different:
utime - on d1 it is "more recent" (provided we haven't touched
the system clock ofcourse)
on d1, d2 is marked as faulty
on d2, d1 is marked as faulty.

Neither of the conditions are checked by mdadm.

So, mdadm just starts a clean RAID1 array composed of two drives with different data on them. And noone noticies this fact (fsck which is reading from one disk goes ok), until some time later when some app reports data corruption (reading from another disk); you go check what's going on, notice there's no data corruption (reading from 1st disk), suspects memory and.. it's quite a long list of possible bad stuff which can go on here... ;)

Quoted 7 lines

The above scenario is just a theory, but the theory with some quite non-null probability. Instead of hotplugging the disks, one can do a reboot having flaky ide/scsi cables or whatnot, so that disks will be detected on/off randomly...

Probably it is a good idea to test utime too, in additional to event counters, in mdadm's Assemble.c (as comments says but code disagrees).

Humn, please don't.

I rely on MD assembling arrays if their event counters match but the utimes don't all the time. Happens quite often that a controller fails or something like that and you accidentally loose 2 disks in a raid5.

I still want to be able to force the array to be assembled in these cases. I'm still on 2.4 btw, don't know if there's a better way to do it in 2.6 than manipulating the event counters.

(Thinking about it, it would be perfect if the array would instantly go into read-only mode whenever it is degraded to a non-redundant state. That way there's a higher chance of assembling a working array afterwards?)

#3 lore raw
In reply to Michael Tokarev
Quoted 3 lines · Michael Tokarev

I just come across an interesting situation, here's the scenario.

C'mon, there's plenty of ways for you to shoot yourself in the feet. :)

L.

Signature · 6 lines
Luca Berra -- [email protected]
       Communication Media & Services S.r.l.
/"\
\ /     ASCII RIBBON CAMPAIGN
 X        AGAINST HTML MAIL
/ \