Skip to contentSkip to conversation

Playing CD's on 48K-only hardware without resampling...

DISCUSSION Philip Prindeville 2 participants 2 messages Aug 22, 2005

lore
Share & tools
lore
#0 lore raw

Is there a way to transcode CD PCM streams into
DTS so that they can be played without having to
upconvert the signal to 48kHz?

-Philip

-------------------------------------------------------
SF.Net email is Sponsored by the Better Software Conference & EXPO September 19-22, 2005 * San Francisco, CA * Development Lifecycle Practices Agile & Plan-Driven Development * Managing Projects & Teams * Testing & QA Security * Process Improvement & Measurement * http://www.sqe.com/bsce5sf

#1 lore raw
Quoted 6 lines · Philip Prindeville

Is there a way to transcode CD PCM streams into
DTS so that they can be played without having to
upconvert the signal to 48kHz?

-Philip

A CD PCM stream converted to DTS would produce a 44.1khz DTS frame, which of course would also not play on 48K-only hardware.
The sound playing application should be doing the resampling. I have added support for this into xine. So, if it detects a sound card that can only do 48Khz, xine uses high quality resamplers instead and then outputs to alsa at 48Khz.