patch for bug 1806
Jaroslav,
I posted this patch to bug 1806 a while back, and have been awaiting a reply or commit. It currently reports the Locked/No Signal text backwards in envy24control, since i was using an older version of envy24control when I wrote the original code. The Locked/No Signal test was recently reversed in envy24control cvs, so the test in my code needs to be reversed as well. Here is the patch, once again.
Doug
--
http://nostar.net/
? 1010lt_wordclock_status_correction.diff
Index: pci/ice1712/delta.c
===================================================================
RCS file: /cvsroot/alsa/alsa-kernel/pci/ice1712/delta.c,v retrieving revision 1.25
ice1712/delta.c +1 -1
@@ -412,7 +412,7 @@if (snd_i2c_sendbytes (ice->cs8427, ®,1 ) !=1 )snd_printk (KERN_ERR "unable to send register 0x%x byte to CS8427\n" , reg);snd_i2c_readbytes (ice->cs8427, ®,1 ); - ucontrol->value.integer.value[0 ] = (reg ?0 :1 ); + ucontrol->value.integer.value[0 ] = (reg ?1 :0 );return 0 ; }
At Fri, 24 Feb 2006 18:49:40 -0500,
Quoted 7 lines · Doug McLain
I posted this patch to bug 1806 a while back, and have been awaiting a reply or commit. It currently reports the Locked/No Signal text backwards in envy24control, since i was using an older version of envy24control when I wrote the original code. The Locked/No Signal test was recently reversed in envy24control cvs, so the test in my code needs to be reversed as well. Here is the patch, once again.
Thanks for the patch. I applied it to CVS now.
Takashi
-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language that extends applications into web and mobile media. Attend the live webcast and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642