multipath-tools - checker for DDN S2A8500
Hello,
When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs). Can you update hwtable.c in this way ?
multipathd logs when using 'readsector0':
[root@iotiger2 ~]# multipathd -d -v3
Jul 26 10:53:59 | --------start up-------- Jul 26 10:53:59 | read /etc/multipath.conf Jul 26 10:53:59 | dm-0: blacklisted Jul 26 10:53:59 | dm-1: blacklisted Jul 26 10:53:59 | dm-2: blacklisted Jul 26 10:53:59 | dm-3: blacklisted Jul 26 10:53:59 | hda: blacklisted Jul 26 10:53:59 | loop0: blacklisted Jul 26 10:53:59 | loop1: blacklisted Jul 26 10:53:59 | loop2: blacklisted Jul 26 10:53:59 | loop3: blacklisted Jul 26 10:53:59 | loop4: blacklisted Jul 26 10:53:59 | loop5: blacklisted Jul 26 10:53:59 | loop6: blacklisted Jul 26 10:53:59 | loop7: blacklisted Jul 26 10:53:59 | ram0: blacklisted Jul 26 10:53:59 | ram1: blacklisted Jul 26 10:53:59 | ram2: blacklisted ... Jul 26 10:53:59 | sdc: not found in pathvec Jul 26 10:53:59 | sdc: mask = 0x1f Jul 26 10:53:59 | sdc: bus = 1 Jul 26 10:53:59 | sdc: dev_t = 8:32 Jul 26 10:53:59 | sdc: size = 571416576 Jul 26 10:53:59 | sdc: vendor = DDN Jul 26 10:53:59 | sdc: product = S2A 8500 Jul 26 10:53:59 | sdc: rev = 5.22 Jul 26 10:53:59 | sdc: h:b:t:l = 4:0:0:0 Jul 26 10:53:59 | sdc: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:53:59 | sdc: serial = Jul 26 10:53:59 | sdc: path checker = readsector0 (config file default) Jul 26 10:53:59 | sdc: state = 1 Jul 26 10:53:59 | sdc: checker msg is "readsector0 checker reports path is down" Jul 26 10:53:59 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:53:59 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout) Jul 26 10:53:59 | sdd: not found in pathvec Jul 26 10:53:59 | sdd: mask = 0x1f Jul 26 10:53:59 | sdd: bus = 1 Jul 26 10:53:59 | sdd: dev_t = 8:48 Jul 26 10:53:59 | sdd: size = 571416576 Jul 26 10:53:59 | sdd: vendor = DDN Jul 26 10:53:59 | sdd: product = S2A 8500 Jul 26 10:53:59 | sdd: rev = 5.22 Jul 26 10:53:59 | sdd: h:b:t:l = 4:0:0:1 Jul 26 10:53:59 | sdd: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:53:59 | sdd: serial = Jul 26 10:53:59 | sdd: path checker = readsector0 (config file default) Jul 26 10:53:59 | sdd: state = 1 Jul 26 10:53:59 | sdd: checker msg is "readsector0 checker reports path is down" Jul 26 10:53:59 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:53:59 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout) Jul 26 10:53:59 | sde: not found in pathvec
...
then, multipathd logs when using 'directio':
Jul 26 10:56:09 | --------start up-------- Jul 26 10:56:09 | read /etc/multipath.conf Jul 26 10:56:09 | dm-0: blacklisted Jul 26 10:56:09 | dm-1: blacklisted Jul 26 10:56:09 | dm-2: blacklisted Jul 26 10:56:09 | dm-3: blacklisted Jul 26 10:56:09 | dm-4: blacklisted Jul 26 10:56:09 | hda: blacklisted Jul 26 10:56:09 | loop0: blacklisted Jul 26 10:56:09 | loop1: blacklisted Jul 26 10:56:09 | loop2: blacklisted Jul 26 10:56:09 | loop3: blacklisted Jul 26 10:56:09 | loop4: blacklisted Jul 26 10:56:09 | loop5: blacklisted Jul 26 10:56:09 | loop6: blacklisted Jul 26 10:56:09 | loop7: blacklisted Jul 26 10:56:09 | ram0: blacklisted Jul 26 10:56:09 | ram1: blacklisted Jul 26 10:56:09 | ram2: blacklisted ... Jul 26 10:56:09 | sdc: not found in pathvec Jul 26 10:56:09 | sdc: mask = 0x1f Jul 26 10:56:09 | sdc: bus = 1 Jul 26 10:56:09 | sdc: dev_t = 8:32 Jul 26 10:56:09 | sdc: size = 571416576 Jul 26 10:56:09 | sdc: vendor = DDN Jul 26 10:56:09 | sdc: product = S2A 8500 Jul 26 10:56:09 | sdc: rev = 5.22 Jul 26 10:56:09 | sdc: h:b:t:l = 4:0:0:0 Jul 26 10:56:09 | sdc: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sdc: serial = Jul 26 10:56:09 | sdc: path checker = directio (config file default) Jul 26 10:56:09 | sdc: state = 0 Jul 26 10:56:09 | sdc: getprio = /bin/true (config file default) Jul 26 10:56:09 | sdc: prio = 0 Jul 26 10:56:09 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout) Jul 26 10:56:09 | sdd: not found in pathvec Jul 26 10:56:09 | sdd: mask = 0x1f Jul 26 10:56:09 | sdd: bus = 1 Jul 26 10:56:09 | sdd: dev_t = 8:48 Jul 26 10:56:09 | sdd: size = 571416576 Jul 26 10:56:09 | sdd: vendor = DDN Jul 26 10:56:09 | sdd: product = S2A 8500 Jul 26 10:56:09 | sdd: rev = 5.22 Jul 26 10:56:09 | sdd: h:b:t:l = 4:0:0:1 Jul 26 10:56:09 | sdd: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sdd: serial = Jul 26 10:56:09 | sdd: path checker = directio (config file default) Jul 26 10:56:09 | sdd: state = 0 Jul 26 10:56:09 | sdd: getprio = /bin/true (config file default) Jul 26 10:56:09 | sdd: prio = 0 Jul 26 10:56:09 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout) Jul 26 10:56:09 | sde: not found in pathvec Jul 26 10:56:09 | sde: mask = 0x1f Jul 26 10:56:09 | sde: bus = 1 Jul 26 10:56:09 | sde: dev_t = 8:64 Jul 26 10:56:09 | sde: size = 571416576 Jul 26 10:56:09 | sde: vendor = DDN Jul 26 10:56:09 | sde: product = S2A 8500 Jul 26 10:56:09 | sde: rev = 5.22 Jul 26 10:56:09 | sde: h:b:t:l = 4:0:0:2 Jul 26 10:56:09 | sde: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sde: serial = Jul 26 10:56:09 | sde: path checker = directio (config file default) Jul 26 10:56:09 | sde: state = 0 Jul 26 10:56:09 | sde: getprio = /bin/true (config file default) Jul 26 10:56:09 | sde: prio = 0 Jul 26 10:56:09 | sde: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sde: uid = 360001ff02002110102a8fe24220f0500 (callout)
...
Best regards
Signature · 1 line
Frederic TEMPORELLI
Quoted 137 lines · Frederic TEMPORELLI
Hello,
When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs). Can you update
hwtable.cin this way ?multipathd logs when using 'readsector0':
[root@iotiger2 ~]# multipathd -d -v3
Jul 26 10:53:59 | --------start up-------- Jul 26 10:53:59 | read /etc/multipath.conf Jul 26 10:53:59 | dm-0: blacklisted Jul 26 10:53:59 | dm-1: blacklisted Jul 26 10:53:59 | dm-2: blacklisted Jul 26 10:53:59 | dm-3: blacklisted Jul 26 10:53:59 | hda: blacklisted Jul 26 10:53:59 | loop0: blacklisted Jul 26 10:53:59 | loop1: blacklisted Jul 26 10:53:59 | loop2: blacklisted Jul 26 10:53:59 | loop3: blacklisted Jul 26 10:53:59 | loop4: blacklisted Jul 26 10:53:59 | loop5: blacklisted Jul 26 10:53:59 | loop6: blacklisted Jul 26 10:53:59 | loop7: blacklisted Jul 26 10:53:59 | ram0: blacklisted Jul 26 10:53:59 | ram1: blacklisted Jul 26 10:53:59 | ram2: blacklisted ... Jul 26 10:53:59 | sdc: not found in pathvec Jul 26 10:53:59 | sdc: mask = 0x1f Jul 26 10:53:59 | sdc: bus = 1 Jul 26 10:53:59 | sdc: dev_t = 8:32 Jul 26 10:53:59 | sdc: size = 571416576 Jul 26 10:53:59 | sdc: vendor = DDN Jul 26 10:53:59 | sdc: product = S2A 8500 Jul 26 10:53:59 | sdc: rev = 5.22 Jul 26 10:53:59 | sdc: h:b:t:l = 4:0:0:0 Jul 26 10:53:59 | sdc: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:53:59 | sdc: serial = Jul 26 10:53:59 | sdc: path checker = readsector0 (config file default) Jul 26 10:53:59 | sdc: state = 1 Jul 26 10:53:59 | sdc: checker msg is "readsector0 checker reports path is down" Jul 26 10:53:59 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:53:59 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout) Jul 26 10:53:59 | sdd: not found in pathvec Jul 26 10:53:59 | sdd: mask = 0x1f Jul 26 10:53:59 | sdd: bus = 1 Jul 26 10:53:59 | sdd: dev_t = 8:48 Jul 26 10:53:59 | sdd: size = 571416576 Jul 26 10:53:59 | sdd: vendor = DDN Jul 26 10:53:59 | sdd: product = S2A 8500 Jul 26 10:53:59 | sdd: rev = 5.22 Jul 26 10:53:59 | sdd: h:b:t:l = 4:0:0:1 Jul 26 10:53:59 | sdd: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:53:59 | sdd: serial = Jul 26 10:53:59 | sdd: path checker = readsector0 (config file default) Jul 26 10:53:59 | sdd: state = 1 Jul 26 10:53:59 | sdd: checker msg is "readsector0 checker reports path is down" Jul 26 10:53:59 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:53:59 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout) Jul 26 10:53:59 | sde: not found in pathvec...
then, multipathd logs when using 'directio':
Jul 26 10:56:09 | --------start up-------- Jul 26 10:56:09 | read /etc/multipath.conf Jul 26 10:56:09 | dm-0: blacklisted Jul 26 10:56:09 | dm-1: blacklisted Jul 26 10:56:09 | dm-2: blacklisted Jul 26 10:56:09 | dm-3: blacklisted Jul 26 10:56:09 | dm-4: blacklisted Jul 26 10:56:09 | hda: blacklisted Jul 26 10:56:09 | loop0: blacklisted Jul 26 10:56:09 | loop1: blacklisted Jul 26 10:56:09 | loop2: blacklisted Jul 26 10:56:09 | loop3: blacklisted Jul 26 10:56:09 | loop4: blacklisted Jul 26 10:56:09 | loop5: blacklisted Jul 26 10:56:09 | loop6: blacklisted Jul 26 10:56:09 | loop7: blacklisted Jul 26 10:56:09 | ram0: blacklisted Jul 26 10:56:09 | ram1: blacklisted Jul 26 10:56:09 | ram2: blacklisted ... Jul 26 10:56:09 | sdc: not found in pathvec Jul 26 10:56:09 | sdc: mask = 0x1f Jul 26 10:56:09 | sdc: bus = 1 Jul 26 10:56:09 | sdc: dev_t = 8:32 Jul 26 10:56:09 | sdc: size = 571416576 Jul 26 10:56:09 | sdc: vendor = DDN Jul 26 10:56:09 | sdc: product = S2A 8500 Jul 26 10:56:09 | sdc: rev = 5.22 Jul 26 10:56:09 | sdc: h:b:t:l = 4:0:0:0 Jul 26 10:56:09 | sdc: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sdc: serial = Jul 26 10:56:09 | sdc: path checker = directio (config file default) Jul 26 10:56:09 | sdc: state = 0 Jul 26 10:56:09 | sdc: getprio = /bin/true (config file default) Jul 26 10:56:09 | sdc: prio = 0 Jul 26 10:56:09 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout) Jul 26 10:56:09 | sdd: not found in pathvec Jul 26 10:56:09 | sdd: mask = 0x1f Jul 26 10:56:09 | sdd: bus = 1 Jul 26 10:56:09 | sdd: dev_t = 8:48 Jul 26 10:56:09 | sdd: size = 571416576 Jul 26 10:56:09 | sdd: vendor = DDN Jul 26 10:56:09 | sdd: product = S2A 8500 Jul 26 10:56:09 | sdd: rev = 5.22 Jul 26 10:56:09 | sdd: h:b:t:l = 4:0:0:1 Jul 26 10:56:09 | sdd: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sdd: serial = Jul 26 10:56:09 | sdd: path checker = directio (config file default) Jul 26 10:56:09 | sdd: state = 0 Jul 26 10:56:09 | sdd: getprio = /bin/true (config file default) Jul 26 10:56:09 | sdd: prio = 0 Jul 26 10:56:09 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout) Jul 26 10:56:09 | sde: not found in pathvec Jul 26 10:56:09 | sde: mask = 0x1f Jul 26 10:56:09 | sde: bus = 1 Jul 26 10:56:09 | sde: dev_t = 8:64 Jul 26 10:56:09 | sde: size = 571416576 Jul 26 10:56:09 | sde: vendor = DDN Jul 26 10:56:09 | sde: product = S2A 8500 Jul 26 10:56:09 | sde: rev = 5.22 Jul 26 10:56:09 | sde: h:b:t:l = 4:0:0:2 Jul 26 10:56:09 | sde: tgt_node_name = 0x20000001ff0302a8 Jul 26 10:56:09 | sde: serial = Jul 26 10:56:09 | sde: path checker = directio (config file default) Jul 26 10:56:09 | sde: state = 0 Jul 26 10:56:09 | sde: getprio = /bin/true (config file default) Jul 26 10:56:09 | sde: prio = 0 Jul 26 10:56:09 | sde: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default) Jul 26 10:56:09 | sde: uid = 360001ff02002110102a8fe24220f0500 (callout)
Quoted 2 lines
...
Have you tested the 'tur' checker?
I'd generally prefer that one as it doesn't require a disk read ...
Cheers,
Hannes
Signature · 4 lines
Dr. Hannes Reinecke [email protected] SuSE Linux Products GmbH S390 & zSeries Maxfeldstraße 5 +49 911 74053 688 90409 Nürnberg http://www.suse.de
Quoted 8 lines · Frederic TEMPORELLI
Hello,
When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs).
Can you updatehwtable.cin this way ?
Ok, will do.
BTW, I'm enlisted as maintainer of the tools defaults for this hardware but I never came close to one of these beasts.
If you happen to have a long/mid-term access to DDN arrays, I'd be happy to enlist you, or whoever Bull engineer, as maintainer.
This charge is nothing formal nor heavy : just be prepared to receive one mail a year asking the hows and whys of Linux multipath on this hardware :)
Please let me know how you feel about that.
Regards,
cvaroqui