Hello,

When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs). Can you update hwtable.c in this way ?

multipathd logs when using 'readsector0':

[root@iotiger2 ~]# multipathd -d -v3

Jul 26 10:53:59 | --------start up--------
Jul 26 10:53:59 | read /etc/multipath.conf
Jul 26 10:53:59 | dm-0: blacklisted
Jul 26 10:53:59 | dm-1: blacklisted
Jul 26 10:53:59 | dm-2: blacklisted
Jul 26 10:53:59 | dm-3: blacklisted
Jul 26 10:53:59 | hda: blacklisted
Jul 26 10:53:59 | loop0: blacklisted
Jul 26 10:53:59 | loop1: blacklisted
Jul 26 10:53:59 | loop2: blacklisted
Jul 26 10:53:59 | loop3: blacklisted
Jul 26 10:53:59 | loop4: blacklisted
Jul 26 10:53:59 | loop5: blacklisted
Jul 26 10:53:59 | loop6: blacklisted
Jul 26 10:53:59 | loop7: blacklisted
Jul 26 10:53:59 | ram0: blacklisted
Jul 26 10:53:59 | ram1: blacklisted
Jul 26 10:53:59 | ram2: blacklisted
...
Jul 26 10:53:59 | sdc: not found in pathvec
Jul 26 10:53:59 | sdc: mask = 0x1f
Jul 26 10:53:59 | sdc: bus = 1
Jul 26 10:53:59 | sdc: dev_t = 8:32
Jul 26 10:53:59 | sdc: size = 571416576
Jul 26 10:53:59 | sdc: vendor = DDN
Jul 26 10:53:59 | sdc: product = S2A 8500
Jul 26 10:53:59 | sdc: rev = 5.22
Jul 26 10:53:59 | sdc: h:b:t:l = 4:0:0:0
Jul 26 10:53:59 | sdc: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:53:59 | sdc: serial =
Jul 26 10:53:59 | sdc: path checker = readsector0 (config file default)
Jul 26 10:53:59 | sdc: state = 1
Jul 26 10:53:59 | sdc: checker msg is "readsector0 checker reports path is down"
Jul 26 10:53:59 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:53:59 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout)
Jul 26 10:53:59 | sdd: not found in pathvec
Jul 26 10:53:59 | sdd: mask = 0x1f
Jul 26 10:53:59 | sdd: bus = 1
Jul 26 10:53:59 | sdd: dev_t = 8:48
Jul 26 10:53:59 | sdd: size = 571416576
Jul 26 10:53:59 | sdd: vendor = DDN
Jul 26 10:53:59 | sdd: product = S2A 8500
Jul 26 10:53:59 | sdd: rev = 5.22
Jul 26 10:53:59 | sdd: h:b:t:l = 4:0:0:1
Jul 26 10:53:59 | sdd: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:53:59 | sdd: serial =
Jul 26 10:53:59 | sdd: path checker = readsector0 (config file default)
Jul 26 10:53:59 | sdd: state = 1
Jul 26 10:53:59 | sdd: checker msg is "readsector0 checker reports path is down"
Jul 26 10:53:59 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:53:59 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout)
Jul 26 10:53:59 | sde: not found in pathvec

...

then, multipathd logs when using 'directio':

Jul 26 10:56:09 | --------start up--------
Jul 26 10:56:09 | read /etc/multipath.conf
Jul 26 10:56:09 | dm-0: blacklisted
Jul 26 10:56:09 | dm-1: blacklisted
Jul 26 10:56:09 | dm-2: blacklisted
Jul 26 10:56:09 | dm-3: blacklisted
Jul 26 10:56:09 | dm-4: blacklisted
Jul 26 10:56:09 | hda: blacklisted
Jul 26 10:56:09 | loop0: blacklisted
Jul 26 10:56:09 | loop1: blacklisted
Jul 26 10:56:09 | loop2: blacklisted
Jul 26 10:56:09 | loop3: blacklisted
Jul 26 10:56:09 | loop4: blacklisted
Jul 26 10:56:09 | loop5: blacklisted
Jul 26 10:56:09 | loop6: blacklisted
Jul 26 10:56:09 | loop7: blacklisted
Jul 26 10:56:09 | ram0: blacklisted
Jul 26 10:56:09 | ram1: blacklisted
Jul 26 10:56:09 | ram2: blacklisted
...
Jul 26 10:56:09 | sdc: not found in pathvec
Jul 26 10:56:09 | sdc: mask = 0x1f
Jul 26 10:56:09 | sdc: bus = 1
Jul 26 10:56:09 | sdc: dev_t = 8:32
Jul 26 10:56:09 | sdc: size = 571416576
Jul 26 10:56:09 | sdc: vendor = DDN
Jul 26 10:56:09 | sdc: product = S2A 8500
Jul 26 10:56:09 | sdc: rev = 5.22
Jul 26 10:56:09 | sdc: h:b:t:l = 4:0:0:0
Jul 26 10:56:09 | sdc: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sdc: serial =
Jul 26 10:56:09 | sdc: path checker = directio (config file default)
Jul 26 10:56:09 | sdc: state = 0
Jul 26 10:56:09 | sdc: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sdc: prio = 0
Jul 26 10:56:09 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout)
Jul 26 10:56:09 | sdd: not found in pathvec
Jul 26 10:56:09 | sdd: mask = 0x1f
Jul 26 10:56:09 | sdd: bus = 1
Jul 26 10:56:09 | sdd: dev_t = 8:48
Jul 26 10:56:09 | sdd: size = 571416576
Jul 26 10:56:09 | sdd: vendor = DDN
Jul 26 10:56:09 | sdd: product = S2A 8500
Jul 26 10:56:09 | sdd: rev = 5.22
Jul 26 10:56:09 | sdd: h:b:t:l = 4:0:0:1
Jul 26 10:56:09 | sdd: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sdd: serial =
Jul 26 10:56:09 | sdd: path checker = directio (config file default)
Jul 26 10:56:09 | sdd: state = 0
Jul 26 10:56:09 | sdd: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sdd: prio = 0
Jul 26 10:56:09 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout)
Jul 26 10:56:09 | sde: not found in pathvec
Jul 26 10:56:09 | sde: mask = 0x1f
Jul 26 10:56:09 | sde: bus = 1
Jul 26 10:56:09 | sde: dev_t = 8:64
Jul 26 10:56:09 | sde: size = 571416576
Jul 26 10:56:09 | sde: vendor = DDN
Jul 26 10:56:09 | sde: product = S2A 8500
Jul 26 10:56:09 | sde: rev = 5.22
Jul 26 10:56:09 | sde: h:b:t:l = 4:0:0:2
Jul 26 10:56:09 | sde: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sde: serial =
Jul 26 10:56:09 | sde: path checker = directio (config file default)
Jul 26 10:56:09 | sde: state = 0
Jul 26 10:56:09 | sde: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sde: prio = 0
Jul 26 10:56:09 | sde: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sde: uid = 360001ff02002110102a8fe24220f0500 (callout)

...

Best regards

Signature · 1 line
Frederic TEMPORELLI
#1 lore raw
Quoted 137 lines · Frederic TEMPORELLI

Hello,

When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs). Can you update hwtable.c in this way ?

multipathd logs when using 'readsector0':

[root@iotiger2 ~]# multipathd -d -v3

Jul 26 10:53:59 | --------start up--------
Jul 26 10:53:59 | read /etc/multipath.conf
Jul 26 10:53:59 | dm-0: blacklisted
Jul 26 10:53:59 | dm-1: blacklisted
Jul 26 10:53:59 | dm-2: blacklisted
Jul 26 10:53:59 | dm-3: blacklisted
Jul 26 10:53:59 | hda: blacklisted
Jul 26 10:53:59 | loop0: blacklisted
Jul 26 10:53:59 | loop1: blacklisted
Jul 26 10:53:59 | loop2: blacklisted
Jul 26 10:53:59 | loop3: blacklisted
Jul 26 10:53:59 | loop4: blacklisted
Jul 26 10:53:59 | loop5: blacklisted
Jul 26 10:53:59 | loop6: blacklisted
Jul 26 10:53:59 | loop7: blacklisted
Jul 26 10:53:59 | ram0: blacklisted
Jul 26 10:53:59 | ram1: blacklisted
Jul 26 10:53:59 | ram2: blacklisted
...
Jul 26 10:53:59 | sdc: not found in pathvec
Jul 26 10:53:59 | sdc: mask = 0x1f
Jul 26 10:53:59 | sdc: bus = 1
Jul 26 10:53:59 | sdc: dev_t = 8:32
Jul 26 10:53:59 | sdc: size = 571416576
Jul 26 10:53:59 | sdc: vendor = DDN
Jul 26 10:53:59 | sdc: product = S2A 8500
Jul 26 10:53:59 | sdc: rev = 5.22
Jul 26 10:53:59 | sdc: h:b:t:l = 4:0:0:0
Jul 26 10:53:59 | sdc: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:53:59 | sdc: serial =
Jul 26 10:53:59 | sdc: path checker = readsector0 (config file default)
Jul 26 10:53:59 | sdc: state = 1
Jul 26 10:53:59 | sdc: checker msg is "readsector0 checker reports path is down"
Jul 26 10:53:59 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:53:59 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout)
Jul 26 10:53:59 | sdd: not found in pathvec
Jul 26 10:53:59 | sdd: mask = 0x1f
Jul 26 10:53:59 | sdd: bus = 1
Jul 26 10:53:59 | sdd: dev_t = 8:48
Jul 26 10:53:59 | sdd: size = 571416576
Jul 26 10:53:59 | sdd: vendor = DDN
Jul 26 10:53:59 | sdd: product = S2A 8500
Jul 26 10:53:59 | sdd: rev = 5.22
Jul 26 10:53:59 | sdd: h:b:t:l = 4:0:0:1
Jul 26 10:53:59 | sdd: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:53:59 | sdd: serial =
Jul 26 10:53:59 | sdd: path checker = readsector0 (config file default)
Jul 26 10:53:59 | sdd: state = 1
Jul 26 10:53:59 | sdd: checker msg is "readsector0 checker reports path is down"
Jul 26 10:53:59 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:53:59 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout)
Jul 26 10:53:59 | sde: not found in pathvec

...

then, multipathd logs when using 'directio':

Jul 26 10:56:09 | --------start up--------
Jul 26 10:56:09 | read /etc/multipath.conf
Jul 26 10:56:09 | dm-0: blacklisted
Jul 26 10:56:09 | dm-1: blacklisted
Jul 26 10:56:09 | dm-2: blacklisted
Jul 26 10:56:09 | dm-3: blacklisted
Jul 26 10:56:09 | dm-4: blacklisted
Jul 26 10:56:09 | hda: blacklisted
Jul 26 10:56:09 | loop0: blacklisted
Jul 26 10:56:09 | loop1: blacklisted
Jul 26 10:56:09 | loop2: blacklisted
Jul 26 10:56:09 | loop3: blacklisted
Jul 26 10:56:09 | loop4: blacklisted
Jul 26 10:56:09 | loop5: blacklisted
Jul 26 10:56:09 | loop6: blacklisted
Jul 26 10:56:09 | loop7: blacklisted
Jul 26 10:56:09 | ram0: blacklisted
Jul 26 10:56:09 | ram1: blacklisted
Jul 26 10:56:09 | ram2: blacklisted
...
Jul 26 10:56:09 | sdc: not found in pathvec
Jul 26 10:56:09 | sdc: mask = 0x1f
Jul 26 10:56:09 | sdc: bus = 1
Jul 26 10:56:09 | sdc: dev_t = 8:32
Jul 26 10:56:09 | sdc: size = 571416576
Jul 26 10:56:09 | sdc: vendor = DDN
Jul 26 10:56:09 | sdc: product = S2A 8500
Jul 26 10:56:09 | sdc: rev = 5.22
Jul 26 10:56:09 | sdc: h:b:t:l = 4:0:0:0
Jul 26 10:56:09 | sdc: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sdc: serial =
Jul 26 10:56:09 | sdc: path checker = directio (config file default)
Jul 26 10:56:09 | sdc: state = 0
Jul 26 10:56:09 | sdc: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sdc: prio = 0
Jul 26 10:56:09 | sdc: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sdc: uid = 360001ff02002110102a8fe1c220f0100 (callout)
Jul 26 10:56:09 | sdd: not found in pathvec
Jul 26 10:56:09 | sdd: mask = 0x1f
Jul 26 10:56:09 | sdd: bus = 1
Jul 26 10:56:09 | sdd: dev_t = 8:48
Jul 26 10:56:09 | sdd: size = 571416576
Jul 26 10:56:09 | sdd: vendor = DDN
Jul 26 10:56:09 | sdd: product = S2A 8500
Jul 26 10:56:09 | sdd: rev = 5.22
Jul 26 10:56:09 | sdd: h:b:t:l = 4:0:0:1
Jul 26 10:56:09 | sdd: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sdd: serial =
Jul 26 10:56:09 | sdd: path checker = directio (config file default)
Jul 26 10:56:09 | sdd: state = 0
Jul 26 10:56:09 | sdd: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sdd: prio = 0
Jul 26 10:56:09 | sdd: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sdd: uid = 360001ff02002110102a8fe20220f0300 (callout)
Jul 26 10:56:09 | sde: not found in pathvec
Jul 26 10:56:09 | sde: mask = 0x1f
Jul 26 10:56:09 | sde: bus = 1
Jul 26 10:56:09 | sde: dev_t = 8:64
Jul 26 10:56:09 | sde: size = 571416576
Jul 26 10:56:09 | sde: vendor = DDN
Jul 26 10:56:09 | sde: product = S2A 8500
Jul 26 10:56:09 | sde: rev = 5.22
Jul 26 10:56:09 | sde: h:b:t:l = 4:0:0:2
Jul 26 10:56:09 | sde: tgt_node_name = 0x20000001ff0302a8
Jul 26 10:56:09 | sde: serial =
Jul 26 10:56:09 | sde: path checker = directio (config file default)
Jul 26 10:56:09 | sde: state = 0
Jul 26 10:56:09 | sde: getprio = /bin/true (config file default)
Jul 26 10:56:09 | sde: prio = 0
Jul 26 10:56:09 | sde: getuid = /sbin/scsi_id -g -u -s /block/%n (config file default)
Jul 26 10:56:09 | sde: uid = 360001ff02002110102a8fe24220f0500 (callout)
Quoted 2 lines

...

Have you tested the 'tur' checker?
I'd generally prefer that one as it doesn't require a disk read ...

Cheers,

Hannes

Signature · 4 lines
Dr. Hannes Reinecke			[email protected]
SuSE Linux Products GmbH		S390 & zSeries
Maxfeldstraße 5				+49 911 74053 688
90409 Nürnberg				http://www.suse.de
#2 lore raw
In reply to Frederic TEMPORELLI
Quoted 8 lines · Frederic TEMPORELLI

Hello,

When using multipath-tools 0.4.7, I would like to reports that DDN S2A8500 disk array reports a wrong status whith 'readsector0' checker. 'directio' seems to be the right checker for such storage system (see following logs).
Can you update hwtable.c in this way ?

Ok, will do.

BTW, I'm enlisted as maintainer of the tools defaults for this hardware but I never came close to one of these beasts.

If you happen to have a long/mid-term access to DDN arrays, I'd be happy to enlist you, or whoever Bull engineer, as maintainer.

This charge is nothing formal nor heavy : just be prepared to receive one mail a year asking the hows and whys of Linux multipath on this hardware :)

Please let me know how you feel about that.

Regards,
cvaroqui