2.6.18-rt7: rollover with 32-bit cycles_t

DISCUSSION Kevin Hilman 4 participants 6 messages Nov 8, 2006 – Nov 9, 2006

lore
Share & tools
lore
#0 lore raw

On ARM, I'm noticing the 'bug' message from check_critical_timing() where two calls to get_cycles() are compared and the 2nd is assumed to be >= the first.

This isn't properly handling the case of rollover which occurs relatively often with fast hardware clocks and 32-bit cycle counters.

Is this really a bug? If the get_cycles() can be assumed to run between 0 and (cycles_t)~0, using the right unsigned math could get a proper delta even in the rollover case. Is this a safe assumption?

Kevin

#1 lore raw
Quoted 10 lines · Kevin Hilman

On ARM, I'm noticing the 'bug' message from check_critical_timing() where two calls to get_cycles() are compared and the 2nd is assumed to be >= the first.

This isn't properly handling the case of rollover which occurs relatively often with fast hardware clocks and 32-bit cycle counters.

Is this really a bug? If the get_cycles() can be assumed to run between 0 and (cycles_t)~0, using the right unsigned math could get a proper delta even in the rollover case. Is this a safe assumption?

I was concerned about that as well back when I was getting the instrumentation functional on the pxa270 as the rollover could be as short as ~8s which wasn't really long enough for test validation. However there is a /64 prescaler on that ARM core (and others) which can function as a bandaid and extend the range to ~8minutes.

I wasn't able to convince myself in a quick read of the code if roll over was being detected/corrected (though it certainly may). But even if not the only requirement needed to do so would be to assure any two consecutive data points logged per CPU were spaced apart less than the counter's wrap interval. Given the periodic events being logged in the normal course of operation this condition would certainly be met.

-john

Signature · 1 line
[email protected]
#4 lore raw
In reply to Kevin Hilman
Quoted 10 lines · Kevin Hilman

On ARM, I'm noticing the 'bug' message from check_critical_timing() where two calls to get_cycles() are compared and the 2nd is assumed to be >= the first.

This isn't properly handling the case of rollover which occurs relatively often with fast hardware clocks and 32-bit cycle counters.

Is this really a bug? If the get_cycles() can be assumed to run between 0 and (cycles_t)~0, using the right unsigned math could get a proper delta even in the rollover case. Is this a safe assumption?

Seems like the check should really be using something like time_before() time_after() which takes the rollover into account .. What I don't understand is why we don't see those on x86 ..

Daniel

#5 lore raw
Quoted 3 lines · Daniel Walker

Seems like the check should really be using something like time_before() time_after() which takes the rollover into account .. What I don't understand is why we don't see those on x86 ..

Probably due to the fact it is a 64-bit counter. Even with a free running rate of 10Ghz it would take nearly 60 years to wrap.

On PPC and ARM 32-bit counters seems to be common which limits range unless a prescaler is available. The better solution is to detect wrap as a prescaled 32 bit measurement will eventually run out of usable resolution as core frequency increases. That is assuming 64-bit counters don't eventually show up in these architectures.

-john

Signature · 1 line
[email protected]
#2 lore raw
In reply to john cooper
Quoted 19 lines · john cooper
Quoted 10 lines · Kevin Hilman

On ARM, I'm noticing the 'bug' message from check_critical_timing() where two calls to get_cycles() are compared and the 2nd is assumed to be >= the first.

This isn't properly handling the case of rollover which occurs relatively often with fast hardware clocks and 32-bit cycle counters.

Is this really a bug? If the get_cycles() can be assumed to run between 0 and (cycles_t)~0, using the right unsigned math could get a proper delta even in the rollover case. Is this a safe assumption?

I was concerned about that as well back when I was getting the instrumentation functional on the pxa270 as the rollover could be as short as ~8s which wasn't really long enough for test validation. However there is a /64 prescaler on that ARM core (and others) which can function as a bandaid and extend the range to ~8minutes.

Quoted 7 lines

I wasn't able to convince myself in a quick read of the code if roll over was being detected/corrected (though it certainly may). But even if not the only requirement needed to do so would be to assure any two consecutive data points logged per CPU were spaced apart less than the counter's wrap interval. Given the periodic events being logged in the normal course of operation this condition would certainly be met.

Looking closer, given the assumptions you stated, I'm pretty convinced that that check and 'bug' is unncessary in the normal case. The delta generated with unsigned math is correct.

However, it seems this check is more intended to check for broken/backward-running clocks. In which case, time_after() or equivalent should be used.

Here's a patch to use time_after() in the 32-bit case, but we probably really need time_after() macros which can handle 32- or 64-bit types.

kernel/latency_trace.c +7 -1
Index: linux-2.6.18/kernel/latency_trace.c
===================================================================
@@ -1609,8 +1609,14 @@ check_critical_timing(int cpu, struct cp
 	 * is fair to be reported):
 	 */
 	T2 = get_cycles();
-	if (T2 < T1)
+
+	/* check for buggy clocks, handling wrap for 32-bit clocks */
+	if (TYPE_EQUAL(cycles_t, unsigned long)) {
+		if (time_after(T1, T2))
+			printk("bug: %08x < %08x!\n", T2, T1);
+	} else if (T2 < T1)
 		printk("bug: %016Lx < %016Lx!\n", T2, T1);
+	
 	delta = T2-T0;
 
 	latency = cycles_to_usecs(delta);
#3 lore raw

kernel/latency_trace.c check_critical_timing(int cpu, struct cp · line 1619

Quoted 9 lines · Kevin Hilman
kernel/latency_trace.c +7 -1
-	if (T2 < T1)
+
+	/* check for buggy clocks, handling wrap for 32-bit clocks */
+	if (TYPE_EQUAL(cycles_t, unsigned long)) {
+		if (time_after(T1, T2))
+			printk("bug: %08x < %08x!\n", T2, T1);
+	} else if (T2 < T1)
 		printk("bug: %016Lx < %016Lx!\n", T2, T1);
+	

ok, i have applied this one.

Ingo