Using different configuration for arrays with identical vendor/product
Hey. I've got an EMC CX200 and a CX3-40 in my SAN. The latter one supports ALUA, which I'm using as much as I can, the former does not. The hosts need to be able to access volumes on both the arrays at the same time.
Unfortunately the volumes on both of these boxes have vendor «DGC» and product «RAID 5», so making two different device sections for them with different hardware_handler and path_checker settings isn't trivial. I figured I could simply override the two settings in the multipath{} blocks for volumes on the CX200, making the device{} block specific for the CX3-40. Doesn't appear to work, though, the path_checker- and hardware_handler-settings in the multipath{} blocks appears to be silently ignored.
Am I out of luck or is there any other way to do what I want?
For reference, this is the device section I use for the CX200 in standard «trespassing» mode:
device {
vendor DGC.* product RAID.* hardware_handler "1 emc" path_checker emc_clariion prio_callout "/sbin/mpath_prio_emc /dev/%n" features "1 queue_if_no_path"
path_grouping_policy group_by_prio
failback immediate
}
And for the CX3-40 in ALUA mode:
device {
vendor DGC.* product RAID.* hardware_handler "0" path_checker tur prio_callout "/sbin/mpath_prio_emc /dev/%n" features "1 queue_if_no_path"
path_grouping_policy group_by_prio
failback immediate
}
These both work fine on hosts that only connect to one of the arrays at a time.
Regards
Signature · 1 line
Tore Anderson
RE: Using different configuration for arrays with identicalvendor/product
Hi Tore.
You should be able to use the emc_handler for both arrays.
Depending on the distro you are using only implicit ALUA is supported, explicit ALUA is in being worked on for upcoming distros. Whether the storage group within the array attached to the server is ALUA or not is determined by the failover mode you set for the host on that array. At the server side you will not know the difference between the two failover modes, PNR or ALUA.
Regards,
Wayne.
EMC Corp
-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Tore Anderson
Sent: Friday, March 28, 2008 7:24 AM
To: [email protected]
Subject: [dm-devel] Using different configuration for arrays with identicalvendor/product
Hey. I've got an EMC CX200 and a CX3-40 in my SAN. The latter one supports ALUA, which I'm using as much as I can, the former does not. The hosts need to be able to access volumes on both the arrays at the same time.
Unfortunately the volumes on both of these boxes have vendor <DGC> and product <RAID 5>, so making two different device sections for them with different hardware_handler and path_checker settings isn't trivial. I figured I could simply override the two settings in the multipath{} blocks for volumes on the CX200, making the device{} block specific for the CX3-40. Doesn't appear to work, though, the path_checker- and hardware_handler-settings in the multipath{} blocks appears to be silently ignored.
Am I out of luck or is there any other way to do what I want?
For reference, this is the device section I use for the CX200 in standard <trespassing> mode:
device {
vendor DGC.* product RAID.* hardware_handler "1 emc" path_checker emc_clariion prio_callout "/sbin/mpath_prio_emc /dev/%n" features "1 queue_if_no_path"
path_grouping_policy group_by_prio
failback immediate
}
And for the CX3-40 in ALUA mode:
device {
vendor DGC.* product RAID.* hardware_handler "0" path_checker tur prio_callout "/sbin/mpath_prio_emc /dev/%n" features "1 queue_if_no_path"
path_grouping_policy group_by_prio
failback immediate
}
These both work fine on hosts that only connect to one of the arrays at a time.
Regards
Signature · 6 lines
Tore Anderson -- dm-devel mailing list [email protected] https://www.redhat.com/mailman/listinfo/dm-devel
Re: Using different configuration for arrays with identicalvendor/product
Quoted 7 lines
You should be able to use the
emc_handlerfor both arrays.
Depending on the distro you are using only implicit ALUA is supported, explicit ALUA is in being worked on for upcoming distros. Whether the storage group within the array attached to the server is ALUA or not is determined by the failover mode you set for the host on that array. At the server side you will not know the difference between the two failover modes, PNR or ALUA.
Hi Wayne, thanks for your reply.
So I can use the emc_clariion hardware handler towards an array configured for ALUA mode. Wasn't aware of that. I feel it's better to let the array handle the trespassing on its own based on the ratio of «non-optimal» I/O operations (using hardware_handler 0), but I can live with host-initiated trespasses on PG swithces/inits.
Anyway - there's still the problem of the path_checker. If I'm using «emc_clariion» for the array configured for ALUA mode (CLARiiON Open, mode 4), all paths is perceived to be failed. If I'm using «tur» for the array configured for PNR mode (CLARiiON Open, mode 1), the passive path is perceived to be failed.
Hence, if I use «emc_clariion» I won't be able to access the volumes on the CX3-40 at all, while if I use «tur» dm-multipath won't switch PGs when there's a (real) failure on the active path to the CX200. None of these are acceptable alternatives for production use, so the only workaround I've found so far is to configure the CX3-40 to use PNR mode (which sucks since ALUA is way better). Do you have another trick up your sleeve for me?
Regards