Support for Meilhaus serial boards - patch (kernel 2.6.28)
Subsystems (2)
Dear Linux-serial team
Meilhaus (PCI ID: 0x1402) ME90xx, ME91xx and ME93xx support added. The are RS232 and RS422/485 PCI serial boards.
This patch was tested on x86 and x86_64 machines.
Could you added this to main tree, please.
Best regards,
Krzysztof Gantzke
Signature · 5 lines
Krzysztof Gantzke Meilhaus Electronic GmbH Fischerstr. 2 D-82178 Puchheim
drivers/serial//8250.c +49 -0
@@ -2494,20 +2494,68 @@ static int serial8250_verify_port(struct uart_port *port, struct serial_struct *ser) {if (ser->irq >= nr_irqs || ser->irq <0 || ser->baud_base <9600 || ser->type <PORT_UNKNOWN || ser->type >=ARRAY_SIZE (uart_config) || ser->type ==PORT_CIRRUS || ser->type ==PORT_STARTECH )return -EINVAL ;return 0 ; } +static int +serial8250_set_rs232 (struct uart_port *port) +{ +struct uart_8250_port *up = (struct uart_8250_port *) port; + +if (up->port.type ==PORT_16C950 ){ + up->acr &= ~0x18 ; +serial_icr_write (up,UART_ACR , up->acr); + } +else if (up->port.type ==PORT_16550A ){ +serial_outp (up,0x8 ,serial_inp (up,0x8 ) & ~0x20 ); + } + +return 0 ; +} + +static int +serial8250_set_rs485 (struct uart_port *port) +{ +struct uart_8250_port *up = (struct uart_8250_port *) port; + +if (up->port.type ==PORT_16C950 ){ + up->acr |=0x18 ; +serial_icr_write (up,UART_ACR , up->acr); + } +else if (up->port.type ==PORT_16550A ){ +serial_outp (up,0x8 ,serial_inp (up,0x8 ) |0x20 ); + } +else { +return -ENOIOCTLCMD ; + } + +return 0 ; +} + +static int +serial8250_ioctl (struct uart_port *port,unsigned int cmd,unsigned long uarg){ +switch (cmd){ +case TIOCSRS232 : +return serial8250_set_rs232 (port); +case TIOCSRS485 : +return serial8250_set_rs485 (port); +default : +return -ENOIOCTLCMD ; + } +return 0 ; +} +static const char *serial8250_type (struct uart_port *port) {int type = port->type;if (type >=ARRAY_SIZE (uart_config)) type =0 ;return uart_config[type].name; }
@@ -2522,20 +2570,21 @@ static struct uart_ops serial8250_pops = .break_ctl = serial8250_break_ctl, .startup = serial8250_startup, .shutdown = serial8250_shutdown, .set_termios = serial8250_set_termios, .pm = serial8250_pm, .type = serial8250_type, .release_port = serial8250_release_port, .request_port = serial8250_request_port, .config_port = serial8250_config_port, .verify_port = serial8250_verify_port, + .ioctl = serial8250_ioctl, #ifdef CONFIG_CONSOLE_POLL .poll_get_char = serial8250_get_poll_char, .poll_put_char = serial8250_put_poll_char, #endif };static struct uart_8250_port serial8250_ports[UART_NR ];static void __init serial8250_isa_init_ports (void ) {
src/linux-2.6.28/drivers/serial//8250_pci.c renamed from work/linux-sources/linux-2.6.28-me9x00/drivers/serial//8250_pci.c +240 -0
380 lines not on this page · raw message
arch/x86/include/asm//ioctls.h +5 -0
@@ -49,20 +49,25 @@#define TIOCGSID 0x5429/* Return the session ID of FD */ #define TCGETS2 _IOR('T', 0x2A, struct termios2)#define TCSETS2 _IOW('T', 0x2B, struct termios2)#define TCSETSW2 _IOW('T', 0x2C, struct termios2)#define TCSETSF2 _IOW('T', 0x2D, struct termios2)#define TIOCGRS485 0x542E#define TIOCSRS485 0x542F#define TIOCGPTN _IOR('T', 0x30, unsigned int)/* Get Pty Number (of pty-mux device) */ #define TIOCSPTLCK _IOW('T', 0x31, int)/* Lock/unlock Pty */ + +/* Meilhaus */ +#define TIOCGRS232 _IOR('T', 0x48, unsigned int) +#define TIOCSRS232 _IOW('T', 0x48, unsigned int) +#define TCGETX 0x5432/* SYS5 TCGETX compatibility */ #define TCSETX 0x5433#define TCSETXF 0x5434#define TCSETXW 0x5435#define FIONCLEX 0x5450#define FIOCLEX 0x5451#define FIOASYNC 0x5452#define TIOCSERCONFIG 0x5453#define TIOCSERGWILD 0x5454
Quoted 6 lines · On Monday 19 January 2009 16:10:32 Krzysztof Gantzke wrote:
Dear Linux-serial team
Meilhaus (PCI ID:0x1402) ME90xx, ME91xx and ME93xx support added. The are RS232 and RS422/485 PCI serial boards.
This patch was tested on x86 andx86_64machines.Could you added this to main tree, please.
NAK. You should not add an ioctl to revert to RS232 mode but check serial_rs485.flags in TIOCSRS485. Enable RS485 when SER_RS485_ENABLED is set, disable it otherwise.
You should also probably base your patch to 8250.c on top of Matthias Fuchs' patch ('[PATCH V3] serial: Add ioctl to enable auto rs485 mode with some Exar UARTs').
Best regards,
Signature · 9 lines
Laurent Pinchart CSE Semaphore Belgium Chaussee de Bruxelles, 732A B-1410 Waterloo Belgium T +32 (2) 387 42 59 F +32 (2) 387 42 75