Hi guys,

Iam using dm-multipath for a Infortrend dual controller F16F-R4031-6 FC system.

Version details are :

device-mapper-multipath-0.4.7-17.el5
device-mapper-1.02.24-1.el5
device-mapper-event-1.02.24-1.el5

OS : Red Hat Enterprise Linux Server release 5.2 (Tikanga) Kernel : 2.6.18-92.1.10.el5 #1 SMP x86_64 x86_64 x86_64

Recently, one of the RAID controllers failed and caused multipath to fail both active paths

device-mapper: multipath: Failing path 8:32. sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1976776672
device-mapper: multipath: Failing path 8:48. sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

This caused the ext3 filesystem to go into a read only mode. Full IO errors is at http://pastebin.com/m103325d9

The dual controller storage unit and the host server (Only 1 Server using 2 Qlogic FC HBAs) are hooked upto two different Qlogic SanBox FC switch for redundancy.

multipath.conf : http://pastebin.com/m4c7da817
multipath -v4 -ll : http://pastebin.com/m7d863925

I have checked the logs on the FC switch and the HBAs
and i dont see any event which suggest both paths failed at once. Even the errors i captured out of dmesg show that one of the physical disks that makes up dm-0 had 'end_request: I/O errors' while the other did not have any such error.

sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

At this point iam wondering how paths 8:32 and 8:48 failed together - considering both paths are through two different FC switches. Any suggestions on this ?

Additionaly, I have looked at the mailing list archives & annotated conf files and found two options a) failback and b) no_path_retry. What would be the best recommended values for these on a dual controller setup like mine ?

It would also be helpful if someone could share infotrend specific settings multipath settings.

TIA
Dushyanth

#1 lore raw
Quoted 4 lines · On Mon, 2009-03-16 at 21:51 +0530, [email protected] wrote:

Hi guys,

Iam using dm-multipath for a Infortrend dual controller F16F-R4031-6 FC system.

Can you post your multipath.conf somewhere? (pastebin is fine).

Regards,
Bryn.

#3 lore raw
In reply to [email protected]
Quoted 11 lines · On Mon, 2009-03-16 at 21:51 +0530, [email protected] wrote:

Hi guys,

Iam using dm-multipath for a Infortrend dual controller F16F-R4031-6 FC system.

Version details are :

device-mapper-multipath-0.4.7-17.el5
device-mapper-1.02.24-1.el5
device-mapper-event-1.02.24-1.el5

Quoted 7 lines

OS : Red Hat Enterprise Linux Server release 5.2 (Tikanga) Kernel : 2.6.18-92.1.10.el5 #1 SMP x86_64 x86_64 x86_64

Recently, one of the RAID controllers failed and caused multipath to fail both active paths

device-mapper: multipath: Failing path 8:32.

8:32 has failed here.

Quoted 1 line

sd 2:0:0:0: SCSI error: return code = 0x00020000

error code 20000 mean the BUS is busy.

Quoted 2 lines

end_request: I/O error, dev sdd, sector 1976776672
device-mapper: multipath: Failing path 8:48.

and 8:48 failed because of that.

Do you know which one was supposed to fail when the RAID controller failed ? (my guess is it is 8:32).

looks like for whatever reason the other SCSI bus became busy.

Quoted 46 lines

sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

This caused the ext3 filesystem to go into a read only mode. Full IO errors is at http://pastebin.com/m103325d9

The dual controller storage unit and the host server (Only 1 Server using 2 Qlogic FC HBAs) are hooked upto two different Qlogic SanBox FC switch for redundancy.

multipath.conf : http://pastebin.com/m4c7da817
multipath -v4 -ll : http://pastebin.com/m7d863925

I have checked the logs on the FC switch and the HBAs
and i dont see any event which suggest both paths failed at once. Even the errors i captured out of dmesg show that one of the physical disks that makes up dm-0 had 'end_request: I/O errors' while the other did not have any such error.

sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

At this point iam wondering how paths 8:32 and 8:48 failed together - considering both paths are through two different FC switches. Any suggestions on this ?

Additionaly, I have looked at the mailing list archives & annotated conf files and found two options a) failback and b) no_path_retry. What would be the best recommended values for these on a dual controller setup like mine ?

It would also be helpful if someone could share infotrend specific settings multipath settings.

TIA
Dushyanth

--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel

#4 lore raw

Hi,

Quoted 8 lines
Quoted 1 line

device-mapper: multipath: Failing path 8:32.

8:32 has failed here.

Quoted 1 line

sd 2:0:0:0: SCSI error: return code = 0x00020000

error code 20000 mean the BUS is busy.

Quoted 7 lines
Quoted 2 lines

end_request: I/O error, dev sdd, sector 1976776672
device-mapper: multipath: Failing path 8:48.

and 8:48 failed because of that.

Do you know which one was supposed to fail when the RAID controller failed ? (my guess is it is 8:32).

The alert on the storage device was (sorry for not including this earlier)

257 Critical 2009-03-11 10:38:43 ALERT:Redundant Controller Failure Detected (Slot B)

I also found additional logs from /var/log/messages which i did not check earlier.

Mar 11 10:32:46 multipathd: sdc: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:32 in map infortrend01
Mar 11 10:32:46 multipathd: infortrend01: remaining active paths: 1
Mar 11 10:32:46 multipathd: sdd: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:48 in map infortrend01
Mar 11 10:32:46 multipathd: infortrend01: remaining active paths: 0
Mar 11 10:32:46 multipathd: dm-0: add map (uevent)
Mar 11 10:32:46 multipathd: dm-0: devmap already registered
Mar 11 10:32:46 multipathd: dm-0: add map (uevent)
Mar 11 10:32:47 multipathd: dm-0: devmap already registered
Mar 11 10:32:47 multipathd: sdd: readsector0 checker reports path is down

So, it looks like 8:32 was the path which had the failed controller and during the switch over multipath must have detected 8:48 as busy? if this is right, then it must be due to the infortrend device itself.

Quoted 6 lines

looks like for whatever reason the other SCSI bus became busy.

Quoted 4 lines

sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

Iam assuming it must have been busy for a few secs during the switch over and the multipath config doesn't wait enough for the switchover to work.

Any advice on the below values ?

Quoted 7 lines

Additionaly, I have looked at the mailing list archives & annotated conf files and found two options a) failback and b) no_path_retry. What would be the best recommended values for these on a dual controller setup like mine ?

It would also be helpful if someone could share infotrend specific settings multipath settings.

TIA
Dushyanth

#5 lore raw
Quoted 23 lines · On Tue, 2009-03-17 at 02:33 +0530, [email protected] wrote:

Hi,

Quoted 8 lines
Quoted 1 line

device-mapper: multipath: Failing path 8:32.

8:32 has failed here.

Quoted 1 line

sd 2:0:0:0: SCSI error: return code = 0x00020000

error code 20000 mean the BUS is busy.

Quoted 7 lines
Quoted 2 lines

end_request: I/O error, dev sdd, sector 1976776672
device-mapper: multipath: Failing path 8:48.

and 8:48 failed because of that.

Do you know which one was supposed to fail when the RAID controller failed ? (my guess is it is 8:32).

The alert on the storage device was (sorry for not including this earlier)

257 Critical 2009-03-11 10:38:43 ALERT:Redundant Controller Failure Detected (Slot B)

Quoted 8 lines

I also found additional logs from /var/log/messages which i did not check earlier.

Mar 11 10:32:46 multipathd: sdc: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:32 in map infortrend01
Mar 11 10:32:46 multipathd: infortrend01: remaining active paths: 1
Mar 11 10:32:46 multipathd: sdd: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:48 in map infortrend01

Does this timing correspond to when you turned off the controller ?

Quoted 13 lines
Mar 11 10:32:46 multipathd: infortrend01: remaining active paths: 0
Mar 11 10:32:46 multipathd: dm-0: add map (uevent)
Mar 11 10:32:46 multipathd: dm-0: devmap already registered
Mar 11 10:32:46 multipathd: dm-0: add map (uevent)
Mar 11 10:32:47 multipathd: dm-0: devmap already registered
Mar 11 10:32:47 multipathd: sdd: readsector0 checker reports path is down

So, it looks like 8:32 was the path which had the failed controller and during the switch over multipath must have detected 8:48 as busy? if this is right, then it must be due to the infortrend device itself.

Quoted 1 line

looks like for whatever reason the other SCSI bus became busy.

Quoted 9 lines
Quoted 4 lines
Quoted 4 lines

sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 1967432880 sd 2:0:0:0: SCSI error: return code = 0x00020000
end_request: I/O error, dev sdd, sector 161647296

Iam assuming it must have been busy for a few secs during the switch over and the multipath config doesn't wait enough for the switchover to work.

Answer to your previous question would help here :)

Set no_path_retry to "queue", which would queue the I/Os when "all" the paths fail.

If the behavior seen above was caused by the storage and will be rectified in an acceptable (to the user) time, then this parameter setting would solve your problem.

BTW, have you seen the I/O successfully been sent to the lun (both paths
- you can use iostat to check it) before you failed the controller ? (I am trying to see if your config settings are proper).

Quoted 4 lines

Any advice on the below values ?

Quoted 2 lines

Additionaly, I have looked at the mailing list archives & annotated conf files and found two options a) failback and b) no_path_retry. What would

Failback would be useful only when you have different path groups. In a multibus setup like yours it is of no value.

Quoted 13 lines
Quoted 5 lines

be the best recommended values for these on a dual controller setup like mine ?

It would also be helpful if someone could share infotrend specific settings multipath settings.

TIA
Dushyanth

--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel

#6 lore raw

Hi,

Quoted 5 lines
Quoted 5 lines

257 Critical 2009-03-11 10:38:43 ALERT:Redundant Controller Failure Detected (Slot B)

I also found additional logs from /var/log/messages which i did not check earlier.

Quoted 7 lines
Quoted 5 lines
Mar 11 10:32:46 multipathd: sdc: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:32 in map infortrend01
Mar 11 10:32:46 multipathd: infortrend01: remaining active paths: 1
Mar 11 10:32:46 multipathd: sdd: readsector0 checker reports path is down
Mar 11 10:32:46 multipathd: checker failed path 8:48 in map infortrend01

Does this timing correspond to when you turned off the controller ?

This is when the controller failed. The controller shutdown happened much later.

Quoted 6 lines
Quoted 1 line

Iam assuming it must have been busy for a few secs during the switch over and the multipath config doesn't wait enough for the switchover to work.

Answer to your previous question would help here :)

Set no_path_retry to "queue", which would queue the I/Os when "all" the paths fail.

Iam not sure if i can do this as well. Aren't we creating an illusion that the storage subsystem is fine and queuing requests when actually the subsystem is gone ? What actually is done for queuing and there must be some limits for the queue as well right ?

Quoted 3 lines

If the behavior seen above was caused by the storage and will be rectified in an acceptable (to the user) time, then this parameter setting would solve your problem.

Iam checking this with infortrend.

Quoted 3 lines

BTW, have you seen the I/O successfully been sent to the lun (both paths
- you can use iostat to check it) before you failed the controller ? (I am trying to see if your config settings are proper).

Iam doing a post mortem of the redundant controller failure here :). I dug out what was done after the controller failure.

* Primary Controller failed and failover to secondary did not work
* Multipath failed both paths and ext3 went read only
* Postgres crashed
* When they logged in and ran (multipath -v2 -ll), they saw both paths active - I cannot find any multipath log entries which shows paths reinstated until 11:50 - which was after controller shutdown and power cycle.
* The filesystem was mounted again (without fsck) and database started (This answers your question abt IO to the LUNs i think)
* Postgres recovered and was shutdown immediately and /data unmounted.
* After this the controllers on the infotrend was shutdown and the device power cycled.

PS : Iam digging up the entire multipath logs instead of posting snippets here - will add to pastebin and send the link over

TIA
Dushyanth