Hello,

I've been configuring SATA link power management (Documentation/scsi/link_power_management_policy.txt) on servers which use software RAID for a while, but I happened to come across this in the ICH9 datasheet:

"
For reliable device removal notification while in AHCI operation without the use of interlock switches (surprise removal), interface power management should be disabled for the associated port. See Section 7.3.1 of the AHCI Specification for more information.
"

Is this actually an issue from a libata point of view? Do I need to ensure that link power management is disabled prior to hot-removal, and if so, I suppose link_power_management_policy.txt should be updated to reflect this...

On a related topic, is there any way to do anything other than "surprise" removal with libata? It'd be nice to put a drive to sleep (e.g. with "hdparm -Y"), and ensure that nothing comes along and causes the drive to be reset and spin the drive attached to that SATA port back up prior to a removal and reinsertion.

I'm assuming that physically unplugging a non-spinning drive is preferable to unplugging a spinning one from a drive longevity point of view (I use SATA drives as removable backup medium in some cases).

Cheers,

Tim.

#1 lore raw
Quoted 9 lines · Tim Small

On a related topic, is there any way to do anything other than "surprise" removal with libata? It'd be nice to put a drive to sleep (e.g. with "hdparm -Y"), and ensure that nothing comes along and causes the drive to be reset and spin the drive attached to that SATA port back up prior to a removal and reinsertion.

I'm assuming that physically unplugging a non-spinning drive is preferable to unplugging a spinning one from a drive longevity point of view (I use SATA drives as removable backup medium in some cases).

Unplugging the SATA cable is fine. I wouldn't yank power while it's actively storing data, though.

Jeff

#2 lore raw
In reply to Tim Small

Hello,

Quoted 11 lines · Tim Small

"
For reliable device removal notification while in AHCI operation without the use of interlock switches (surprise removal), interface power management should be disabled for the associated port. See Section 7.3.1 of the AHCI Specification for more information.
"

Is this actually an issue from a libata point of view? Do I need to ensure that link power management is disabled prior to hot-removal, and if so, I suppose link_power_management_policy.txt should be updated to reflect this...

Yeap, libata wouldn't know the device is yanked out. It will find out later when it tries to issue a command later tho. It could be a problem if you hot-swap the drive. libata wouldn't know that devices have been exchanged.

Quoted 5 lines

On a related topic, is there any way to do anything other than "surprise" removal with libata? It'd be nice to put a drive to sleep (e.g. with "hdparm -Y"), and ensure that nothing comes along and causes the drive to be reset and spin the drive attached to that SATA port back up prior to a removal and reinsertion.

echo 1 > /sys/block/sdX/device/delete

Quoted 3 lines

I'm assuming that physically unplugging a non-spinning drive is preferable to unplugging a spinning one from a drive longevity point of view (I use SATA drives as removable backup medium in some cases).

Yeah, you'll induce an emergency unload if you remove power while the drive is spinning, but drives are designed to deal with certain number of those events and if it doesn't happen regularly, you don't need to worry about it.

Thanks.

Signature · 1 line
tejun
#3 lore raw
In reply to Tim Small
Quoted 15 lines · On Thu, 19 Mar 2009 04:03:37 -0700 Tim Small <[email protected]> wrote:

Hello,

I've been configuring SATA link power management (Documentation/scsi/link_power_management_policy.txt) on servers which use software RAID for a while, but I happened to come across this in the ICH9 datasheet:

"
For reliable device removal notification while in AHCI operation without the use of interlock switches (surprise removal), interface power management should be disabled for the associated port. See Section 7.3.1 of the AHCI Specification for more information.
"

Quoted 4 lines

Is this actually an issue from a libata point of view? Do I need to ensure that link power management is disabled prior to hot-removal, and if so, I suppose link_power_management_policy.txt should be updated to reflect this...

Hi,
Yes - this is an issue. Right now we disable hotplug when link power management is enabled because when your link is in a lower power state it cannot detect the phy state changes. Most platforms I've seen do not support the interlock switches - so ATM link pwr management and hotplug are mutually excludive. I agree that the documentation should reflect this - would you like to submit a patch to the link_power_management_policy.txt file?

Thanks!
Kristen