lvm2: sync error handling on secondary mirror in dmeventd
PATCH 1/1 lvm2: sync error handling on secondary mirror in dmeventd
Set the ME_FAILURE flag if the error is related to sync on the secondary mirror. A sync error on the secondary mirror occurs by a write I/O and the error can be treated as the regular write error on mirror legs.
Signed-off-by Takahiro Yasui <[email protected]>
--- daemons/dmeventd/plugins/mirror/dmeventd_mirror.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-)
daemons/dmeventd/plugins/mirror/dmeventd_mirror.c +4 -2
@@ -68,10 +68,12 @@ static int _process_status_code(const chsyslog (LOG_ERR ,"%s device %s flush failed.\n" , dev_type, dev_name); r =ME_FAILURE ; - }else if (status_code =='S' ) + }else if (status_code =='S' ) {syslog (LOG_ERR ,"%s device %s sync failed.\n" , dev_type, dev_name); -else if (status_code =='R' ) +if (!strcmp (dev_type,"Secondary mirror" )) + r =ME_FAILURE ; + }else if (status_code =='R' )syslog (LOG_ERR ,"%s device %s read failed.\n" , dev_type, dev_name);else if (status_code !='A' ) {