Fix raid-6 read-error correction in degraded state
PATCH 1/1 Fix raid-6 read-error correction in degraded state
Fix: Raid-6 was not trying to correct a read-error when in singly-degraded state and was instead dropping one more device, going to doubly-degraded state. This patch fixes this behaviour.
Signed-off-by Gabriele A. Trombetti <[email protected]>
Reported-by Janos Haar <[email protected]>
--------
drivers/md/raid5.c 2010-04-28 13:08:15.000000000 +0200 renamed from drivers/md/raid5.c 2010-04-28 13:05:03.000000000 +0200 +1 -1
@@ -1527,7 +1527,7 @@ static void raid5_end_read_request(struc clear_bit(R5_UPTODATE, &sh->dev[i].flags); atomic_inc(&rdev->read_errors); - if (conf->mddev->degraded) + if (conf->mddev->degraded >= conf->max_degraded) printk_rl(KERN_WARNING "raid5:%s: read error not correctable " "(sector %llu on %s).\n",
---------------------------------------------------------------
Thanks,
Gabriele A. Trombetti