Skip to contentSkip to conversation

md/raid6: Fix raid-6 read-error correction in degraded state

PATCH In review Gabriele A. Trombetti 2 participants 2 messages May 5, 2010 MD RAID

lore
Share & tools
lore
#0 lore raw

PATCH v2 1/1 md/raid6: Fix raid-6 read-error correction in degraded state

Fix: md raid-6 was not trying to correct a read-error when in singly-degraded state and was instead dropping one more device, going to doubly-degraded state. This patch fixes this behaviour.

--------

drivers/md/raid5.c 2010-04-28 13:08:15.000000000 +0200 renamed from drivers/md/raid5.c 2010-04-28 13:05:03.000000000 +0200 +1 -1
@@ -1527,7 +1527,7 @@ static void raid5_end_read_request(struc
 
                clear_bit(R5_UPTODATE, &sh->dev[i].flags);
                atomic_inc(&rdev->read_errors);
-               if (conf->mddev->degraded)
+               if (conf->mddev->degraded >= conf->max_degraded)
                        printk_rl(KERN_WARNING
                                  "raid5:%s: read error not correctable "
                                  "(sector %llu on %s).\n",

---------------------------------------------------------------

Resending patch:
v2: added "Tested-by" line, subsystem mentioned in summary line, body explanation mentions "md"

Thanks,
Gabriele A. Trombetti

#1 lore raw

Thanks. This is now in my queue.
I may even submit it for .34 as that doesn't seem as close as I thought.

NeilBrown

Quoted 30 lines · On Wed, 05 May 2010 21:17:53 +0200 "Gabriele A. Trombetti"…

Fix: md raid-6 was not trying to correct a read-error when in singly-degraded state and was instead dropping one more device, going to doubly-degraded state. This patch fixes this behaviour.

--------
--- linux-2.6.34-rc5-git8-vanilla/drivers/md/raid5.c 2010-04-28
13:05:03.000000000 +0200
+++ linux-2.6.34-rc5-git8/drivers/md/raid5.c 2010-04-28
13:08:15.000000000 +0200

drivers/md/raid5.c 2010-04-28 13:08:15.000000000 +0200 renamed from drivers/md/raid5.c 2010-04-28 13:05:03.000000000 +0200 +1 -2
@@ -1527,7 +1527,7 @@ static void raid5_end_read_request(struc
 
                 clear_bit(R5_UPTODATE, &sh->dev[i].flags);
                 atomic_inc(&rdev->read_errors);
-               if (conf->mddev->degraded)
+               if (conf->mddev->degraded >= conf->max_degraded)
                         printk_rl(KERN_WARNING
                                   "raid5:%s: read error not correctable "
                                   "(sector %llu on %s).\n",
 
---------------------------------------------------------------

Resending patch:
v2: added "Tested-by" line, subsystem mentioned in summary line, body explanation mentions "md"

Thanks,