Fix SJA1000 command register writes on SMP systems
Subsystems (3)
PATCH 1/1 Fix SJA1000 command register writes on SMP systems
The SJA1000 command register is concurrently written in the rx-path to free the receive buffer _and_ in the tx-path to start the transmission. On SMP systems this leads to a write stall in the tx-path, which can be solved by adding some locking for the command register in the SMP case.
Thanks to Klaus Hitschler for the original fix and detailed problem description.
This patch applies on net-2.6 and (with some small offsets) on net-next-2.6. It is also a candidate for the stable series.
---
drivers/net/can/sja1000/sja1000.c +24 -3
@@ -84,6 +84,27 @@ static struct can_bittiming_const sja1000_bittiming_const = { .brp_inc = 1, }; +static void sja1000_write_cmdreg (struct sja1000_priv *priv,u8 val) +{ +/* the command register needs some locking on SMP systems */ + +#ifdef CONFIG_SMP + +unsigned long flags; + +spin_lock_irqsave (&priv->cmdreg_lock, flags); + priv->write_reg (priv,REG_CMR , val); + priv->read_reg (priv,REG_SR ); +spin_unlock_irqrestore (&priv->cmdreg_lock, flags); + +#else + +/* write to the command register without locking */ + priv->write_reg (priv,REG_CMR , val); + +#endif +} +static int sja1000_probe_chip (struct net_device *dev) {struct sja1000_priv *priv =netdev_priv (dev);
@@ -297,7 +318,7 @@ static netdev_tx_t sja1000_start_xmit(struct sk_buff *skb,can_put_echo_skb (skb, dev,0 ); - priv->write_reg (priv,REG_CMR ,CMD_TR ); +sja1000_write_cmdreg (priv,CMD_TR );return NETDEV_TX_OK ; }
@@ -346,7 +367,7 @@ static void sja1000_rx(struct net_device *dev) cf->can_id = id;/* release receive buffer */ - priv->write_reg (priv,REG_CMR ,CMD_RRB ); +sja1000_write_cmdreg (priv,CMD_RRB );netif_rx (skb);
@@ -374,7 +395,7 @@ static int sja1000_err(struct net_device *dev, uint8_t isrc, uint8_t status) cf->data[1 ] =CAN_ERR_CRTL_RX_OVERFLOW ; stats->rx_over_errors++; stats->rx_errors++; - priv->write_reg (priv,REG_CMR ,CMD_CDO );/* clear bit */ +sja1000_write_cmdreg (priv,CMD_CDO );/* clear bit */ }if (isrc &IRQ_EI ) {
drivers/net/can/sja1000/sja1000.h +4 -0
@@ -168,6 +168,10 @@ struct sja1000_priv {void __iomem *reg_base;/* ioremap'ed address to registers */ unsigned long irq_flags;/* for request_irq() */ +#ifdef CONFIG_SMP +spinlock_t cmdreg_lock;/* lock for concurrent cmd register writes */ +#endif +u16 flags;/* custom mode flags */ u8 ocr;/* output control register */ u8 cdr;/* clock divider register */
Hi Oliver,
Quoted 4 lines · Oliver Hartkopp
The SJA1000 command register is concurrently written in the rx-path to free the receive buffer _and_ in the tx-path to start the transmission. On SMP systems this leads to a write stall in the tx-path, which can be solved by adding some locking for the command register in the SMP case.
We should explain why a write stall can happen. Here is the relavant part from the SJA1000 data sheet, 6.4.4 COMMAND REGISTER (CMR):
"Between two commands at least one internal clock cycle is needed in order to proceed. The internal clock is half of the external oscillator frequency."
Wolfgang.
Quoted 8 lines · Wolfgang Grandegger
Hi Oliver,
Quoted 4 lines · Oliver Hartkopp
The SJA1000 command register is concurrently written in the rx-path to free the receive buffer _and_ in the tx-path to start the transmission. On SMP systems this leads to a write stall in the tx-path, which can be solved by adding some locking for the command register in the SMP case.
Quoted 6 lines
We should explain why a write stall can happen. Here is the relavant part from the SJA1000 data sheet, 6.4.4 COMMAND REGISTER (CMR):
"Between two commands at least one internal clock cycle is needed in order to proceed. The internal clock is half of the external oscillator frequency."
The delay directly after the register access can only be guaranteed when there is some locking around the command register write access.
In the end it boils down to a SMP issue again as this is (from all known environments) the only case, where the problem appears in reality. This was also what i've taken from the discussion on the SocketCAN ML.
I don't stick on the patch description. Would you like to produce a different one? My Acked-by for the code remains sure :-)
Regards,
Oliver
Quoted 12 lines · Oliver Hartkopp
Quoted 11 lines · Wolfgang Grandegger
Hi Oliver,
Quoted 4 lines · Oliver Hartkopp
The SJA1000 command register is concurrently written in the rx-path to free the receive buffer _and_ in the tx-path to start the transmission. On SMP systems this leads to a write stall in the tx-path, which can be solved by adding some locking for the command register in the SMP case.
We should explain why a write stall can happen. Here is the relavant part from the SJA1000 data sheet, 6.4.4 COMMAND REGISTER (CMR):
Quoted 6 lines
Quoted 3 lines
"Between two commands at least one internal clock cycle is needed in order to proceed. The internal clock is half of the external oscillator frequency."
The delay directly after the register access can only be guaranteed when there is some locking around the command register write access.
Of course.
Quoted 3 lines
In the end it boils down to a SMP issue again as this is (from all known environments) the only case, where the problem appears in reality. This was also what i've taken from the discussion on the SocketCAN ML.
I know.
Quoted 2 lines
I don't stick on the patch description. Would you like to produce a different one? My Acked-by for the code remains sure :-)
I just suggested to mention the hardware requirements in the patch description so people can understand why we need it. Feel free to add what I wrote above.
Wolfgang.