Skip to contentSkip to conversation

Variable accuracy devices.

DISCUSSION Jonathan Cameron 2 participants 2 messages Jun 28, 2011 IIO

lore
Share & tools
lore
#0 lore raw

Hi All,

There are a couple of different types of variable accuracy drivers in three.

1) Devices with variable gain - these are well handled

2) Devices with variable number of bits per sample. Typically they will do higher accuracy at a slower rate.

3) Variable bit depths in hardware ring buffers (sca3000 only - currently glossed over).

In case 2 we have for example the adis16130 gyro driver (a very simple driver). This one doesn't currently implement buffered capture, so our only read route
is through the sysfs attributes. So my question here is whether there is
a use case for sampling at anything other than maximum accuracy if we are reading via a slow path anyway? Basically I'd like to drop the non standard interface that this driver has.

Case 3 is one I've been avoiding mainly because it only exists in one driver
right now and that one is for a long deprecated part. It is however similar
to a controllable nbit adc or indeed the adis16130 gyro. In those cases we want to be able to control the accuracy of data that is captured into a software buffer. Right now we don't have an easy way of doing this.

The solution that comes to mind is:
Additional optional callback within ring_setup_ops (it kind of fits in there if we broaden the term setup somewhat), checked by equivalent replacement of iio_show_fixed_type. If it's present, the driver is queried, if not then we use the fixed type stuff from the iio_chan_spec structure. Clearly we will also need a write function. The matching _available attribute could be done by a second callback.

What do people think?

Thanks,

Jonathan

#1 lore raw
Quoted 13 lines · Jonathan Cameron

Hi All,

There are a couple of different types of variable accuracy drivers in three.

1) Devices with variable gain - these are well handled

2) Devices with variable number of bits per sample. Typically they will do higher accuracy at a slower rate.

3) Variable bit depths in hardware ring buffers (sca3000 only - currently glossed over).

Quoted 5 lines

In case 2 we have for example the adis16130 gyro driver (a very simple driver). This one doesn't currently implement buffered capture, so our only read route
is through the sysfs attributes. So my question here is whether there is
a use case for sampling at anything other than maximum accuracy if we are reading via a slow path anyway?

I don't think so.

Quoted 2 lines

Basically I'd like to drop the non standard
interface that this driver has.

ACK

Quoted 14 lines

Case 3 is one I've been avoiding mainly because it only exists in one driver
right now and that one is for a long deprecated part. It is however similar
to a controllable nbit adc or indeed the adis16130 gyro. In those cases we want to be able to control the accuracy of data that is captured into a software buffer. Right now we don't have an easy way of doing this.

The solution that comes to mind is:
Additional optional callback within ring_setup_ops (it kind of fits in there if we broaden the term setup somewhat), checked by equivalent replacement of iio_show_fixed_type. If it's present, the driver is queried, if not then we use the fixed type stuff from the iio_chan_spec structure. Clearly we will also need a write function. The matching _available attribute could be done by a second callback.

Quoted 1 line

What do people think?

Sounds good to me.

Signature · 8 lines
Greetings,
Michael

--
Analog Devices GmbH      Wilhelm-Wagenfeld-Str. 6      80807 Muenchen
Sitz der Gesellschaft: Muenchen; Registergericht: Muenchen HRB 40368;
Geschaeftsfuehrer:Dr.Carsten Suckrow, Thomas Wessel, William A. Martin,
Margaret Seif