Hi,

we are trying to solve one problem with early printk initialization on Microblaze uart16550. I have also checked arm bootup code and the situation is the same there (NOTE: This IP is possible to use on Zynq too).

The problem is about baudrate initialization. Current code just expect that early console is initialized by previous bootloader/firmware (in our case u-boot). But if there is not initialization and directly elf is loaded there is no initialization done and kernel bootlog is shown when regular serial driver is probed.

I have create a solution which add baudrate initialization to Microblaze early printk code. And also two options how to load baudrate setting from device-tree.

Code expects that early console is specified in chosen node.

chosen {
	linux,stdout-path = "/axi@0/serial@40400000";
} ;

Code finds out which IP it is and based on that initialize early printk driver. Baudrate setting is counted from clock-frequency and current-speed defined directly in uart node.

RS232_Uart_1: serial@40400000 {
	clock-frequency = <50000000>;
	compatible = "xlnx,axi-uart16550-1.01.a", "xlnx,xps-uart16550-2.00.a", "ns16550a";
	current-speed = <115200>;
	device_type = "serial";
	reg = < 0x40400000 0x10000 >;
	reg-offset = <0x1000>;
	reg-shift = <2>;
	...irq, etc
} ;

This was the first version which is working but using current-speed is probably not the best solution.

I have also create version where baudrate is directly specified in chosen node. Clock frequency is still loaded directly from the node.

chosen {
	linux,stdout-path = "/axi@0/serial@40400000,115200";
} ;

What solution is more compatible with device-tree?

Thanks for you comments,
Michal

Signature · 4 lines
Michal Simek, Ing. (M.Eng)
w: www.monstr.eu p: +42-0-721842854
Maintainer of Linux kernel 2.6 Microblaze Linux - http://www.monstr.eu/fdt/
Microblaze U-BOOT custodian

A message that is not in the archive (sent off-list or not yet received): [email protected]

#2 lore raw
Quoted 26 lines

-----Original Message-----
From: devicetree-discuss [mailto:devicetree-discuss- bounces+dvomlehn=cisco.com-uLR06cmDAlY/[email protected]] On Behalf Of Michal Simek
Sent: Tuesday, June 26, 2012 4:17 AM
To: devicetree-discuss-uLR06cmDAlY/[email protected]
Cc: John Williams
Subject: Early printk baudrate initialization DTS description

Hi,

we are trying to solve one problem with early printk initialization on Microblaze uart16550. I have also checked arm bootup code and the situation is the same there (NOTE: This IP is possible to use on Zynq too).

The problem is about baudrate initialization. Current code just expect that early console is initialized by previous bootloader/firmware (in our case u-boot).
But if there is not initialization and directly elf is loaded there is no initialization
done and kernel bootlog is shown when regular serial driver is probed.

I have create a solution which add baudrate initialization to Microblaze early printk code.
And also two options how to load baudrate setting from device-tree.

Quoted 7 lines

Code expects that early console is specified in chosen node.

chosen {
	linux,stdout-path = "/axi@0/serial@40400000";
} ;

Code finds out which IP it is and based on that initialize early

printk

Quoted 3 lines

driver.
Baudrate setting is counted from clock-frequency and current-speed defined directly in uart node.

The terminology is not quite clear to me. Many people use the term baud rate when they mean the more accurate term "data rate" and I'm pretty sure this is what you mean, but is this different than "current-speed"?

Quoted 20 lines
RS232_Uart_1: serial@40400000 {
	clock-frequency = <50000000>;
	compatible = "xlnx,axi-uart16550-1.01.a", "xlnx,xps-uart16550-
2.00.a", "ns16550a";
	current-speed = <115200>;
	device_type = "serial";
	reg = < 0x40400000 0x10000 >;
	reg-offset = <0x1000>;
	reg-shift = <2>;
	...irq, etc
} ;

This was the first version which is working but using current-speed is probably not the best solution.

I have also create version where baudrate is directly specified in chosen node. Clock frequency is still
loaded directly from the node.

Quoted 5 lines
chosen {
	linux,stdout-path = "/axi@0/serial@40400000,115200";
} ;

What solution is more compatible with device-tree?

Since nobody else has responded for a couple of days, I'll throw out the opinion that I prefer the first solution. The second solution requires you to do additional parsing and data validation which the device tree has already done for you in the first approach. It's also consistent with the ePAPR example in
https://www.power.org/resources/downloads/Power_ePAPR_APPROVED_v1.0.pdf.

Quoted 1 line

Michal

--
David VL

A message that is not in the archive (sent off-list or not yet received): 7A9214B0DEB2074FBCA688B30B04400D04C05241-2KNrN6/[email protected]

#4 lore raw
Quoted 33 lines · David VomLehn (dvomlehn)
Quoted 26 lines

-----Original Message-----
From: devicetree-discuss [mailto:devicetree-discuss- bounces+dvomlehn=cisco.com-uLR06cmDAlY/[email protected]] On Behalf Of Michal Simek
Sent: Tuesday, June 26, 2012 4:17 AM
To: devicetree-discuss-uLR06cmDAlY/[email protected]
Cc: John Williams
Subject: Early printk baudrate initialization DTS description

Hi,

we are trying to solve one problem with early printk initialization on Microblaze uart16550. I have also checked arm bootup code and the situation is the same there (NOTE: This IP is possible to use on Zynq too).

The problem is about baudrate initialization. Current code just expect that early console is initialized by previous bootloader/firmware (in our case u-boot).
But if there is not initialization and directly elf is loaded there is no initialization
done and kernel bootlog is shown when regular serial driver is probed.

I have create a solution which add baudrate initialization to Microblaze early printk code.
And also two options how to load baudrate setting from device-tree.

Quoted 7 lines

Code expects that early console is specified in chosen node.

chosen {
	linux,stdout-path = "/axi@0/serial@40400000";
} ;

Code finds out which IP it is and based on that initialize early

Quoted 8 lines

printk

Quoted 3 lines

driver.
Baudrate setting is counted from clock-frequency and current-speed defined directly in uart node.

The terminology is not quite clear to me. Many people use the term baud rate when they mean the more accurate term "data rate" and I'm pretty sure this is what you mean, but is this different than "current-speed"?

ok. Sorry not serial expert but please correct me.

I need to read required baudrate setting (9600,...,115200, etc) which is used for communication(it should be numeric bits per second) and clock frequency. And based on the code setups baud_divisor for the baud rate generator counter.

And based on ePAPR.. Specifies the current speed of a serial device in bits per second. A boot program should set this property if it has initialized the serial device.

Quoted 25 lines
Quoted 25 lines

RS232_Uart_1: serial@40400000 {
	clock-frequency =<50000000>;
	compatible = "xlnx,axi-uart16550-1.01.a", "xlnx,xps-uart16550-
2.00.a", "ns16550a";
	current-speed =<115200>;
	device_type = "serial";
	reg =<  0x40400000 0x10000>;
	reg-offset =<0x1000>;
	reg-shift =<2>;
	...irq, etc
} ;

This was the first version which is working but using current-speed is probably not the best solution.

I have also create version where baudrate is directly specified in chosen node. Clock frequency is still
loaded directly from the node.

chosen {
	linux,stdout-path = "/axi@0/serial@40400000,115200";
} ;
Quoted 8 lines
Quoted 1 line

What solution is more compatible with device-tree?

Since nobody else has responded for a couple of days, I'll throw out the opinion that I prefer the first solution. The second solution requires you to do additional parsing and data validation which the device tree has already done for you in the first approach. It's also consistent with the ePAPR example in
https://www.power.org/resources/downloads/Power_ePAPR_APPROVED_v1.0.pdf.

This is done in early phase which means that I don't believe that there is any parsing done for the first approach too. It is simple value reading with no checking.
And yes, current-speed should be used exactly for this purpose.

Thanks,
Michal

Signature · 4 lines
Michal Simek, Ing. (M.Eng)
w: www.monstr.eu p: +42-0-721842854
Maintainer of Linux kernel 2.6 Microblaze Linux - http://www.monstr.eu/fdt/
Microblaze U-BOOT custodian