opensm/osm_perfmgr.c: Use non conflicting error codes in log messages
PATCH 1/1 opensm/osm_perfmgr.c: Use non conflicting error codes in log messages
4Cxx was already used by osm_sa.c so move perfmgr to 54xx error codes
---
opensm/osm_perfmgr.c +27 -27
@@ -183,7 +183,7 @@ static void perfmgr_mad_recv_callback(osm_madw_t * p_madw, void *bind_context,/* post this message for later processing. */ if (cl_disp_post (pm->pc_disp_h,OSM_MSG_MAD_PORT_COUNTERS , p_madw,NULL ,NULL ) !=CL_SUCCESS ) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 4C01: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 5401: " "PerfMgr Dispatcher post failed\n" );osm_mad_pool_put (pm->mad_pool, p_madw); }
@@ -212,13 +212,13 @@ static void perfmgr_mad_send_err_callback(void *bind_context,*/ if ((p_node =cl_qmap_get (&pm->monitored_map, node_guid)) ==cl_qmap_end (&pm->monitored_map)) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 4C15: GUID 0x%016" +OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 5415: GUID 0x%016" PRIx64" not found in monitored map\n" , node_guid); goto Exit; } p_mon_node = (monitored_node_t *) p_node; - OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 4C02: %s (0x%" PRIx64 + OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 5402: %s (0x%" PRIx64 ") port %u LID %u TID 0x%" PRIx64 "\n", p_mon_node->name, p_mon_node->guid, port, cl_ntoh16(p_madw->mad_addr.dest_lid),
@@ -230,7 +230,7 @@ static void perfmgr_mad_send_err_callback(void *bind_context,/* Now, validate port number */ if (port >= p_mon_node->num_ports) {cl_plock_release (&pm->osm->lock); - OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 4C16: " + OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 5416: " "Invalid port num %u for %s (GUID 0x%016" PRIx64 ") num ports %u\n", port, p_mon_node->name, p_mon_node->guid,
@@ -265,7 +265,7 @@ ib_api_status_t osm_perfmgr_bind(osm_perfmgr_t * pm, ib_net64_t port_guid)if (pm->bind_handle !=OSM_BIND_INVALID_HANDLE ) {OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C03: Multiple binds not allowed\n" ); +"ERR 5403: Multiple binds not allowed\n" ); status =IB_ERROR ; goto Exit; }
@@ -291,7 +291,7 @@ ib_api_status_t osm_perfmgr_bind(osm_perfmgr_t * pm, ib_net64_t port_guid)if (pm->bind_handle ==OSM_BIND_INVALID_HANDLE ) { status =IB_ERROR ;OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C04: Vendor specific bind failed (%s)\n" , +"ERR 5404: Vendor specific bind failed (%s)\n" ,ib_get_err_str (status)); }
@@ -307,7 +307,7 @@ static void perfmgr_mad_unbind(osm_perfmgr_t * pm) {OSM_LOG_ENTER (pm->log);if (pm->bind_handle ==OSM_BIND_INVALID_HANDLE ) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 4C05: No previous bind\n" ); +OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 5405: No previous bind\n" ); goto Exit; }osm_vendor_unbind (pm->bind_handle);
@@ -458,7 +458,7 @@ static void collect_guids(cl_map_item_t * p_map_item, void *context) mon_node =malloc (sizeof (*mon_node) +sizeof (monitored_port_t) * num_ports);if (!mon_node) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 4C06: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 5406: " "malloc failed: not handling node %s" "(GUID 0x%" PRIx64")\n" , node->print_desc, node_guid);
@@ -510,7 +510,7 @@ static void perfmgr_query_counters(cl_map_item_t * p_map_item, void *context) node =osm_get_node_by_guid (pm->subn,cl_hton64 (mon_node->guid));if (!node) {OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C07: Node \"%s\" (guid 0x%" PRIx64 +"ERR 5407: Node \"%s\" (guid 0x%" PRIx64") no longer exists so removing from PerfMgr monitoring\n" , mon_node->name, mon_node->guid);mark_for_removal (pm, mon_node);
@@ -525,7 +525,7 @@ static void perfmgr_query_counters(cl_map_item_t * p_map_item, void *context) num_ports, node->print_desc) != PERFMGR_EVENT_DB_SUCCESS) {OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C08: DB create entry failed for 0x%" +"ERR 5408: DB create entry failed for 0x%" PRIx64" (%s) : %s\n" , node_guid, node->print_desc,strerror (errno)); goto Exit;
@@ -568,7 +568,7 @@ static void perfmgr_query_counters(cl_map_item_t * p_map_item, void *context) port,IB_MAD_METHOD_GET , &mad_context);if (status !=IB_SUCCESS ) - OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 4C09: " + OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 5409: " "Failed to issue port counter query for node 0x%" PRIx64 " port %d (%s)\n", node->node_info.node_guid, port,
@@ -604,7 +604,7 @@ static int sweep_hop_1(osm_sm_t * sm) p_port =osm_get_port_by_guid (sm->p_subn, port_guid);if (!p_port) {OSM_LOG (sm->p_log,OSM_LOG_ERROR , -"ERR 4C81: No SM port object\n" ); +"ERR 5481: No SM port object\n" );return -1 ; }
@@ -631,7 +631,7 @@ static int sweep_hop_1(osm_sm_t * sm) CL_DISP_MSGID_NONE, &context);if (status !=IB_SUCCESS ) -OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 4C82: " +OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 5482: " "Request for NodeInfo failed\n" );break ;
@@ -664,14 +664,14 @@ static int sweep_hop_1(osm_sm_t * sm) CL_DISP_MSGID_NONE, &context);if (status !=IB_SUCCESS ) -OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 4C84: " +OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 5484: " "Request for NodeInfo failed\n" ); }break ;default :OSM_LOG (sm->p_log,OSM_LOG_ERROR , -"ERR 4C83: Unknown node type %d\n" , +"ERR 5483: Unknown node type %d\n" ,osm_node_get_type (p_node)); }
@@ -691,7 +691,7 @@ static unsigned is_sm_port_down(osm_sm_t * sm) p_port =osm_get_port_by_guid (sm->p_subn, port_guid);if (!p_port) {CL_PLOCK_RELEASE (sm->p_lock); -OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 4C85: " +OSM_LOG (sm->p_log,OSM_LOG_ERROR ,"ERR 5485: " "SM port with GUID:%016" PRIx64" is unknown\n" ,cl_ntoh64 (port_guid));return 1 ;
@@ -726,7 +726,7 @@ static int sweep_hop_0(osm_sm_t * sm)if (status !=IB_SUCCESS )OSM_LOG (sm->p_log,OSM_LOG_ERROR , -"ERR 4C86: Request for NodeInfo failed\n" ); +"ERR 5486: Request for NodeInfo failed\n" );return status; }
@@ -819,7 +819,7 @@ void osm_perfmgr_process(osm_perfmgr_t * pm)ib_node_info_get_local_port_num (&p_node->node_info); }else OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C87: No PerfMgr port object\n" ); +"ERR 5487: No PerfMgr port object\n" );CL_PLOCK_RELEASE (pm->sm->p_lock); }
@@ -928,7 +928,7 @@ static void perfmgr_check_oob_clear(osm_perfmgr_t * pm, cr->link_integrity < prev_err.link_integrity || cr->buffer_overrun < prev_err.buffer_overrun || cr->vl15_dropped < prev_err.vl15_dropped) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 4C0A: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 540A: " "Detected an out of band error clear " "on %s (0x%" PRIx64") port %u\n" , mon_node->name, mon_node->guid, port);
@@ -950,7 +950,7 @@ static void perfmgr_check_oob_clear(osm_perfmgr_t * pm, dc->xmit_pkts < prev_dc.xmit_pkts || dc->rcv_pkts < prev_dc.rcv_pkts) {OSM_LOG (pm->log,OSM_LOG_ERROR , -"PerfMgr: ERR 4C0B: Detected an out of band data counter " +"PerfMgr: ERR 540B: Detected an out of band data counter " "clear on node %s (0x%" PRIx64") port %u\n" , mon_node->name, mon_node->guid, port);perfmgr_db_clear_prev_dc (pm->db, mon_node->guid, port);
@@ -1027,7 +1027,7 @@ static void perfmgr_check_overflow(osm_perfmgr_t * pm, lid =get_lid (p_node, port, mon_node);cl_plock_release (&pm->osm->lock);if (lid ==0 ) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 4C0C: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 540C: " "Failed to clear counters for %s (0x%" PRIx64") port %d; failed to get lid\n" , mon_node->name, mon_node->guid, port);
@@ -1044,7 +1044,7 @@ static void perfmgr_check_overflow(osm_perfmgr_t * pm, port,IB_MAD_METHOD_SET , &mad_context);if (status !=IB_SUCCESS ) -OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 4C11: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"PerfMgr: ERR 5411: " "Failed to send clear counters MAD for %s (0x%" PRIx64") port %d\n" , mon_node->name, mon_node->guid, port);
@@ -1114,7 +1114,7 @@ static int16_t validate_redir_pkey(osm_perfmgr_t *pm, ib_net16_t pkey)if (!p_port) {CL_PLOCK_RELEASE (pm->sm->p_lock);OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C1E: No PerfMgr port object\n" ); +"ERR 541E: No PerfMgr port object\n" ); goto Exit; }if (p_port->p_physp &&osm_physp_is_valid (p_port->p_physp)) {
@@ -1148,7 +1148,7 @@ static int16_t validate_redir_pkey(osm_perfmgr_t *pm, ib_net16_t pkey) }else {CL_PLOCK_RELEASE (pm->sm->p_lock);OSM_LOG (pm->log,OSM_LOG_ERROR , -"ERR 4C20: Local PerfMgt port physp invalid\n" ); +"ERR 5420: Local PerfMgt port physp invalid\n" ); } Exit:
@@ -1185,7 +1185,7 @@ static void pc_recv_process(void *context, void *data)*/ if ((p_node =cl_qmap_get (&pm->monitored_map, node_guid)) ==cl_qmap_end (&pm->monitored_map)) { -OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 4C12: GUID 0x%016" +OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 5412: GUID 0x%016" PRIx64" not found in monitored map\n" , node_guid); goto Exit; }
@@ -1261,7 +1261,7 @@ static void pc_recv_process(void *context, void *data)/* Now, validate port number */ if (port >= p_mon_node->num_ports) {cl_plock_release (&pm->osm->lock); -OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 4C13: " +OSM_LOG (pm->log,OSM_LOG_ERROR ,"ERR 5413: " "Invalid port num %d for GUID 0x%016" PRIx64" num ports %d\n" , port, node_guid, p_mon_node->num_ports);
@@ -1287,7 +1287,7 @@ static void pc_recv_process(void *context, void *data) mad_context->perfmgr_context. mad_method, mad_context);if (status !=IB_SUCCESS ) - OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 4C14: " + OSM_LOG(pm->log, OSM_LOG_ERROR, "ERR 5414: " "Failed to send redirected MAD with method 0x%x for node 0x%" PRIx64 " port %d\n", mad_context->perfmgr_context.mad_method,
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html
Hi Hal,
Quoted 5 lines · Hal Rosenstock
4Cxx was already used by
osm_sa.cso move perfmgr to 54xx error codes---
Applied, thanks.
--
To unsubscribe from this list: send the line "unsubscribe linux-rdma" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html