Hi Everyone,

I'm using bcache with a RAID1 pair of SSDs (for the cache) with a MD-RAID10 spindle array for the backing device. On top of this is LVM. This setup is used with the Xen Hypervisor. Bcache is formatted with a sector size of 512 bytes.

If I use an LV for a Linux DomU, I get fantastic disk performance using fio (about 23k random write). However, when I use IOMeter in a Windows HVM DomU (with GPLPV drivers installed), my avg IOPS is around 4000. I am using the "default" Access Specification. Am I doing something wrong? Changing the number of workers doesn't seem to help.

Any advice is appreciated.

Thanks

A message that is not in the archive (sent off-list or not yet received): [email protected]

#2 lore raw
Quoted 10 lines · Jonathan Tripathy

Hi Everyone,

I'm using bcache with a RAID1 pair of SSDs (for the cache) with a MD-RAID10 spindle array for the backing device. On top of this is LVM. This setup is used with the Xen Hypervisor. Bcache is formatted with a sector size of 512 bytes.

If I use an LV for a Linux DomU, I get fantastic disk performance using fio (about 23k random write). However, when I use IOMeter in a Windows HVM DomU (with GPLPV drivers installed), my avg IOPS is around 4000. I am using the "default" Access Specification. Am I doing something wrong? Changing the number of workers doesn't seem to help.

Any advice is appreciated.

Thanks

Actually nvm, I forgot to enable the dist target for each of the works. Now I'm getting an avg iops of about 34k.

But this does leave me with a question: is the number of "workers" in IOMeter akin to "IO Depth" in fio?

Thanks

A message that is not in the archive (sent off-list or not yet received): [email protected]

#4 lore raw
Quoted 17 lines · Jonathan Tripathy
Quoted 16 lines · Jonathan Tripathy

Hi Everyone,

I'm using bcache with a RAID1 pair of SSDs (for the cache) with a MD-RAID10 spindle array for the backing device. On top of this is LVM. This setup is used with the Xen Hypervisor. Bcache is formatted with a sector size of 512 bytes.

If I use an LV for a Linux DomU, I get fantastic disk performance using fio (about 23k random write). However, when I use IOMeter in a Windows HVM DomU (with GPLPV drivers installed), my avg IOPS is around 4000. I am using the "default" Access Specification. Am I doing something wrong? Changing the number of workers doesn't seem to help.

Any advice is appreciated.

Quoted 7 lines
Quoted 2 lines

Thanks

Actually nvm, I forgot to enable the dist target for each of the works. Now I'm getting an avg iops of about 34k.

But this does leave me with a question: is the number of "workers" in IOMeter akin to "IO Depth" in fio?

I've not used IOmeter, but I would assume that the number of "workers" would be similar to the number of "jobs" in fio. IO depth/queue depth is the number of IO requests that are queued for processing at any one time. So, if you've got 4 workers, each keeping one IO operation queued at all times, your effective IO depth would be 4, while the IO depth for each job/worker would be 1. That's my understanding at least.

-davidc