Hi,

I'm trying to use the HSSPI controller on a S3C2416 based board but I'm having some problems.

I've added "&s3c64xx_device_spi0" to my array of platform devices and added a call to s3c64xx_spi0_set_platdata(NULL, 0, 1) before platform_add_devices(). When the kernel starts I see the following error:

s3c64xx-spi s3c6410-spi.0: Unable to acquire clock 'spi'
s3c64xx-spi: probe of s3c6410-spi.0 failed with error -2

So I reckon I'm still missing some kind of initialization. Can someone help me on this?

Best regards,
José Gonçalves

#1 lore raw

Hi José,

Am Montag, 1. Oktober 2012, 19:32:15 schrieb José Miguel Gonçalves:

Quoted 9 lines

I'm trying to use the HSSPI controller on a S3C2416 based board but I'm having some problems.

I've added "&s3c64xx_device_spi0" to my array of platform devices and added a call to s3c64xx_spi0_set_platdata(NULL, 0, 1) before platform_add_devices(). When the kernel starts I see the following error:

s3c64xx-spi s3c6410-spi.0: Unable to acquire clock 'spi'
s3c64xx-spi: probe of s3c6410-spi.0 failed with error -2

what kernel version do you use?

I.e. the clock support for the s3c64xx-spi on s3c2443 and s3c2416 was added through [1] in march - so it's not this old.

Heiko

[1] http://lists.infradead.org/pipermail/linux-arm-kernel/2012-March/089086.html

Acked-by Jaswinder Singh Acked-by Grant Likely
#2 lore raw

Hi,

Quoted 10 lines · Heiko Stübner

Hi José,

Am Montag, 1. Oktober 2012, 19:32:15 schrieb José Miguel Gonçalves:

Quoted 7 lines

I'm trying to use the HSSPI controller on a S3C2416 based board but I'm having some problems.

I've added "&s3c64xx_device_spi0" to my array of platform devices and added a call to s3c64xx_spi0_set_platdata(NULL, 0, 1) before platform_add_devices(). When the kernel starts I see the following error:

Quoted 7 lines
Quoted 2 lines

s3c64xx-spi s3c6410-spi.0: Unable to acquire clock 'spi'
s3c64xx-spi: probe of s3c6410-spi.0 failed with error -2

what kernel version do you use?

I.e. the clock support for the s3c64xx-spi on s3c2443 and s3c2416 was added through [1] in march - so it's not this old.

In this commit

commit a5238e360b715e9a1bb39d7d3537f78cc9e9e286

Author: Thomas Abraham <[email protected]>
Date:   Fri Jul 13 07:15:14 2012 +0900

spi: s3c64xx: move controller information into driver data

Platform data is used to specify controller hardware specific information such as the tx/rx fifo level mask and bit offset of rx fifo level. Such information is not suitable to be supplied from device tree. Instead, it can be moved into the driver data and removed from platform data.

All "s3c64xx-spi.0" devname fields that you added were replaced with "s3c24xx-spi.0". I wonder if that's not the reason clk_get(..., "spi"); fails in the spi-s3c64xx driver used on mach-s3c24xx. But it of course depends on the kernel version, we need to first clarify that.

arch/arm/mach-s3c24xx/common-s3c2443.c +2 -2
index aeeb2be..aeb4a24 100644
@@ -559,7 +559,7 @@ static struct clk hsmmc1_clk = {
 
 static struct clk hsspi_clk = {
        .name           = "spi",
-       .devname        = "s3c64xx-spi.0",
+       .devname        = "s3c2443-spi.0",
        .parent         = &clk_p,
        .enable         = s3c2443_clkcon_enable_p,
        .ctrlbit        = S3C2443_PCLKCON_HSSPI,
@@ -633,7 +633,7 @@ static struct clk_lookup s3c2443_clk_lookup[] = {
        CLKDEV_INIT(NULL, "clk_uart_baud2", &clk_p),
        CLKDEV_INIT(NULL, "clk_uart_baud3", &clk_esys_uart.clk),
        CLKDEV_INIT("s3c-sdhci.1", "mmc_busclk.0", &hsmmc1_clk),
-       CLKDEV_INIT("s3c64xx-spi.0", "spi_busclk0", &hsspi_clk),
+       CLKDEV_INIT("s3c2443-spi.0", "spi_busclk0", &hsspi_clk),
 };
 
 
Quoted 1 line

[1] http://lists.infradead.org/pipermail/linux-arm-kernel/2012-March/089086.html

--

Regards,
Sylwester

#3 lore raw

Am Montag, 1. Oktober 2012, 21:40:35 schrieb Sylwester Nawrocki:

Quoted 58 lines · Heiko Stübner
Quoted 11 lines

Hi José,

Am Montag, 1. Oktober 2012, 19:32:15 schrieb José Miguel Gonçalves:

Quoted 8 lines

I'm trying to use the HSSPI controller on a S3C2416 based board but I'm having some problems.

I've added "&s3c64xx_device_spi0" to my array of platform devices and added a call to s3c64xx_spi0_set_platdata(NULL, 0, 1) before platform_add_devices(). When the kernel starts I see the following error:

Quoted 7 lines
Quoted 2 lines

s3c64xx-spi s3c6410-spi.0: Unable to acquire clock 'spi'
s3c64xx-spi: probe of s3c6410-spi.0 failed with error -2

what kernel version do you use?

I.e. the clock support for the s3c64xx-spi on s3c2443 and s3c2416 was added through [1] in march - so it's not this old.

In this commit

commit a5238e360b715e9a1bb39d7d3537f78cc9e9e286

Author: Thomas Abraham <[email protected]>
Date:   Fri Jul 13 07:15:14 2012 +0900

spi: s3c64xx: move controller information into driver data

Platform data is used to specify controller hardware specific
information such as the tx/rx fifo level mask and bit offset of rx fifo level. Such information is not suitable to be supplied from device tree. Instead, it can be moved into the driver data and removed from platform data.

All "s3c64xx-spi.0" devname fields that you added were replaced with "s3c24xx-spi.0". I wonder if that's not the reason clk_get(..., "spi"); fails in the spi-s3c64xx driver used on mach-s3c24xx. But it of course depends on the kernel version, we need to first clarify that.

(quoted diff) +0 -0

b/arch/arm/mach-s3c24xx/common-s3c2443.c index aeeb2be..aeb4a24 100644

arch/arm/mach-s3c24xx/common-s3c2443.c +1 -1
@@ -559,7 +559,7 @@ static struct clk hsmmc1_clk = {
 
 static struct clk hsspi_clk = {
        .name           = "spi",
-       .devname        = "s3c64xx-spi.0",
+       .devname        = "s3c2443-spi.0",
        .parent         = &clk_p,
        .enable         = s3c2443_clkcon_enable_p,
        .ctrlbit        = S3C2443_PCLKCON_HSSPI,

arch/arm/mach-s3c24xx/common-s3c2443.c static struct clk_lookup s3c2443_clk_lookup[] = { · line 637

Quoted 6 lines
arch/arm/mach-s3c24xx/common-s3c2443.c +1 -1
@@ -633,7 +633,7 @@ static struct clk_lookup s3c2443_clk_lookup[] = {
        CLKDEV_INIT(NULL, "clk_uart_baud2", &clk_p),
        CLKDEV_INIT(NULL, "clk_uart_baud3", &clk_esys_uart.clk),
        CLKDEV_INIT("s3c-sdhci.1", "mmc_busclk.0", &hsmmc1_clk),
-       CLKDEV_INIT("s3c64xx-spi.0", "spi_busclk0", &hsspi_clk),
+       CLKDEV_INIT("s3c2443-spi.0", "spi_busclk0", &hsspi_clk),
 };

ahaa ... that's the cause. As far as I was able to determine, in the patchset only the clocks were renamed and the different device names introduced.

The spi devices did not get a function to set the name, like for the rtc, adc and nand. The devices are named s3c6410-spi by default, so it seems only the s3c64xx machines should have a working spi currently.

I'm working on a patch to fix this for all Samsung arches.

Heiko

#4 lore raw
Quoted 24 lines · Heiko Stübner
Quoted 14 lines
(quoted diff) +0 -0

b/arch/arm/mach-s3c24xx/common-s3c2443.c index aeeb2be..aeb4a24 100644

arch/arm/mach-s3c24xx/common-s3c2443.c +1 -1
@@ -559,7 +559,7 @@ static struct clk hsmmc1_clk = {
 
 static struct clk hsspi_clk = {
        .name           = "spi",
-       .devname        = "s3c64xx-spi.0",
+       .devname        = "s3c2443-spi.0",
        .parent         = &clk_p,
        .enable         = s3c2443_clkcon_enable_p,
        .ctrlbit        = S3C2443_PCLKCON_HSSPI,

arch/arm/mach-s3c24xx/common-s3c2443.c static struct clk_lookup s3c2443_clk_lookup[] = { · line 637

Quoted 6 lines
arch/arm/mach-s3c24xx/common-s3c2443.c +1 -1
@@ -633,7 +633,7 @@ static struct clk_lookup s3c2443_clk_lookup[] = {
        CLKDEV_INIT(NULL, "clk_uart_baud2", &clk_p),
        CLKDEV_INIT(NULL, "clk_uart_baud3", &clk_esys_uart.clk),
        CLKDEV_INIT("s3c-sdhci.1", "mmc_busclk.0", &hsmmc1_clk),
-       CLKDEV_INIT("s3c64xx-spi.0", "spi_busclk0", &hsspi_clk),
+       CLKDEV_INIT("s3c2443-spi.0", "spi_busclk0", &hsspi_clk),
 };

ahaa ... that's the cause. As far as I was able to determine, in the patchset only the clocks were renamed and the different device names introduced.

Quoted 3 lines

The spi devices did not get a function to set the name, like for the rtc, adc and nand. The devices are named s3c6410-spi by default, so it seems only the s3c64xx machines should have a working spi currently.

That reminds me that I have some patches that set the SPI device names and I have been using those for non-dt exynos platform. Yes, it looks like we need a generic function for all Samsung machines that would override SPI device names on all except mach-s3c64xx.

Quoted 1 line

I'm working on a patch to fix this for all Samsung arches.

OK. I have something like this too. Anyway it seems SPI is now broken on all non-dt machines except s3c64xx in kernel 3.6. Perhaps these patches should be also sent now to [email protected].

Regards,
Sylwester

Signature · 2 lines
Sylwester Nawrocki
Samsung Poland R&D Center
#5 lore raw
In reply to Heiko Stübner
Quoted 6 lines · Heiko Stübner

Hi José,

Am Montag, 1. Oktober 2012, 19:32:15 schrieb José Miguel Gonçalves:

Quoted 3 lines

I'm trying to use the HSSPI controller on a S3C2416 based board but I'm having some problems.

Quoted 8 lines
Quoted 6 lines

I've added "&s3c64xx_device_spi0" to my array of platform devices and added a call to s3c64xx_spi0_set_platdata(NULL, 0, 1) before platform_add_devices(). When the kernel starts I see the following error:

s3c64xx-spi s3c6410-spi.0: Unable to acquire clock 'spi'
s3c64xx-spi: probe of s3c6410-spi.0 failed with error -2

what kernel version do you use?

I'm now using kernel 3.6.

José Gonçalves