Hi,

If I have an OSD attached by a FC SAN device with the connection like this:
OSD HBA-->FC Switch-->SAN storage device.

Then Map a LUN in the SAN to the OSD as its only disk device to save data. if I have a client also has an HBA and the topology diagram looks like:

                  osd                                         client
        -------        -------                            -------     
-------
       | HBA |      | NIC |  <---------------> | NIC |   | HBA |
        ---+---      --------                            ------- -------
\                                                            /
                  \ /
                       \                                   /
                              \    --------------
                                  | FC Switch |
                                   --------------
                                          |
                                       SAN

Suppose the created LUN above for OSD can be accessed by both osd and client though FC I/F, the question is:
if I create a rbd block device in osd and map it to client, make a file system and mount it in client side, then create a file in the mounted FS. The read/write operation followed for this file will transfer data though ethernet path or FC path?

BRs,
Dennis

#1 lore raw
Quoted 22 lines · Dennis Chen

Hi,

If I have an OSD attached by a FC SAN device with the connection like this:
OSD HBA-->FC Switch-->SAN storage device.

Then Map a LUN in the SAN to the OSD as its only disk device to save data. if I have a client also has an HBA and the topology diagram looks like:

                   osd                                         client
         -------        -------                            ------- -------
        | HBA |      | NIC |  <---------------> | NIC |   | HBA |
         ---+---      --------                            ------- -------
\                                                            /
                   \ /
                        \                                   /
                               \    --------------
                                   | FC Switch |
                                    --------------
                                           |
                                        SAN
Quoted 7 lines

Suppose the created LUN above for OSD can be accessed by both osd and client though FC I/F, the question is:
if I create a rbd block device in osd and map it to client, make a file system and mount it in client side, then create a file in the mounted FS. The read/write operation followed for this file will transfer data though ethernet path or FC path?

That will follow the Ethernet path.

I'm also trying to figure out why you would Ceph here and use RBD? If the client has direct access to the FC, why not have the client access that direcly?

Ceph makes sense when you are running it on multiple fully separated machines, but not if you run it all one one FC SAN imho.

Wido

Quoted 7 lines

BRs,
Dennis

--