4x write amplification?
Hi,
We did a simple throughput test on Ceph with 2 OSD nodes configured
with one replica policy. For each OSD node, the throughput measured by 'dd' run locally is 117MB/s. Therefore, in theory, the two OSDs could provide 200+MB/s throughput. However, using 'iozone' from clients we only get a peak throughput at around 40MB/s. Is that because a write will incur 2 replica * 2 journal write? That is, writing into journal and replica doubled the traffic, respectively, which results in a total
4x write amplification. Is that true, or our understanding is wrong,
and some performance tuning hint?
Cheers,
Li Wang
Quoted 10 lines · Li Wang
Hi,
We did a simple throughput test on Ceph with 2 OSD nodes configured
with one replica policy. For each OSD node, the throughput measured by 'dd' run locally is 117MB/s. Therefore, in theory, the two OSDs could provide 200+MB/s throughput. However, using 'iozone' from clients we only get a peak throughput at around 40MB/s. Is that because a write will incur 2 replica * 2 journal write? That is, writing into journal
and replica doubled the traffic, respectively, which results in a total 4x write amplification. Is that true, or our understanding is wrong, and some performance tuning hint?
Well, that write amplification is certainly happening. However, I'd expect to get a better ratio out of the disk than that. Couple things to check:
1) is your benchmark dispatching multiple requests at a time, or just one? (the latency on a single request is going to make throughput numbers come out badly.)
2) How do your disks handle two simultaneous write streams? (Most disks should be fine, but sometimes they struggle.)
-Greg
Software Engineer #42 @ http://inktank.com | http://ceph.com
2013/7/10 Gregory Farnum <[email protected]>:
Quoted 12 lines · Li Wang
Quoted 10 lines
Hi,
We did a simple throughput test on Ceph with 2 OSD nodes configured
with one replica policy. For each OSD node, the throughput measured by 'dd' run locally is 117MB/s. Therefore, in theory, the two OSDs could provide 200+MB/s throughput. However, using 'iozone' from clients we only get a peak throughput at around 40MB/s. Is that because a write will incur 2 replica * 2 journal write? That is, writing into journal
and replica doubled the traffic, respectively, which results in a total 4x write amplification. Is that true, or our understanding is wrong, and some performance tuning hint?
Quoted 14 lines
Well, that write amplification is certainly happening. However, I'd expect to get a better ratio out of the disk than that. Couple things to check:
1) is your benchmark dispatching multiple requests at a time, or just one? (the latency on a single request is going to make throughput numbers come out badly.)
2) How do your disks handle two simultaneous write streams? (Most disks should be fine, but sometimes they struggle.)
-Greg
Software Engineer #42 @ http://inktank.com | http://ceph.com
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
I have the same problem:
2 machines with several osds each, default replica count (2), btrfs on osd partitions, default journal location (file on a osd partition), journal size 2Gb, ceph 0.65, 1 Gbit network between machines that is shared with the client.
dd benchmark shows ~ 110 Mb/s on osd partition.
Object write via librados: 1 object - 43 Mb/s, 3 parallel objects - 66 Mb/s. At the same time I monitor osd partitions with iostat. Partitions are loaded 85-110 Mb/s.
If I shutdown one node, write occurs only on one partition on one machine. Same results:
disk is loaded 85-110 Mb/s and I get same throughput on client - 49 Mb/s for single obj and 66 Mb/s for 3 parallel objects.
We are deciding whether to use ceph in production and we are stuck due to our weak understanding of this situation.